Performance analysis and comparison of PMSM with concentrated winding and distributed winding

The concentrated winding (CW) is obviously different from the traditional distributed winding (DW) in the arrangement of windings and the calculation of winding factors, which will inevitably lead to different performances of the permanent magnet synchronous motor (PMSM). In order to analyze the dif...

Full description

Bibliographic Details
Main Authors: Hongbo Qiu, Yong Zhang, Cunxiang Yang, Ran Yi
Format: Article
Language:English
Published: Polish Academy of Sciences 2020-06-01
Series:Archives of Electrical Engineering
Subjects:
Online Access:https://journals.pan.pl/dlibra/publication/133027/edition/116227/content
id doaj-8bfc5d9e614f420db5edea9b3750850f
record_format Article
spelling doaj-8bfc5d9e614f420db5edea9b3750850f2020-11-25T03:31:11ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062020-06-0169230331710.24425/aee.2020.133027Performance analysis and comparison of PMSM with concentrated winding and distributed winding Hongbo Qiu0 Yong Zhang1https://orcid.org/0000-0002-0659-7843Cunxiang Yang2Ran Yi3School of Electrical and Information Engineering Zhengzhou University of Light Industry No. 5 Dongfeng Road, Zhengzhou, Henan province, China, 450002School of Electrical and Information Engineering Zhengzhou University of Light Industry No. 5 Dongfeng Road, Zhengzhou, Henan province, China, 450002School of Electrical and Information Engineering Zhengzhou University of Light Industry No. 5 Dongfeng Road, Zhengzhou, Henan province, China, 450002School of Electrical and Information Engineering Zhengzhou University of Light Industry No. 5 Dongfeng Road, Zhengzhou, Henan province, China, 450002The concentrated winding (CW) is obviously different from the traditional distributed winding (DW) in the arrangement of windings and the calculation of winding factors, which will inevitably lead to different performances of the permanent magnet synchronous motor (PMSM). In order to analyze the differences between the CW and the DW in the performance, a 3 kW, 1500 r/min PMSM is taken as an example to establish a 2-D finite element model. The correctness of the model is verified by comparing experimental data and calculated data. Firstly, the finite element method (FEM) is used to calculate the electromagnetic field of the PMSM, and the performance parameters of the PMSM are obtained. On this basis, the influences of the two winding structures on the performance are quantitatively analyzed, and the differences between the two winding structures on the performance of the PMSM will be determined. Finally, the differences of efficiency between the two winding structures are obtained. In addition, the influences of the winding structures on eddy current loss are further studied, and the mechanism of eddy current loss is revealed by studying the eddy current density. The analysis of this paper provides reference and practical value for the optimization design of the PMSM.https://journals.pan.pl/dlibra/publication/133027/edition/116227/contentair-gap flux densitycogging torqueconcentrated windingdistributed windingefficiencylosspmsm
collection DOAJ
language English
format Article
sources DOAJ
author Hongbo Qiu
Yong Zhang
Cunxiang Yang
Ran Yi
spellingShingle Hongbo Qiu
Yong Zhang
Cunxiang Yang
Ran Yi
Performance analysis and comparison of PMSM with concentrated winding and distributed winding
Archives of Electrical Engineering
air-gap flux density
cogging torque
concentrated winding
distributed winding
efficiency
loss
pmsm
author_facet Hongbo Qiu
Yong Zhang
Cunxiang Yang
Ran Yi
author_sort Hongbo Qiu
title Performance analysis and comparison of PMSM with concentrated winding and distributed winding
title_short Performance analysis and comparison of PMSM with concentrated winding and distributed winding
title_full Performance analysis and comparison of PMSM with concentrated winding and distributed winding
title_fullStr Performance analysis and comparison of PMSM with concentrated winding and distributed winding
title_full_unstemmed Performance analysis and comparison of PMSM with concentrated winding and distributed winding
title_sort performance analysis and comparison of pmsm with concentrated winding and distributed winding
publisher Polish Academy of Sciences
series Archives of Electrical Engineering
issn 2300-2506
publishDate 2020-06-01
description The concentrated winding (CW) is obviously different from the traditional distributed winding (DW) in the arrangement of windings and the calculation of winding factors, which will inevitably lead to different performances of the permanent magnet synchronous motor (PMSM). In order to analyze the differences between the CW and the DW in the performance, a 3 kW, 1500 r/min PMSM is taken as an example to establish a 2-D finite element model. The correctness of the model is verified by comparing experimental data and calculated data. Firstly, the finite element method (FEM) is used to calculate the electromagnetic field of the PMSM, and the performance parameters of the PMSM are obtained. On this basis, the influences of the two winding structures on the performance are quantitatively analyzed, and the differences between the two winding structures on the performance of the PMSM will be determined. Finally, the differences of efficiency between the two winding structures are obtained. In addition, the influences of the winding structures on eddy current loss are further studied, and the mechanism of eddy current loss is revealed by studying the eddy current density. The analysis of this paper provides reference and practical value for the optimization design of the PMSM.
topic air-gap flux density
cogging torque
concentrated winding
distributed winding
efficiency
loss
pmsm
url https://journals.pan.pl/dlibra/publication/133027/edition/116227/content
work_keys_str_mv AT hongboqiu performanceanalysisandcomparisonofpmsmwithconcentratedwindinganddistributedwinding
AT yongzhang performanceanalysisandcomparisonofpmsmwithconcentratedwindinganddistributedwinding
AT cunxiangyang performanceanalysisandcomparisonofpmsmwithconcentratedwindinganddistributedwinding
AT ranyi performanceanalysisandcomparisonofpmsmwithconcentratedwindinganddistributedwinding
_version_ 1724573045796896768