Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran
Objectives: To monitor the corneal thickness change during the dextran-free isotonic riboflavin solution-aided corneal collagen crosslinking procedure in keratoconus patients. Materials and Methods: Corneal thickness measurements during the corneal collagen cross-linking (CXL) treatment for progre...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galenos Yayinevi
2014-08-01
|
Series: | Türk Oftalmoloji Dergisi |
Subjects: | |
Online Access: | http://www.oftalmoloji.org/article_6115/Corneal-Thickness-During-Corneal-Collagen-Cross-linking-With-Isotonic-Riboflavin-Solution-Without-Dextran |
id |
doaj-9b3c03fe42c04f9389ad8d59869b612a |
---|---|
record_format |
Article |
spelling |
doaj-9b3c03fe42c04f9389ad8d59869b612a2020-11-24T23:25:23ZengGalenos YayineviTürk Oftalmoloji Dergisi1300-06592147-26612014-08-0144427227410.4274/tjo.08831Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without DextranRefik Oltulu0Meryem Donbaloğlu1 Günhal Şatırtav2 Nazmi Zengin3Ahmet Özkağnıcı4Necmettin Erbakan Üniversitesi Meram Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Konya, TürkiyeNecmettin Erbakan Üniversitesi Meram Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Konya, TürkiyeNecmettin Erbakan Üniversitesi Meram Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Konya, TürkiyeNecmettin Erbakan Üniversitesi Meram Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Konya, TürkiyeNecmettin Erbakan Üniversitesi Meram Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Konya, TürkiyeObjectives: To monitor the corneal thickness change during the dextran-free isotonic riboflavin solution-aided corneal collagen crosslinking procedure in keratoconus patients. Materials and Methods: Corneal thickness measurements during the corneal collagen cross-linking (CXL) treatment for progressive keratoconus were evaluated. The corneal thickness measurements were obtained with ultrasonic pachymetry device at five different time points: 0, 15, and 30 minutes after epithelial removal and 15 and 30 minutes after the initiation of UVA irradiation. Results: Twenty-four eyes of 24 patients with progressive keratoconus were included in the study. The thinnest pachymetric values obtained at the 0, 15, and 30 minute measurements after corneal deepithelisation were 409.38±10.43 µm (383-435 µm), 434.56±17.68 µm (400-485 µm), and 457.44±21.78 µm (428-516 µm), respectively. Pachymetric values obtained at 15 and 30 minutes after UVA application to the cornea were 471.69±23.38 µm (439-526 µm) and 482.63±23.69 µm (436-524 µm), respectively. The gradual increase was found to be statistically significant when each measurement was compared with the previous values (p<0.001). Conclusion: We found that the corneal thickness was not decreased during the CXL with dextran-free isotonic riboflavin solution; on the contrary, corneal thickness was increased regularly during the procedure. (Turk J Ophthalmol 2014; 44: 272-4)http://www.oftalmoloji.org/article_6115/Corneal-Thickness-During-Corneal-Collagen-Cross-linking-With-Isotonic-Riboflavin-Solution-Without-DextranKeratoconuscollagen cross-linkingcorneal thickness |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Refik Oltulu Meryem Donbaloğlu Günhal Şatırtav Nazmi Zengin Ahmet Özkağnıcı |
spellingShingle |
Refik Oltulu Meryem Donbaloğlu Günhal Şatırtav Nazmi Zengin Ahmet Özkağnıcı Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran Türk Oftalmoloji Dergisi Keratoconus collagen cross-linking corneal thickness |
author_facet |
Refik Oltulu Meryem Donbaloğlu Günhal Şatırtav Nazmi Zengin Ahmet Özkağnıcı |
author_sort |
Refik Oltulu |
title |
Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran |
title_short |
Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran |
title_full |
Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran |
title_fullStr |
Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran |
title_full_unstemmed |
Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran |
title_sort |
corneal thickness during corneal collagen cross-linking with isotonic riboflavin solution without dextran |
publisher |
Galenos Yayinevi |
series |
Türk Oftalmoloji Dergisi |
issn |
1300-0659 2147-2661 |
publishDate |
2014-08-01 |
description |
Objectives: To monitor the corneal thickness change during the dextran-free isotonic riboflavin solution-aided corneal collagen crosslinking
procedure in keratoconus patients.
Materials and Methods: Corneal thickness measurements during the corneal collagen cross-linking (CXL) treatment for progressive
keratoconus were evaluated. The corneal thickness measurements were obtained with ultrasonic pachymetry device at five different time
points: 0, 15, and 30 minutes after epithelial removal and 15 and 30 minutes after the initiation of UVA irradiation.
Results: Twenty-four eyes of 24 patients with progressive keratoconus were included in the study. The thinnest pachymetric values
obtained at the 0, 15, and 30 minute measurements after corneal deepithelisation were 409.38±10.43 µm (383-435 µm), 434.56±17.68
µm (400-485 µm), and 457.44±21.78 µm (428-516 µm), respectively. Pachymetric values obtained at 15 and 30 minutes after UVA
application to the cornea were 471.69±23.38 µm (439-526 µm) and 482.63±23.69 µm (436-524 µm), respectively. The gradual increase
was found to be statistically significant when each measurement was compared with the previous values (p<0.001).
Conclusion: We found that the corneal thickness was not decreased during the CXL with dextran-free isotonic riboflavin solution; on
the contrary, corneal thickness was increased regularly during the procedure. (Turk J Ophthalmol 2014; 44: 272-4) |
topic |
Keratoconus collagen cross-linking corneal thickness |
url |
http://www.oftalmoloji.org/article_6115/Corneal-Thickness-During-Corneal-Collagen-Cross-linking-With-Isotonic-Riboflavin-Solution-Without-Dextran |
work_keys_str_mv |
AT refikoltulu cornealthicknessduringcornealcollagencrosslinkingwithisotonicriboflavinsolutionwithoutdextran AT meryemdonbaloglu cornealthicknessduringcornealcollagencrosslinkingwithisotonicriboflavinsolutionwithoutdextran AT gunhalsatırtav cornealthicknessduringcornealcollagencrosslinkingwithisotonicriboflavinsolutionwithoutdextran AT nazmizengin cornealthicknessduringcornealcollagencrosslinkingwithisotonicriboflavinsolutionwithoutdextran AT ahmetozkagnıcı cornealthicknessduringcornealcollagencrosslinkingwithisotonicriboflavinsolutionwithoutdextran |
_version_ |
1725557785929711616 |