A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

Background: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. Methods: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45) – Airtraq laryngoscope was used f...

Full description

Bibliographic Details
Main Authors: Bikramjit Das, Rajiv Kumar Samal, Arup Ghosh, Ratul Kundu
Format: Article
Language:English
Published: Elsevier 2016-01-01
Series:Brazilian Journal of Anesthesiology
Online Access:http://www.sciencedirect.com/science/article/pii/S0104001414001766
id doaj-b35af09f83c3406fb0ad22420f4c1dab
record_format Article
spelling doaj-b35af09f83c3406fb0ad22420f4c1dab2020-11-24T23:51:14ZengElsevierBrazilian Journal of Anesthesiology0104-00142016-01-016611923A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgeryBikramjit Das0Rajiv Kumar Samal1Arup Ghosh2Ratul Kundu3Department of Anaesthesiology, Govt. Medical College and S.T.M. Hospital, Uttarakhand, India; Corresponding author.Department of Anaesthesiology, Institute of Post Graduate Medical Education Research, West Bengal, IndiaDepartment of Anaesthesiology, Institute of Post Graduate Medical Education Research, West Bengal, IndiaDepartment of Anaesthesiology, Institute of Post Graduate Medical Education Research, West Bengal, IndiaBackground: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. Methods: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45) – Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45) – conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. Results: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. Conclusion: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation. Resumo: Justificativa: Comparamos as alterações de pressão intraocular após laringoscopia e intubação com lâmina Macintosh convencional e laringoscópio óptico Airtraq. Métodos: Noventa pacientes adultos foram randomicamente designados para os grupos estudo ou controle. No grupo estudo (n = 45), o laringoscópio Airtraq foi usado para laringoscopia e no grupo controle (n = 45), o laringoscópio Macintosh convencional foi usado para laringoscopia. A pressão intraocular foi mensurada no pré-operatório com tonômetro Schiotz. A laringoscopia foi realizada de acordo com o protocolo de cada grupo. Pressão intraocular e parâmetros hemodinâmicos foram registrados logo antes da inserção do dispositivo e três vezes após a inserção do dispositivo, com intervalo de um minuto. Resultados: As características dos pacientes, os parâmetros hemodinâmicos basais e a PIO basal foram comparáveis nos dois grupos. Após a inserção do tubo endotraqueal com o laringoscópio Macintosh, houve um aumento estatisticamente significativo da frequência cardíaca e da pressão intraocular em comparação com o grupo Airtraq. Não houve alteração significativa da PAM. Oito pacientes do grupo Macintosh sofreram trauma de língua-lábio-dental durante a intubação, enquanto apenas dois pacientes sofreram trauma das vias aéreas superiores no grupo Airtraq. Conclusão: Concluímos que o laringoscópio Airtraq, em comparação com o laringoscópio Macintosh, resultou em elevações significativamente menores da PIO e em aumentos clinicamente menos acentuados da resposta hemodinâmica à laringoscopia e intubação. Keywords: Airtraq, Haemodynamic response, Intraocular pressure, Macintosh blade, Palavras-chave: Airtraq, Resposta hemodinâmica, Pressão intraocular, Lâmina Macintoshhttp://www.sciencedirect.com/science/article/pii/S0104001414001766
collection DOAJ
language English
format Article
sources DOAJ
author Bikramjit Das
Rajiv Kumar Samal
Arup Ghosh
Ratul Kundu
spellingShingle Bikramjit Das
Rajiv Kumar Samal
Arup Ghosh
Ratul Kundu
A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
Brazilian Journal of Anesthesiology
author_facet Bikramjit Das
Rajiv Kumar Samal
Arup Ghosh
Ratul Kundu
author_sort Bikramjit Das
title A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
title_short A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
title_full A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
title_fullStr A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
title_full_unstemmed A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
title_sort randomised comparative study of the effect of airtraq optical laryngoscope vs. macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
publisher Elsevier
series Brazilian Journal of Anesthesiology
issn 0104-0014
publishDate 2016-01-01
description Background: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. Methods: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45) – Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45) – conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. Results: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. Conclusion: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation. Resumo: Justificativa: Comparamos as alterações de pressão intraocular após laringoscopia e intubação com lâmina Macintosh convencional e laringoscópio óptico Airtraq. Métodos: Noventa pacientes adultos foram randomicamente designados para os grupos estudo ou controle. No grupo estudo (n = 45), o laringoscópio Airtraq foi usado para laringoscopia e no grupo controle (n = 45), o laringoscópio Macintosh convencional foi usado para laringoscopia. A pressão intraocular foi mensurada no pré-operatório com tonômetro Schiotz. A laringoscopia foi realizada de acordo com o protocolo de cada grupo. Pressão intraocular e parâmetros hemodinâmicos foram registrados logo antes da inserção do dispositivo e três vezes após a inserção do dispositivo, com intervalo de um minuto. Resultados: As características dos pacientes, os parâmetros hemodinâmicos basais e a PIO basal foram comparáveis nos dois grupos. Após a inserção do tubo endotraqueal com o laringoscópio Macintosh, houve um aumento estatisticamente significativo da frequência cardíaca e da pressão intraocular em comparação com o grupo Airtraq. Não houve alteração significativa da PAM. Oito pacientes do grupo Macintosh sofreram trauma de língua-lábio-dental durante a intubação, enquanto apenas dois pacientes sofreram trauma das vias aéreas superiores no grupo Airtraq. Conclusão: Concluímos que o laringoscópio Airtraq, em comparação com o laringoscópio Macintosh, resultou em elevações significativamente menores da PIO e em aumentos clinicamente menos acentuados da resposta hemodinâmica à laringoscopia e intubação. Keywords: Airtraq, Haemodynamic response, Intraocular pressure, Macintosh blade, Palavras-chave: Airtraq, Resposta hemodinâmica, Pressão intraocular, Lâmina Macintosh
url http://www.sciencedirect.com/science/article/pii/S0104001414001766
work_keys_str_mv AT bikramjitdas arandomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT rajivkumarsamal arandomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT arupghosh arandomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT ratulkundu arandomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT bikramjitdas randomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT rajivkumarsamal randomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT arupghosh randomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
AT ratulkundu randomisedcomparativestudyoftheeffectofairtraqopticallaryngoscopevsmacintoshlaryngoscopeonintraocularpressureinnonophthalmicsurgery
_version_ 1725476828127166464