Clinical application of chromosomal microarray analysis in fetuses with increased nuchal translucency and normal karyotype

Abstract Background Submicroscopic chromosomal imbalance is associated with an increased nuchal translucency (NT). Most previous research has recommended the use of chromosomal microarray analysis (CMA) for prenatal diagnosis if the NT ≥ 3.5 mm. However, there is no current global consensus on the c...

Full description

Bibliographic Details
Main Authors: Linjuan Su, Hailong Huang, Gang An, Meiying Cai, Xiaoqing Wu, Ying Li, Xiaorui Xie, Yuan Lin, Meiying Wang, Liangpu Xu
Format: Article
Language:English
Published: Wiley 2019-08-01
Series:Molecular Genetics & Genomic Medicine
Subjects:
Online Access:https://doi.org/10.1002/mgg3.811
Description
Summary:Abstract Background Submicroscopic chromosomal imbalance is associated with an increased nuchal translucency (NT). Most previous research has recommended the use of chromosomal microarray analysis (CMA) for prenatal diagnosis if the NT ≥ 3.5 mm. However, there is no current global consensus on the cutoff value for CMA. In this study, we aimed to discuss the fetuses with smaller increased NT which was between cutoff value of NT for karyotype analysis (NT of 2.5 mm in China) and the recommended cutoff value for CMA (NT of 3.5 mm) whether should be excluded from CMA test. Methods Singleton pregnant women (N = 192) who had undergone invasive procedures owing to an increased NT (NT ≥ 2.5 mm) were enrolled. Fetal cells were collected and subjected to single nucleotide polymorphism array and karyotype analyses simultaneously. Cases were excluded if the karyotype analysis indicated aneuploidy and apparent structural aberrations. Results Fourteen cases of aneuploidy and four cases of structural abnormalities were excluded. Of the remaining 174 cases, 119 fetuses had NTs of 2.5–3.4 mm, and 55 fetuses with NT ≥ 3.5 mm. Eleven copy number variants (CNVs) were identified. In fetuses with smaller NTs, six (6/119, 5.9%) variations were detected, including two (2/119, 1.6%) clinically significant CNVs (pathogenic or likely pathogenic CNV), one  likely benign CNV, two variants unknown significance, and one incidental CNV. Five (5/55, 9.1%) variations were found in fetuses with NT ≥ 3.5 mm. Among these CNVs, three (3/55, 5.5%) cases had clinically significant CNVs, and two had likely benign CNV. There were no statistically significant differences in the incidence of all CNVs and clinically significant CNVs in the two groups (p > 0.05). Conclusion CMA improved the diagnostic yield of chromosomal aberrations for fetuses with NTs of 2.5–3.4 mm and apparently normal karyotype, regardless of whether other ultrasonic abnormalities were observed.
ISSN:2324-9269