Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open...

Full description

Bibliographic Details
Main Authors: Semra Tiryaki Demir, Mahmut Odabaşı, Mehmet Ersin Oba, Ayşe Burcu Dirim, Efe Can, Orhan Kara
Format: Article
Language:English
Published: Galenos Yayinevi 2014-08-01
Series:Türk Oftalmoloji Dergisi
Subjects:
Online Access:http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-Repeatability
id doaj-327a7a70f39a4ff0ae3cefe8ff79543a
record_format Article
spelling doaj-327a7a70f39a4ff0ae3cefe8ff79543a2020-11-24T22:54:36ZengGalenos YayineviTürk Oftalmoloji Dergisi1300-06592147-26612014-08-0144426326710.4274/tjo.44711Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry RepeatabilitySemra Tiryaki Demir0Mahmut Odabaşı1Mehmet Ersin Oba2Ayşe Burcu Dirim3Efe Can4Orhan Kara5Artvin Devlet Hastanesi, Göz Hastalıkları Kliniği, Artvin, TürkiyeArnavutköy Devlet Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeKafkas Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Kars, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeObjectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000) were used for measurement of CCT. ANOVA (Turkey test) was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p<0.0001). CCT was mean 5.55±8.28 µm thicker by ultrasonic pachymetry compared to corneal topography. There was no significant difference between the two genders (p>0.05). CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001). Repeatability of ultrasonic pachymetry for same observer was (ICC value) 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7)http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-RepeatabilityCentral corneal thicknessultrasonic pachymetryOrbscan II corneal topography
collection DOAJ
language English
format Article
sources DOAJ
author Semra Tiryaki Demir
Mahmut Odabaşı
Mehmet Ersin Oba
Ayşe Burcu Dirim
Efe Can
Orhan Kara
spellingShingle Semra Tiryaki Demir
Mahmut Odabaşı
Mehmet Ersin Oba
Ayşe Burcu Dirim
Efe Can
Orhan Kara
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
Türk Oftalmoloji Dergisi
Central corneal thickness
ultrasonic pachymetry
Orbscan II corneal topography
author_facet Semra Tiryaki Demir
Mahmut Odabaşı
Mehmet Ersin Oba
Ayşe Burcu Dirim
Efe Can
Orhan Kara
author_sort Semra Tiryaki Demir
title Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
title_short Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
title_full Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
title_fullStr Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
title_full_unstemmed Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
title_sort comparison of central corneal thickness measurements by ultrasonic pachymetry and orbscan ii corneal topography and evaluation of ultrasonic pachymetry repeatability
publisher Galenos Yayinevi
series Türk Oftalmoloji Dergisi
issn 1300-0659
2147-2661
publishDate 2014-08-01
description Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000) were used for measurement of CCT. ANOVA (Turkey test) was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p<0.0001). CCT was mean 5.55±8.28 µm thicker by ultrasonic pachymetry compared to corneal topography. There was no significant difference between the two genders (p>0.05). CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001). Repeatability of ultrasonic pachymetry for same observer was (ICC value) 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7)
topic Central corneal thickness
ultrasonic pachymetry
Orbscan II corneal topography
url http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-Repeatability
work_keys_str_mv AT semratiryakidemir comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
AT mahmutodabası comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
AT mehmetersinoba comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
AT ayseburcudirim comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
AT efecan comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
AT orhankara comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability
_version_ 1725658854071468032