METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS
The method of identification of the water vapour permeability resistance of finishing layers of composite thermal insulation facade systems that have thin external plaster layers was developed by the authors. The above systems comprise one layer of the heat insulation material that has a 5 mm finish...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Moscow State University of Civil Engineering (MGSU)
2012-12-01
|
Series: | Vestnik MGSU |
Subjects: | |
Online Access: | http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdf |
id |
doaj-b1b75599dedf4f1cba012f500ff1d695 |
---|---|
record_format |
Article |
spelling |
doaj-b1b75599dedf4f1cba012f500ff1d6952020-11-24T23:06:24ZengMoscow State University of Civil Engineering (MGSU)Vestnik MGSU 1997-09352012-12-0111140143METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERSGagarin Vladimir Gennadevich0Pastushkov Pavel Pavlovich1Moscow State University of Civil Engineering (MGSU)Research Institute of Building Physics of Russian Academy of Architectural and Construction Sciences (RAACS)The method of identification of the water vapour permeability resistance of finishing layers of composite thermal insulation facade systems that have thin external plaster layers was developed by the authors. The above systems comprise one layer of the heat insulation material that has a 5 mm finishing coating. This system is fastened to the building wall. The method is based on the results of an experiment held to identify the resistance of all systems to the water vapour permeability irrespective of the availability of finishing layers. The proposed method is more accurate than any of the previously known methods that contemplate the experimental determination of coefficients of water vapour permeability of materials of finishing layers and subsequent calculation of the overall resistance to the water vapour. The State Standard «Method of Determination of Resistance to the Water Vapour Permeability» that implements the «wet cup» technology has been applied. The method has been employed to identify the resistance of finishing layers of BAUMIT insulation system to the water vapour permeability. BAUMIT has a thermal insulation layer made of mineral cotton. It has been identified that the overall resistance of the finishing layer to the water vapour permeability, as determined in accordance with the methodology developed by the authors, is twice as less efficient than the overall resistance identified in accordance with prior methodologies. This difference in the characteristics of finishing layers essentially raises the accuracy of projections of the moisture behaviour of all composite facade insulation systems that have thin external plaster layers.http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdfthermal insulation systemscoeffi cient of water vapour permeabilityresistance to water vapour permeabilityfinishing layers |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gagarin Vladimir Gennadevich Pastushkov Pavel Pavlovich |
spellingShingle |
Gagarin Vladimir Gennadevich Pastushkov Pavel Pavlovich METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS Vestnik MGSU thermal insulation systems coeffi cient of water vapour permeability resistance to water vapour permeability finishing layers |
author_facet |
Gagarin Vladimir Gennadevich Pastushkov Pavel Pavlovich |
author_sort |
Gagarin Vladimir Gennadevich |
title |
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY
RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION
FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS |
title_short |
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY
RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION
FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS |
title_full |
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY
RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION
FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS |
title_fullStr |
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY
RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION
FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS |
title_full_unstemmed |
METHODOLOGY OF IDENTIFICATION OF THE OVERALL WATER VAPOUR PERMEABILITY
RESISTANCE OF EXTERNAL FINISHING LAYERS OF COMPOSITE THERMAL INSULATION
FAÇADE SYSTEMS THAT HAVE EXTERNAL PLASTER LAYERS |
title_sort |
methodology of identification of the overall water vapour permeability
resistance of external finishing layers of composite thermal insulation
façade systems that have external plaster layers |
publisher |
Moscow State University of Civil Engineering (MGSU) |
series |
Vestnik MGSU |
issn |
1997-0935 |
publishDate |
2012-12-01 |
description |
The method of identification of the water vapour permeability resistance of finishing layers of
composite thermal insulation facade systems that have thin external plaster layers was developed
by the authors. The above systems comprise one layer of the heat insulation material that has a 5
mm finishing coating. This system is fastened to the building wall. The method is based on the results
of an experiment held to identify the resistance of all systems to the water vapour permeability
irrespective of the availability of finishing layers.
The proposed method is more accurate than any of the previously known methods that contemplate
the experimental determination of coefficients of water vapour permeability of materials
of finishing layers and subsequent calculation of the overall resistance to the water vapour. The
State Standard «Method of Determination of Resistance to the Water Vapour Permeability» that
implements the «wet cup» technology has been applied. The method has been employed to identify
the resistance of finishing layers of BAUMIT insulation system to the water vapour permeability.
BAUMIT has a thermal insulation layer made of mineral cotton. It has been identified that the overall
resistance of the finishing layer to the water vapour permeability, as determined in accordance with
the methodology developed by the authors, is twice as less efficient than the overall resistance
identified in accordance with prior methodologies. This difference in the characteristics of finishing
layers essentially raises the accuracy of projections of the moisture behaviour of all composite facade
insulation systems that have thin external plaster layers. |
topic |
thermal insulation systems coeffi cient of water vapour permeability resistance to water vapour permeability finishing layers |
url |
http://vestnikmgsu.ru/files/archive/issues/2012/11/ru/18.pdf |
work_keys_str_mv |
AT gagarinvladimirgennadevich methodologyofidentificationoftheoverallwatervapourpermeabilityresistanceofexternalfinishinglayersofcompositethermalinsulationfacadesystemsthathaveexternalplasterlayers AT pastushkovpavelpavlovich methodologyofidentificationoftheoverallwatervapourpermeabilityresistanceofexternalfinishinglayersofcompositethermalinsulationfacadesystemsthathaveexternalplasterlayers |
_version_ |
1725623279727673344 |