A procedure for stable electrical measurements on a rock sample against high contact resistance as a prerequisite for electrical tomography

Abstract As a basis for the electrical tomography of laboratory-scale rock samples (~ 10 cm), we developed a procedure for stable, multi-point, electrical measurement on rock samples that is effective even at high contact and sample resistance. Electrodes were strongly attached to the surface of hig...

Full description

Bibliographic Details
Main Authors: Takeshi Suzuki, Ryokei Yoshimura, Ken’ichi Yamazaki, Naoto Oshiman
Format: Article
Language:English
Published: SpringerOpen 2021-06-01
Series:Earth, Planets and Space
Subjects:
Online Access:https://doi.org/10.1186/s40623-021-01446-9