Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction

Background: Currently, there is no uniform standard for selecting the left double lumen tubes (LDLT). Advantages, such as safety and convenience of the ultrasonic technology, and measurement accuracy, make it more widely applied in the clinical anesthesia, and computed tomography (CT) multi-planar r...

Full description

Bibliographic Details
Main Authors: Chengchao Zhang, Xinlei Qin, Wenyi Zhou, Shuaijie He, Ao Liu, Yu Zhang, Zhigang Dai, Jiangwen Yin
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-06-01
Series:Frontiers in Medicine
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fmed.2021.657612/full
id doaj-d767574757c84847a682871d8105eacb
record_format Article
spelling doaj-d767574757c84847a682871d8105eacb2021-06-16T06:33:25ZengFrontiers Media S.A.Frontiers in Medicine2296-858X2021-06-01810.3389/fmed.2021.657612657612Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar ReconstructionChengchao ZhangXinlei QinWenyi ZhouShuaijie HeAo LiuYu ZhangZhigang DaiJiangwen YinBackground: Currently, there is no uniform standard for selecting the left double lumen tubes (LDLT). Advantages, such as safety and convenience of the ultrasonic technology, and measurement accuracy, make it more widely applied in the clinical anesthesia, and computed tomography (CT) multi-planar reconstruction (MPR) technology will certainly provide a more accurate measurement. For better application for thoracic surgery choice LDLT, relieving the injury to patients, and reducing the complications, this study will compare the two approaches.Methods: The first part, 120 cases of patients were selected according to the height and gender; recording the patient's optimum LDLT and measurement the transverse diameter of the cricoid cartilage (TD-C) by ultrasound and CT MPR, and then obtained the TD-C range measurement by ultrasound and CT MPR corresponding to different types of LDLT. The second part, total of 102 patients were divided into the ultrasound group and the CT MPR group. In the ultrasound group, TD-C was measured by ultrasound, the corresponding size for intubation was selected based on the conclusions derived from the first part. In the CT MPR group, TD-C was measured by CT MPR, the corresponding size of LDLT based on the conclusions derived from the first part.Results: In the first part, 120 patients were no significant difference in the basic characteristics (P > 0.05). The accuracy of selecting the LDLT by conventional experience, namely height and gender was 58.3%. Ultrasonic measurement TD-C range was as follows: 32 Fr <15.88, 35 Fr: 15.88–16.80, 37 Fr: 16.75–17.81, and 39 Fr > 17.80. CT MPR measurement TD-C range was as follows: 32 Fr <15.74, 35 Fr: 15.74–16.65, 37 Fr: 16.56–17.68, and 39 Fr > 17.65. In the second part, there was no significant difference in the basic characteristics between the two groups (P > 0.05). The accuracy of intubation in the ultrasound group was 90.2% and the corresponding in the CT MPR group was 94.1% (P > 0.05).Conclusions: The accuracy of selecting the LDLT based on TD-C is significantly higher than conventional experience; it can significantly reduce the post-operative complications and there was no statistical significance in the accuracy of LDLT selected for TD-C measurement by ultrasound vs. CT, and both of them could be safely used for the evaluation before intubation under anesthesia in thoracic surgery.https://www.frontiersin.org/articles/10.3389/fmed.2021.657612/fullultrasoundCT multi-planar reconstructioncricoid cartilage transverse diameterleft double lumen tubeone lung ventilation
collection DOAJ
language English
format Article
sources DOAJ
author Chengchao Zhang
Xinlei Qin
Wenyi Zhou
Shuaijie He
Ao Liu
Yu Zhang
Zhigang Dai
Jiangwen Yin
spellingShingle Chengchao Zhang
Xinlei Qin
Wenyi Zhou
Shuaijie He
Ao Liu
Yu Zhang
Zhigang Dai
Jiangwen Yin
Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
Frontiers in Medicine
ultrasound
CT multi-planar reconstruction
cricoid cartilage transverse diameter
left double lumen tube
one lung ventilation
author_facet Chengchao Zhang
Xinlei Qin
Wenyi Zhou
Shuaijie He
Ao Liu
Yu Zhang
Zhigang Dai
Jiangwen Yin
author_sort Chengchao Zhang
title Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
title_short Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
title_full Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
title_fullStr Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
title_full_unstemmed Prediction of Left Double-Lumen Tube Size by Measurement of Cricoid Cartilage Transverse Diameter by Ultrasound and CT Multi-Planar Reconstruction
title_sort prediction of left double-lumen tube size by measurement of cricoid cartilage transverse diameter by ultrasound and ct multi-planar reconstruction
publisher Frontiers Media S.A.
series Frontiers in Medicine
issn 2296-858X
publishDate 2021-06-01
description Background: Currently, there is no uniform standard for selecting the left double lumen tubes (LDLT). Advantages, such as safety and convenience of the ultrasonic technology, and measurement accuracy, make it more widely applied in the clinical anesthesia, and computed tomography (CT) multi-planar reconstruction (MPR) technology will certainly provide a more accurate measurement. For better application for thoracic surgery choice LDLT, relieving the injury to patients, and reducing the complications, this study will compare the two approaches.Methods: The first part, 120 cases of patients were selected according to the height and gender; recording the patient's optimum LDLT and measurement the transverse diameter of the cricoid cartilage (TD-C) by ultrasound and CT MPR, and then obtained the TD-C range measurement by ultrasound and CT MPR corresponding to different types of LDLT. The second part, total of 102 patients were divided into the ultrasound group and the CT MPR group. In the ultrasound group, TD-C was measured by ultrasound, the corresponding size for intubation was selected based on the conclusions derived from the first part. In the CT MPR group, TD-C was measured by CT MPR, the corresponding size of LDLT based on the conclusions derived from the first part.Results: In the first part, 120 patients were no significant difference in the basic characteristics (P > 0.05). The accuracy of selecting the LDLT by conventional experience, namely height and gender was 58.3%. Ultrasonic measurement TD-C range was as follows: 32 Fr <15.88, 35 Fr: 15.88–16.80, 37 Fr: 16.75–17.81, and 39 Fr > 17.80. CT MPR measurement TD-C range was as follows: 32 Fr <15.74, 35 Fr: 15.74–16.65, 37 Fr: 16.56–17.68, and 39 Fr > 17.65. In the second part, there was no significant difference in the basic characteristics between the two groups (P > 0.05). The accuracy of intubation in the ultrasound group was 90.2% and the corresponding in the CT MPR group was 94.1% (P > 0.05).Conclusions: The accuracy of selecting the LDLT based on TD-C is significantly higher than conventional experience; it can significantly reduce the post-operative complications and there was no statistical significance in the accuracy of LDLT selected for TD-C measurement by ultrasound vs. CT, and both of them could be safely used for the evaluation before intubation under anesthesia in thoracic surgery.
topic ultrasound
CT multi-planar reconstruction
cricoid cartilage transverse diameter
left double lumen tube
one lung ventilation
url https://www.frontiersin.org/articles/10.3389/fmed.2021.657612/full
work_keys_str_mv AT chengchaozhang predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT xinleiqin predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT wenyizhou predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT shuaijiehe predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT aoliu predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT yuzhang predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT zhigangdai predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
AT jiangwenyin predictionofleftdoublelumentubesizebymeasurementofcricoidcartilagetransversediameterbyultrasoundandctmultiplanarreconstruction
_version_ 1721375542767255552