Validation and Optimization of Proximal Femurs Microstructure Analysis Using High Field and Ultra-High Field MRI

Trabecular bone could be assessed non-invasively using MRI. However, MRI does not yet provide resolutions lower than trabecular thickness and a comparative analysis between different MRI sequences at different field strengths and X-ray microtomography (μCT) is still missing. In this study, we compar...

Full description

Bibliographic Details
Main Authors: Enrico Soldati, Jerome Vicente, Daphne Guenoun, David Bendahan, Martine Pithioux
Format: Article
Language:English
Published: MDPI AG 2021-09-01
Series:Diagnostics
Subjects:
Online Access:https://www.mdpi.com/2075-4418/11/9/1603