Ultrafast X-Ray Detector and its Gain Uniformity

An ultrafast x-ray detector consisted of an electron pulse time-dilation device, a combined electromagnetic lens system, a microchannel plate (MCP) gated imager, and an electrical pulse generator is reported. The time-dilation device is used to magnify the temporal width of the electron beam created...

Full description

Bibliographic Details
Main Authors: Houzhi Cai, Pokun Deng, Wenyong Fu, Dong Wang, Jinyuan Liu
Format: Article
Language:English
Published: IEEE 2019-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8887151/
id doaj-0985df8d9fa14f3b962ab5ffa67aefb6
record_format Article
spelling doaj-0985df8d9fa14f3b962ab5ffa67aefb62021-03-29T23:57:28ZengIEEEIEEE Access2169-35362019-01-01715855715856210.1109/ACCESS.2019.29505568887151Ultrafast X-Ray Detector and its Gain UniformityHouzhi Cai0https://orcid.org/0000-0003-4140-5824Pokun Deng1Wenyong Fu2Dong Wang3Jinyuan Liu4Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, ChinaKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, ChinaKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, ChinaKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, ChinaKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, ChinaAn ultrafast x-ray detector consisted of an electron pulse time-dilation device, a combined electromagnetic lens system, a microchannel plate (MCP) gated imager, and an electrical pulse generator is reported. The time-dilation device is used to magnify the temporal width of the electron beam created from the photo-cathode (PC), and then the combined electromagnetic lens system images the dilated electron beam onto the MCP. Finally, the MCP imager samples the dilated electron signal and outputs corresponding visible light. A measured temporal resolution of 80 ps for the detector is achieved while the electron pulse is not dilated. The resolution is improved to 12 ps while an excitation pulse with 3.1 V/ps rising edge gradient is used to drive the PC to dilate the electron pulse. Moreover, the gain uniformity of the detector is also tested, which shows the gain is decreased gradually with the excitation pulse propagating on the PC and the drop in gain is about 1.7 ×.https://ieeexplore.ieee.org/document/8887151/Gain uniformitypulse-dilationtemporal resolutionx-ray detector
collection DOAJ
language English
format Article
sources DOAJ
author Houzhi Cai
Pokun Deng
Wenyong Fu
Dong Wang
Jinyuan Liu
spellingShingle Houzhi Cai
Pokun Deng
Wenyong Fu
Dong Wang
Jinyuan Liu
Ultrafast X-Ray Detector and its Gain Uniformity
IEEE Access
Gain uniformity
pulse-dilation
temporal resolution
x-ray detector
author_facet Houzhi Cai
Pokun Deng
Wenyong Fu
Dong Wang
Jinyuan Liu
author_sort Houzhi Cai
title Ultrafast X-Ray Detector and its Gain Uniformity
title_short Ultrafast X-Ray Detector and its Gain Uniformity
title_full Ultrafast X-Ray Detector and its Gain Uniformity
title_fullStr Ultrafast X-Ray Detector and its Gain Uniformity
title_full_unstemmed Ultrafast X-Ray Detector and its Gain Uniformity
title_sort ultrafast x-ray detector and its gain uniformity
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2019-01-01
description An ultrafast x-ray detector consisted of an electron pulse time-dilation device, a combined electromagnetic lens system, a microchannel plate (MCP) gated imager, and an electrical pulse generator is reported. The time-dilation device is used to magnify the temporal width of the electron beam created from the photo-cathode (PC), and then the combined electromagnetic lens system images the dilated electron beam onto the MCP. Finally, the MCP imager samples the dilated electron signal and outputs corresponding visible light. A measured temporal resolution of 80 ps for the detector is achieved while the electron pulse is not dilated. The resolution is improved to 12 ps while an excitation pulse with 3.1 V/ps rising edge gradient is used to drive the PC to dilate the electron pulse. Moreover, the gain uniformity of the detector is also tested, which shows the gain is decreased gradually with the excitation pulse propagating on the PC and the drop in gain is about 1.7 ×.
topic Gain uniformity
pulse-dilation
temporal resolution
x-ray detector
url https://ieeexplore.ieee.org/document/8887151/
work_keys_str_mv AT houzhicai ultrafastxraydetectoranditsgainuniformity
AT pokundeng ultrafastxraydetectoranditsgainuniformity
AT wenyongfu ultrafastxraydetectoranditsgainuniformity
AT dongwang ultrafastxraydetectoranditsgainuniformity
AT jinyuanliu ultrafastxraydetectoranditsgainuniformity
_version_ 1724188838091292672