Identifying bedrest using 24-h waist or wrist accelerometry in adults.

OBJECTIVES:To adapt and refine a previously-developed youth-specific algorithm to identify bedrest for use in adults. The algorithm is based on using an automated decision tree (DT) analysis of accelerometry data. DESIGN:Healthy adults (n = 141, 85 females, 19-69 years-old) wore accelerometers on th...

Full description

Bibliographic Details
Main Authors: J Dustin Tracy, Sari Acra, Kong Y Chen, Maciej S Buchowski
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5865746?pdf=render
id doaj-7010c080d1444d4a8b1826d21249e381
record_format Article
spelling doaj-7010c080d1444d4a8b1826d21249e3812020-11-24T21:52:12ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01133e019446110.1371/journal.pone.0194461Identifying bedrest using 24-h waist or wrist accelerometry in adults.J Dustin TracySari AcraKong Y ChenMaciej S BuchowskiOBJECTIVES:To adapt and refine a previously-developed youth-specific algorithm to identify bedrest for use in adults. The algorithm is based on using an automated decision tree (DT) analysis of accelerometry data. DESIGN:Healthy adults (n = 141, 85 females, 19-69 years-old) wore accelerometers on the waist, with a subset also wearing accelerometers on the dominant wrist (n = 45). Participants spent ≈24-h in a whole-room indirect calorimeter equipped with a force-platform floor to detect movement. METHODS:Minute-by-minute data from recordings of waist-worn or wrist-worn accelerometers were used to identify bedrest and wake periods. Participants were randomly allocated to development (n = 69 and 23) and validation (n = 72 and 22) groups for waist-worn and wrist-worn accelerometers, respectively. The optimized DT algorithm parameters were block length, threshold, bedrest-start trigger, and bedrest-end trigger. Differences between DT classification and synchronized objective classification by the room calorimeter to bedrest or wake were assessed for sensitivity, specificity, and accuracy using a Receiver Operating Characteristic (ROC) procedure applied to 1-min epochs (n = 92,543 waist; n = 30,653 wrist). RESULTS:The optimal algorithm parameter values for block length were 60 and 45 min, thresholds 12.5 and 400 counts/min, bedrest-start trigger 120 and 400 counts/min, and bedrest-end trigger 1,200 and 1,500 counts/min, for the waist and wrist-worn accelerometers, respectively. Bedrest was identified correctly in the validation group with sensitivities of 0.819 and 0.912, specificities of 0.966 and 0.923, and accuracies of 0.755 and 0.859 by the waist and wrist-worn accelerometer, respectively. The DT algorithm identified bedrest/sleep with greater accuracy than a commonly used automated algorithm (Cole-Kripke) for wrist-worn accelerometers (p<0.001). CONCLUSIONS:The adapted DT accurately identifies bedrest in data from accelerometers worn by adults on either the wrist or waist. The automated bedrest/sleep detection DT algorithm for both youth and adults is openly accessible as a package "PhysActBedRest" for the R-computer language.http://europepmc.org/articles/PMC5865746?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author J Dustin Tracy
Sari Acra
Kong Y Chen
Maciej S Buchowski
spellingShingle J Dustin Tracy
Sari Acra
Kong Y Chen
Maciej S Buchowski
Identifying bedrest using 24-h waist or wrist accelerometry in adults.
PLoS ONE
author_facet J Dustin Tracy
Sari Acra
Kong Y Chen
Maciej S Buchowski
author_sort J Dustin Tracy
title Identifying bedrest using 24-h waist or wrist accelerometry in adults.
title_short Identifying bedrest using 24-h waist or wrist accelerometry in adults.
title_full Identifying bedrest using 24-h waist or wrist accelerometry in adults.
title_fullStr Identifying bedrest using 24-h waist or wrist accelerometry in adults.
title_full_unstemmed Identifying bedrest using 24-h waist or wrist accelerometry in adults.
title_sort identifying bedrest using 24-h waist or wrist accelerometry in adults.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2018-01-01
description OBJECTIVES:To adapt and refine a previously-developed youth-specific algorithm to identify bedrest for use in adults. The algorithm is based on using an automated decision tree (DT) analysis of accelerometry data. DESIGN:Healthy adults (n = 141, 85 females, 19-69 years-old) wore accelerometers on the waist, with a subset also wearing accelerometers on the dominant wrist (n = 45). Participants spent ≈24-h in a whole-room indirect calorimeter equipped with a force-platform floor to detect movement. METHODS:Minute-by-minute data from recordings of waist-worn or wrist-worn accelerometers were used to identify bedrest and wake periods. Participants were randomly allocated to development (n = 69 and 23) and validation (n = 72 and 22) groups for waist-worn and wrist-worn accelerometers, respectively. The optimized DT algorithm parameters were block length, threshold, bedrest-start trigger, and bedrest-end trigger. Differences between DT classification and synchronized objective classification by the room calorimeter to bedrest or wake were assessed for sensitivity, specificity, and accuracy using a Receiver Operating Characteristic (ROC) procedure applied to 1-min epochs (n = 92,543 waist; n = 30,653 wrist). RESULTS:The optimal algorithm parameter values for block length were 60 and 45 min, thresholds 12.5 and 400 counts/min, bedrest-start trigger 120 and 400 counts/min, and bedrest-end trigger 1,200 and 1,500 counts/min, for the waist and wrist-worn accelerometers, respectively. Bedrest was identified correctly in the validation group with sensitivities of 0.819 and 0.912, specificities of 0.966 and 0.923, and accuracies of 0.755 and 0.859 by the waist and wrist-worn accelerometer, respectively. The DT algorithm identified bedrest/sleep with greater accuracy than a commonly used automated algorithm (Cole-Kripke) for wrist-worn accelerometers (p<0.001). CONCLUSIONS:The adapted DT accurately identifies bedrest in data from accelerometers worn by adults on either the wrist or waist. The automated bedrest/sleep detection DT algorithm for both youth and adults is openly accessible as a package "PhysActBedRest" for the R-computer language.
url http://europepmc.org/articles/PMC5865746?pdf=render
work_keys_str_mv AT jdustintracy identifyingbedrestusing24hwaistorwristaccelerometryinadults
AT sariacra identifyingbedrestusing24hwaistorwristaccelerometryinadults
AT kongychen identifyingbedrestusing24hwaistorwristaccelerometryinadults
AT maciejsbuchowski identifyingbedrestusing24hwaistorwristaccelerometryinadults
_version_ 1725876318317314048