A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample

This study presents a simple, low-cost, sensitive and environmentally friendly approach for the simultaneous electrochemical determination of lead and cadmium based on a commercial screen-printed gold electrode (SPGE) with Nafion and an in situ bismuth film. The developed sensor was coated with a Na...

Full description

Bibliographic Details
Main Authors: Ibtihaj Albalawi, Anna Hogan, Hanan Alatawi, Eric Moore
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:Sensing and Bio-Sensing Research
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214180421000593
id doaj-b6f0381b2f1e42c1b653a9d491fb8316
record_format Article
spelling doaj-b6f0381b2f1e42c1b653a9d491fb83162021-09-29T04:25:17ZengElsevierSensing and Bio-Sensing Research2214-18042021-12-0134100454A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sampleIbtihaj Albalawi0Anna Hogan1Hanan Alatawi2Eric Moore3Corresponding authors.; Department of Chemistry, University College Cork, IrelandDepartment of Chemistry, University College Cork, IrelandDepartment of Chemistry, University College Cork, IrelandCorresponding authors.; Department of Chemistry, University College Cork, IrelandThis study presents a simple, low-cost, sensitive and environmentally friendly approach for the simultaneous electrochemical determination of lead and cadmium based on a commercial screen-printed gold electrode (SPGE) with Nafion and an in situ bismuth film. The developed sensor was coated with a Nafion polymer to reduce the interference and enhance the stability and reproducibility of the gold working electrode and an in situ bismuth film to increase the sensitivity and achieve a low detection limit. Electrochemical properties were investigated using anodic stripping square voltammetry. The composite film was characterized using cyclic voltammetry, and scanning electron microscopy was carried out for the morphological characterization of the modified electrode. It was found that the prepared electrode has high sensitivity and good repeatability with a limit of detection below the Environmental Protection Agency limits (5 µg/L Cd and 10 µg/L Pb). The linear calibration curves for Pb(II) ranged from 20 ppb to 300 ppb, and for Cd(II), they ranged from 50 ppb to 300 ppb. The detection limits (S/N = 3) were estimated to be 3 ppb for Pb(II) and 4 ppb for Cd(II). This method was effectively applied in the application of river and tap water samples, and the results were compared with flame-atomic absorption spectroscopy analysis.http://www.sciencedirect.com/science/article/pii/S2214180421000593Anodic stripping voltammetryGold screen printed electrodeCadmium and lead detectionNafion-Bismuth
collection DOAJ
language English
format Article
sources DOAJ
author Ibtihaj Albalawi
Anna Hogan
Hanan Alatawi
Eric Moore
spellingShingle Ibtihaj Albalawi
Anna Hogan
Hanan Alatawi
Eric Moore
A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
Sensing and Bio-Sensing Research
Anodic stripping voltammetry
Gold screen printed electrode
Cadmium and lead detection
Nafion-Bismuth
author_facet Ibtihaj Albalawi
Anna Hogan
Hanan Alatawi
Eric Moore
author_sort Ibtihaj Albalawi
title A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
title_short A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
title_full A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
title_fullStr A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
title_full_unstemmed A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
title_sort sensitive electrochemical analysis for cadmium and lead based on nafion-bismuth film in a water sample
publisher Elsevier
series Sensing and Bio-Sensing Research
issn 2214-1804
publishDate 2021-12-01
description This study presents a simple, low-cost, sensitive and environmentally friendly approach for the simultaneous electrochemical determination of lead and cadmium based on a commercial screen-printed gold electrode (SPGE) with Nafion and an in situ bismuth film. The developed sensor was coated with a Nafion polymer to reduce the interference and enhance the stability and reproducibility of the gold working electrode and an in situ bismuth film to increase the sensitivity and achieve a low detection limit. Electrochemical properties were investigated using anodic stripping square voltammetry. The composite film was characterized using cyclic voltammetry, and scanning electron microscopy was carried out for the morphological characterization of the modified electrode. It was found that the prepared electrode has high sensitivity and good repeatability with a limit of detection below the Environmental Protection Agency limits (5 µg/L Cd and 10 µg/L Pb). The linear calibration curves for Pb(II) ranged from 20 ppb to 300 ppb, and for Cd(II), they ranged from 50 ppb to 300 ppb. The detection limits (S/N = 3) were estimated to be 3 ppb for Pb(II) and 4 ppb for Cd(II). This method was effectively applied in the application of river and tap water samples, and the results were compared with flame-atomic absorption spectroscopy analysis.
topic Anodic stripping voltammetry
Gold screen printed electrode
Cadmium and lead detection
Nafion-Bismuth
url http://www.sciencedirect.com/science/article/pii/S2214180421000593
work_keys_str_mv AT ibtihajalbalawi asensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT annahogan asensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT hananalatawi asensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT ericmoore asensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT ibtihajalbalawi sensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT annahogan sensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT hananalatawi sensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
AT ericmoore sensitiveelectrochemicalanalysisforcadmiumandleadbasedonnafionbismuthfilminawatersample
_version_ 1716864809750757376