A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology

Purpose: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). Methods: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was con...

Full description

Bibliographic Details
Main Authors: Zia S Pradhan, Sujit Deshmukh, Shivani Dixit, Praveena Gudetti, Sathi Devi, Carroll A B Webers, Harsha L Rao
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2020;volume=68;issue=5;spage=787;epage=792;aulast=
id doaj-5d46428046bb422497408e41b8c3b338
record_format Article
spelling doaj-5d46428046bb422497408e41b8c3b3382020-11-25T02:07:42ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892020-01-0168578779210.4103/ijo.IJO_1550_19A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug TechnologyZia S PradhanSujit DeshmukhShivani DixitPraveena GudettiSathi DeviCarroll A B WebersHarsha L RaoPurpose: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). Methods: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was conducted. These included 42 eyes with PXF, 17 eyes of PXF with ocular hypertension (PXF + OHT) defined as intraocular pressure (IOP)> 21 mmHg without disc/field changes, 37 eyes with PXG, and 45 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance, and radius of curvature, were compared among the groups using analysis of variance models. Results: The four groups were demographically similar. The mean IOP was lower in the controls (15.6 ± 3 mmHg) and PXF group (16.0 ± 3 mmHg) compared to the other two groups (>24 mmHg). Corneal pachymetry was similar across the four groups. Mean DA was significantly lower (P < 0.0001) in the PXG group (0.91 ± 0.18 mm) and the PXF + OHT group (0.94 ± 0.13 mm) when compared to the PXF (1.10 ± 0.11 mm) and control groups (1.12 ± 0.14 mm). Corneal velocities were also found to be statistically significantly lower in PXG and PXF + OHT compared to the PXF and control groups. However, after adjusting for age and IOP, there was no difference in any of the biomechanical parameters among the four groups. Conclusion: Corneal biomechanical parameters measured on Corvis ST are not different between healthy controls and eyes with PXF and PXG. Since PXG is a high-pressure glaucoma, corneal biomechanics may not play an important role in its diagnosis and pathogenesis.http://www.ijo.in/article.asp?issn=0301-4738;year=2020;volume=68;issue=5;spage=787;epage=792;aulast=corneal biomechanicscorvis stpseudoexfoliationpseudoexfoliation glaucoma
collection DOAJ
language English
format Article
sources DOAJ
author Zia S Pradhan
Sujit Deshmukh
Shivani Dixit
Praveena Gudetti
Sathi Devi
Carroll A B Webers
Harsha L Rao
spellingShingle Zia S Pradhan
Sujit Deshmukh
Shivani Dixit
Praveena Gudetti
Sathi Devi
Carroll A B Webers
Harsha L Rao
A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
Indian Journal of Ophthalmology
corneal biomechanics
corvis st
pseudoexfoliation
pseudoexfoliation glaucoma
author_facet Zia S Pradhan
Sujit Deshmukh
Shivani Dixit
Praveena Gudetti
Sathi Devi
Carroll A B Webers
Harsha L Rao
author_sort Zia S Pradhan
title A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_short A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_full A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_fullStr A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_full_unstemmed A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology
title_sort comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using corvis® scheimpflug technology
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Ophthalmology
issn 0301-4738
1998-3689
publishDate 2020-01-01
description Purpose: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). Methods: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was conducted. These included 42 eyes with PXF, 17 eyes of PXF with ocular hypertension (PXF + OHT) defined as intraocular pressure (IOP)> 21 mmHg without disc/field changes, 37 eyes with PXG, and 45 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance, and radius of curvature, were compared among the groups using analysis of variance models. Results: The four groups were demographically similar. The mean IOP was lower in the controls (15.6 ± 3 mmHg) and PXF group (16.0 ± 3 mmHg) compared to the other two groups (>24 mmHg). Corneal pachymetry was similar across the four groups. Mean DA was significantly lower (P < 0.0001) in the PXG group (0.91 ± 0.18 mm) and the PXF + OHT group (0.94 ± 0.13 mm) when compared to the PXF (1.10 ± 0.11 mm) and control groups (1.12 ± 0.14 mm). Corneal velocities were also found to be statistically significantly lower in PXG and PXF + OHT compared to the PXF and control groups. However, after adjusting for age and IOP, there was no difference in any of the biomechanical parameters among the four groups. Conclusion: Corneal biomechanical parameters measured on Corvis ST are not different between healthy controls and eyes with PXF and PXG. Since PXG is a high-pressure glaucoma, corneal biomechanics may not play an important role in its diagnosis and pathogenesis.
topic corneal biomechanics
corvis st
pseudoexfoliation
pseudoexfoliation glaucoma
url http://www.ijo.in/article.asp?issn=0301-4738;year=2020;volume=68;issue=5;spage=787;epage=792;aulast=
work_keys_str_mv AT ziaspradhan acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT sujitdeshmukh acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT shivanidixit acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT praveenagudetti acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT sathidevi acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT carrollabwebers acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT harshalrao acomparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT ziaspradhan comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT sujitdeshmukh comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT shivanidixit comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT praveenagudetti comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT sathidevi comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT carrollabwebers comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
AT harshalrao comparisonofthecornealbiomechanicsinpseudoexfoliationsyndromepseudoexfoliationglaucomaandhealthycontrolsusingcorvisscheimpflugtechnology
_version_ 1724930177235943424