In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth
Aim: To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 pri...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2014-01-01
|
Series: | Indian Journal of Dental Research |
Subjects: | |
Online Access: | http://www.ijdr.in/article.asp?issn=0970-9290;year=2014;volume=25;issue=6;spage=702;epage=710;aulast=de |
id |
doaj-a3aa4c86f7e54a8eb9aeefac2a9411ac |
---|---|
record_format |
Article |
spelling |
doaj-a3aa4c86f7e54a8eb9aeefac2a9411ac2020-11-25T00:24:13ZengWolters Kluwer Medknow PublicationsIndian Journal of Dental Research0970-92901998-36032014-01-0125670271010.4103/0970-9290.152165In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teethJuliana Feltrin de SouzaMichele Baffi DinizThalita BoldieriJonas Almeida RodriguesAdrian LussiRita de Cássia Loiola CordeiroAim: To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen′s weighted kappa values. Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.http://www.ijdr.in/article.asp?issn=0970-9290;year=2014;volume=25;issue=6;spage=702;epage=710;aulast=deApproximal cariescaries detectionfluorescenceradiography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Juliana Feltrin de Souza Michele Baffi Diniz Thalita Boldieri Jonas Almeida Rodrigues Adrian Lussi Rita de Cássia Loiola Cordeiro |
spellingShingle |
Juliana Feltrin de Souza Michele Baffi Diniz Thalita Boldieri Jonas Almeida Rodrigues Adrian Lussi Rita de Cássia Loiola Cordeiro In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth Indian Journal of Dental Research Approximal caries caries detection fluorescence radiography |
author_facet |
Juliana Feltrin de Souza Michele Baffi Diniz Thalita Boldieri Jonas Almeida Rodrigues Adrian Lussi Rita de Cássia Loiola Cordeiro |
author_sort |
Juliana Feltrin de Souza |
title |
In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
title_short |
In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
title_full |
In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
title_fullStr |
In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
title_full_unstemmed |
In vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
title_sort |
in vitro performance of a pen-type laser fluorescence device and bitewing radiographs for approximal caries detection in permanent and primary teeth |
publisher |
Wolters Kluwer Medknow Publications |
series |
Indian Journal of Dental Research |
issn |
0970-9290 1998-3603 |
publishDate |
2014-01-01 |
description |
Aim: To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth.
Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and
permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen′s weighted kappa values.
Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW)
for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth.
Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection. |
topic |
Approximal caries caries detection fluorescence radiography |
url |
http://www.ijdr.in/article.asp?issn=0970-9290;year=2014;volume=25;issue=6;spage=702;epage=710;aulast=de |
work_keys_str_mv |
AT julianafeltrindesouza invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth AT michelebaffidiniz invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth AT thalitaboldieri invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth AT jonasalmeidarodrigues invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth AT adrianlussi invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth AT ritadecassialoiolacordeiro invitroperformanceofapentypelaserfluorescencedeviceandbitewingradiographsforapproximalcariesdetectioninpermanentandprimaryteeth |