The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve

High precision is necessary during percutaneous transcatheter heart valve implantation. The precision of the implantation has been established by increasing the heart rate (usually to 200 beats per minute) to the point of significantly reduced cardiac output and thus minimizing valve movement. Routi...

Full description

Bibliographic Details
Main Authors: Vicki Zeniou, Shmuel Chen, Mony Shuvy, David Luria, Chaim Lotan, Haim D. Danenberg
Format: Article
Language:English
Published: Hindawi Limited 2017-01-01
Series:Case Reports in Cardiology
Online Access:http://dx.doi.org/10.1155/2017/2760580