Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation

Regarding the possibility of harmonic generation, personal computers (PCs) are very significant within the category of non-linear low power loads. In modern distribution systems, the number of PCs simultaneously connected to distribution grid constantly increases. This PC clustering can negativel...

Full description

Bibliographic Details
Main Authors: KATIC, V., RADULOVIC, V., DJUKANOVIC, S., MUJOVIC, S., RASOVIC, M.
Format: Article
Language:English
Published: Stefan cel Mare University of Suceava 2013-11-01
Series:Advances in Electrical and Computer Engineering
Subjects:
Online Access:http://dx.doi.org/10.4316/AECE.2013.04022
id doaj-c393fc5d42af4009897e82b7c6e50573
record_format Article
spelling doaj-c393fc5d42af4009897e82b7c6e505732020-11-24T21:03:13ZengStefan cel Mare University of SuceavaAdvances in Electrical and Computer Engineering1582-74451844-76002013-11-0113413313810.4316/AECE.2013.04022Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster OperationKATIC, V.RADULOVIC, V.DJUKANOVIC, S.MUJOVIC, S.RASOVIC, M.Regarding the possibility of harmonic generation, personal computers (PCs) are very significant within the category of non-linear low power loads. In modern distribution systems, the number of PCs simultaneously connected to distribution grid constantly increases. This PC clustering can negatively affect the quality of supply. The paper deals with mathematical modeling of the voltage total harmonic distortion (THDU) caused by operation of PC cluster. The proposed model is based on the power quality measurements carried out in a computer centre and computer simulations. It takes into account the THDU dependence on the PC cluster size and grid stiffness. Model parameters are derived in the least squares sense. The influences of cable cross-section and pre-existing THDU of the phase voltage are also discussed. The accuracy of the proposed model is confirmed by additional measurements performed in a commercial building.http://dx.doi.org/10.4316/AECE.2013.04022load modelingtotal harmonic distortionvoltage measurement
collection DOAJ
language English
format Article
sources DOAJ
author KATIC, V.
RADULOVIC, V.
DJUKANOVIC, S.
MUJOVIC, S.
RASOVIC, M.
spellingShingle KATIC, V.
RADULOVIC, V.
DJUKANOVIC, S.
MUJOVIC, S.
RASOVIC, M.
Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
Advances in Electrical and Computer Engineering
load modeling
total harmonic distortion
voltage measurement
author_facet KATIC, V.
RADULOVIC, V.
DJUKANOVIC, S.
MUJOVIC, S.
RASOVIC, M.
author_sort KATIC, V.
title Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
title_short Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
title_full Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
title_fullStr Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
title_full_unstemmed Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation
title_sort least squares modeling of voltage harmonic distortion due to pc cluster operation
publisher Stefan cel Mare University of Suceava
series Advances in Electrical and Computer Engineering
issn 1582-7445
1844-7600
publishDate 2013-11-01
description Regarding the possibility of harmonic generation, personal computers (PCs) are very significant within the category of non-linear low power loads. In modern distribution systems, the number of PCs simultaneously connected to distribution grid constantly increases. This PC clustering can negatively affect the quality of supply. The paper deals with mathematical modeling of the voltage total harmonic distortion (THDU) caused by operation of PC cluster. The proposed model is based on the power quality measurements carried out in a computer centre and computer simulations. It takes into account the THDU dependence on the PC cluster size and grid stiffness. Model parameters are derived in the least squares sense. The influences of cable cross-section and pre-existing THDU of the phase voltage are also discussed. The accuracy of the proposed model is confirmed by additional measurements performed in a commercial building.
topic load modeling
total harmonic distortion
voltage measurement
url http://dx.doi.org/10.4316/AECE.2013.04022
work_keys_str_mv AT katicv leastsquaresmodelingofvoltageharmonicdistortionduetopcclusteroperation
AT radulovicv leastsquaresmodelingofvoltageharmonicdistortionduetopcclusteroperation
AT djukanovics leastsquaresmodelingofvoltageharmonicdistortionduetopcclusteroperation
AT mujovics leastsquaresmodelingofvoltageharmonicdistortionduetopcclusteroperation
AT rasovicm leastsquaresmodelingofvoltageharmonicdistortionduetopcclusteroperation
_version_ 1716773785652166656