Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel

Artykuł opisuje wpływ dodatku niklu| do stopów wtórnych Al-Si-Cu na segregację faz zawierających żelazo, które jest jednym z najpowszechniej występujących zanieczyszczeń w tych stopach. Powszechnie wiadomo, iż nie jest możliwe usunięcie żelaza z kąpieli metalowej, natomiast można ograniczać negatyw...

Full description

Bibliographic Details
Main Authors: Bolibruchová D., Macko J., Brůna M.
Format: Article
Language:English
Published: Polish Academy of Sciences 2014-06-01
Series:Archives of Metallurgy and Materials
Subjects:
Online Access:http://www.degruyter.com/view/j/amm.2014.59.issue-2/amm-2014-0118/amm-2014-0118.xml?format=INT
id doaj-7f4e5f4c13e940e3baee908c6bca4300
record_format Article
spelling doaj-7f4e5f4c13e940e3baee908c6bca43002020-11-25T03:44:35ZengPolish Academy of SciencesArchives of Metallurgy and Materials2300-19092014-06-0159271772110.2478/amm-2014-0118amm-2014-0118Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by NickelBolibruchová D.0Macko J.1Brůna M.2UNIVERSITY OF ŽILINA, FACULTY OF MECHANICAL ENGINEERING, DEPARTMENT OF TECHNOLOGICAL ENGINEERING, SLOVAK REPUBLICUNIVERSITY OF ŽILINA, FACULTY OF MECHANICAL ENGINEERING, DEPARTMENT OF TECHNOLOGICAL ENGINEERING, SLOVAK REPUBLICUNIVERSITY OF ŽILINA, FACULTY OF MECHANICAL ENGINEERING, DEPARTMENT OF TECHNOLOGICAL ENGINEERING, SLOVAK REPUBLIC Artykuł opisuje wpływ dodatku niklu| do stopów wtórnych Al-Si-Cu na segregację faz zawierających żelazo, które jest jednym z najpowszechniej występujących zanieczyszczeń w tych stopach. Powszechnie wiadomo, iż nie jest możliwe usunięcie żelaza z kąpieli metalowej, natomiast można ograniczać negatywny jego wpływ poprzez związanie żelaza w fazach między- metalicznych mniej szkodliwych niż fazy β Fe, np. w następstwie dodatku innych pierwiastków. W badaniach do obróbki kąpieli zastosowano zaprawę AlNi20 z dokładnie określoną zawartością żelaza. Oddziały wanie niklu na skład i morfologię faz żelazowych określano na drodze analizy chemicznej (badania rozpuszczalności), analizy termicznej i oceny struktury. Na podstawie wyników badań stwierdzono, iż w badanych stopach nikiel nie wywiera wpływu na zmianę składu fazy (Z Fe, nie zmienia również kształtu jej wydzieleń do postaci bardziej korzystnej z punktu widzenia wpływu na właściwości.http://www.degruyter.com/view/j/amm.2014.59.issue-2/amm-2014-0118/amm-2014-0118.xml?format=INTIron based phasesthermal analysisiron based phases correctorsnickel
collection DOAJ
language English
format Article
sources DOAJ
author Bolibruchová D.
Macko J.
Brůna M.
spellingShingle Bolibruchová D.
Macko J.
Brůna M.
Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
Archives of Metallurgy and Materials
Iron based phases
thermal analysis
iron based phases correctors
nickel
author_facet Bolibruchová D.
Macko J.
Brůna M.
author_sort Bolibruchová D.
title Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
title_short Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
title_full Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
title_fullStr Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
title_full_unstemmed Elimination of Negative Effect of Fe in Secondary Alloys AlSi6Cu4 (En Ac 45 000, A 319) by Nickel
title_sort elimination of negative effect of fe in secondary alloys alsi6cu4 (en ac 45 000, a 319) by nickel
publisher Polish Academy of Sciences
series Archives of Metallurgy and Materials
issn 2300-1909
publishDate 2014-06-01
description Artykuł opisuje wpływ dodatku niklu| do stopów wtórnych Al-Si-Cu na segregację faz zawierających żelazo, które jest jednym z najpowszechniej występujących zanieczyszczeń w tych stopach. Powszechnie wiadomo, iż nie jest możliwe usunięcie żelaza z kąpieli metalowej, natomiast można ograniczać negatywny jego wpływ poprzez związanie żelaza w fazach między- metalicznych mniej szkodliwych niż fazy β Fe, np. w następstwie dodatku innych pierwiastków. W badaniach do obróbki kąpieli zastosowano zaprawę AlNi20 z dokładnie określoną zawartością żelaza. Oddziały wanie niklu na skład i morfologię faz żelazowych określano na drodze analizy chemicznej (badania rozpuszczalności), analizy termicznej i oceny struktury. Na podstawie wyników badań stwierdzono, iż w badanych stopach nikiel nie wywiera wpływu na zmianę składu fazy (Z Fe, nie zmienia również kształtu jej wydzieleń do postaci bardziej korzystnej z punktu widzenia wpływu na właściwości.
topic Iron based phases
thermal analysis
iron based phases correctors
nickel
url http://www.degruyter.com/view/j/amm.2014.59.issue-2/amm-2014-0118/amm-2014-0118.xml?format=INT
work_keys_str_mv AT bolibruchovad eliminationofnegativeeffectoffeinsecondaryalloysalsi6cu4enac45000a319bynickel
AT mackoj eliminationofnegativeeffectoffeinsecondaryalloysalsi6cu4enac45000a319bynickel
AT brunam eliminationofnegativeeffectoffeinsecondaryalloysalsi6cu4enac45000a319bynickel
_version_ 1724513876423213056