METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS

The method of identification of the water vapour permeability resistance of finishing layers of composite thermal insulation facade systems that have thin external plaster layers was developed by the authors. The above systems comprise one layer of the heat insulation material that has a 5 mm finish...

Full description

Bibliographic Details
Main Authors: Gagarin Vladimir Gennadevich, Pastushkov Pavel Pavlovich
Format: Article
Language:English
Published: Moscow State University of Civil Engineering (MGSU) 2012-12-01
Series:Vestnik MGSU
Subjects:
Online Access:http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdf
id doaj-b1b75599dedf4f1cba012f500ff1d695
record_format Article
spelling doaj-b1b75599dedf4f1cba012f500ff1d6952020-11-24T23:06:24ZengMoscow State University of Civil Engineering (MGSU)Vestnik MGSU 1997-09352012-12-0111140143METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERSGagarin Vladimir Gennadevich0Pastushkov Pavel Pavlovich1Moscow State University of Civil Engineering (MGSU)Research Institute of Building Physics of Russian Academy of Architectural and Construction Sciences (RAACS)The method of identification of the water vapour permeability resistance of finishing layers of composite thermal insulation facade systems that have thin external plaster layers was developed by the authors. The above systems comprise one layer of the heat insulation material that has a 5 mm finishing coating. This system is fastened to the building wall. The method is based on the results of an experiment held to identify the resistance of all systems to the water vapour permeability irrespective of the availability of finishing layers. The proposed method is more accurate than any of the previously known methods that contemplate the experimental determination of coefficients of water vapour permeability of materials of finishing layers and subsequent calculation of the overall resistance to the water vapour. The State Standard «Method of Determination of Resistance to the Water Vapour Permeability» that implements the «wet cup» technology has been applied. The method has been employed to identify the resistance of finishing layers of BAUMIT insulation system to the water vapour permeability. BAUMIT has a thermal insulation layer made of mineral cotton. It has been identified that the overall resistance of the finishing layer to the water vapour permeability, as determined in accordance with the methodology developed by the authors, is twice as less efficient than the overall resistance identified in accordance with prior methodologies. This difference in the characteristics of finishing layers essentially raises the accuracy of projections of the moisture behaviour of all composite facade insulation systems that have thin external plaster layers.http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdfthermal insulation systemscoeffi cient of water vapour permeabilityresistance to water vapour permeabilityfinishing layers
collection DOAJ
language English
format Article
sources DOAJ
author Gagarin Vladimir Gennadevich
Pastushkov Pavel Pavlovich
spellingShingle Gagarin Vladimir Gennadevich
Pastushkov Pavel Pavlovich
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
Vestnik MGSU
thermal insulation systems
coeffi cient of water vapour permeability
resistance to water vapour permeability
finishing layers
author_facet Gagarin Vladimir Gennadevich
Pastushkov Pavel Pavlovich
author_sort Gagarin Vladimir Gennadevich
title METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
title_short METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
title_full METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
title_fullStr METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
title_full_unstemmed METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
title_sort methodology of identification of the overall water vapour permeability resistance of external finishing layers of composite thermal insulation façade systems that have external plaster layers
publisher Moscow State University of Civil Engineering (MGSU)
series Vestnik MGSU
issn 1997-0935
publishDate 2012-12-01
description The method of identification of the water vapour permeability resistance of finishing layers of composite thermal insulation facade systems that have thin external plaster layers was developed by the authors. The above systems comprise one layer of the heat insulation material that has a 5 mm finishing coating. This system is fastened to the building wall. The method is based on the results of an experiment held to identify the resistance of all systems to the water vapour permeability irrespective of the availability of finishing layers. The proposed method is more accurate than any of the previously known methods that contemplate the experimental determination of coefficients of water vapour permeability of materials of finishing layers and subsequent calculation of the overall resistance to the water vapour. The State Standard «Method of Determination of Resistance to the Water Vapour Permeability» that implements the «wet cup» technology has been applied. The method has been employed to identify the resistance of finishing layers of BAUMIT insulation system to the water vapour permeability. BAUMIT has a thermal insulation layer made of mineral cotton. It has been identified that the overall resistance of the finishing layer to the water vapour permeability, as determined in accordance with the methodology developed by the authors, is twice as less efficient than the overall resistance identified in accordance with prior methodologies. This difference in the characteristics of finishing layers essentially raises the accuracy of projections of the moisture behaviour of all composite facade insulation systems that have thin external plaster layers.
topic thermal insulation systems
coeffi cient of water vapour permeability
resistance to water vapour permeability
finishing layers
url http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdf
work_keys_str_mv AT gagarinvladimirgennadevich methodologyofidentificationoftheoverallwatervapourpermeabilityresistanceofexternalfinishinglayersofcompositethermalinsulationfacadesystemsthathaveexternalplasterlayers
AT pastushkovpavelpavlovich methodologyofidentificationoftheoverallwatervapourpermeabilityresistanceofexternalfinishinglayersofcompositethermalinsulationfacadesystemsthathaveexternalplasterlayers
_version_ 1725623279727673344