Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galenos Yayinevi
2014-08-01
|
Series: | Türk Oftalmoloji Dergisi |
Subjects: | |
Online Access: | http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-Repeatability |
id |
doaj-327a7a70f39a4ff0ae3cefe8ff79543a |
---|---|
record_format |
Article |
spelling |
doaj-327a7a70f39a4ff0ae3cefe8ff79543a2020-11-24T22:54:36ZengGalenos YayineviTürk Oftalmoloji Dergisi1300-06592147-26612014-08-0144426326710.4274/tjo.44711Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry RepeatabilitySemra Tiryaki Demir0Mahmut Odabaşı1Mehmet Ersin Oba2Ayşe Burcu Dirim3Efe Can4Orhan Kara5Artvin Devlet Hastanesi, Göz Hastalıkları Kliniği, Artvin, TürkiyeArnavutköy Devlet Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeKafkas Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Kars, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeŞişli Etfal Eğitim ve Araştırma Hastanesi, Göz Hastalıkları Kliniği, İstanbul, TürkiyeObjectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000) were used for measurement of CCT. ANOVA (Turkey test) was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p<0.0001). CCT was mean 5.55±8.28 µm thicker by ultrasonic pachymetry compared to corneal topography. There was no significant difference between the two genders (p>0.05). CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001). Repeatability of ultrasonic pachymetry for same observer was (ICC value) 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7)http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-RepeatabilityCentral corneal thicknessultrasonic pachymetryOrbscan II corneal topography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Semra Tiryaki Demir Mahmut Odabaşı Mehmet Ersin Oba Ayşe Burcu Dirim Efe Can Orhan Kara |
spellingShingle |
Semra Tiryaki Demir Mahmut Odabaşı Mehmet Ersin Oba Ayşe Burcu Dirim Efe Can Orhan Kara Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability Türk Oftalmoloji Dergisi Central corneal thickness ultrasonic pachymetry Orbscan II corneal topography |
author_facet |
Semra Tiryaki Demir Mahmut Odabaşı Mehmet Ersin Oba Ayşe Burcu Dirim Efe Can Orhan Kara |
author_sort |
Semra Tiryaki Demir |
title |
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability |
title_short |
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability |
title_full |
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability |
title_fullStr |
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability |
title_full_unstemmed |
Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability |
title_sort |
comparison of central corneal thickness measurements by ultrasonic pachymetry and orbscan ii corneal topography and evaluation of ultrasonic pachymetry repeatability |
publisher |
Galenos Yayinevi |
series |
Türk Oftalmoloji Dergisi |
issn |
1300-0659 2147-2661 |
publishDate |
2014-08-01 |
description |
Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography
and evaluation of ultrasonic pachymetry repeatability for same observer.
Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41
patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination.
Orbscan II (Bausch&Lomb) corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000) were used for
measurement of CCT. ANOVA (Turkey test) was used for variable distribution, paired sample t-test was used for repeated measurements,
and the analyses were done by SPSS 20.0.
Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant
difference between the two measurements (p<0.0001). CCT was mean 5.55±8.28 µm thicker by ultrasonic pachymetry compared to
corneal topography. There was no significant difference between the two genders (p>0.05). CCT was 555±39.2 µm, 564.3±28.4 µm,
and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation
between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001). Repeatability of ultrasonic pachymetry
for same observer was (ICC value) 0.990.
Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two
methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography.
Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7) |
topic |
Central corneal thickness ultrasonic pachymetry Orbscan II corneal topography |
url |
http://www.oftalmoloji.org/article_6113/Comparison-Of-Central-Corneal-Thickness-Measurements-By-Ultrasonic-Pachymetry-And-Orbscan-Ii-Corneal-Topography-And-Evaluation-Of-Ultrasonic-Pachymetry-Repeatability |
work_keys_str_mv |
AT semratiryakidemir comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability AT mahmutodabası comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability AT mehmetersinoba comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability AT ayseburcudirim comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability AT efecan comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability AT orhankara comparisonofcentralcornealthicknessmeasurementsbyultrasonicpachymetryandorbscaniicornealtopographyandevaluationofultrasonicpachymetryrepeatability |
_version_ |
1725658854071468032 |