Adaptive impedance matching method based on magnetic resonance wireless energy transmission

In order to solve the problem of low efficiency and transmission distance of multi-to-1(multi transmit(TX) coils to one receive(RX) coil)coupled magnetic resonance(CMR) wireless power transmission system, this paper presents 2-to-1(two TX Coils to one RX coil) of the CMR wireless energy transmission...

Full description

Bibliographic Details
Main Authors: Xiong Wei, Liu Xiaojing
Format: Article
Language:zho
Published: National Computer System Engineering Research Institute of China 2018-07-01
Series:Dianzi Jishu Yingyong
Subjects:
Online Access:http://www.chinaaet.com/article/3000086752
id doaj-d79b2adda95c433eb8356f1586a07e3d
record_format Article
spelling doaj-d79b2adda95c433eb8356f1586a07e3d2020-11-24T21:34:38ZzhoNational Computer System Engineering Research Institute of ChinaDianzi Jishu Yingyong0258-79982018-07-0144711211610.16157/j.issn.0258-7998.1743273000086752Adaptive impedance matching method based on magnetic resonance wireless energy transmissionXiong Wei0Liu Xiaojing1Hubei Collaborative Innovation Center for High-efficiency Utilization of Solar Energy, Hubei University of Technology,Wuhan 430068,ChinaSchool of Electrical and Electronic Engineering,Hubei University of Technology,Wuhan 430068,ChinaIn order to solve the problem of low efficiency and transmission distance of multi-to-1(multi transmit(TX) coils to one receive(RX) coil)coupled magnetic resonance(CMR) wireless power transmission system, this paper presents 2-to-1(two TX Coils to one RX coil) of the CMR wireless energy transmission system of the adaptive impedance matching method. The principle of this method is that when the load impedance is matched to the equivalent internal impedance of the power source, power can be transmitted to the load without reflection, but it is usually not matched. Therefore, the LC impedance matching network(IMN) is used to make the source resistance and the load side impedance equal. As the RX coil changes in the spatial position of the transmitter will cause the input impedance changes, this paper sets different LC impedance matching network for different RX coil position, so that it can achieve the purpose of adaptive impedance matching. Finally, after the test, with the RX coil in the spatial position of the change, the impedance matching network can quickly achieve automatic matching, energy transfer efficiency is up to 87%, and the mobile phone charging distance increases to 10 cm or more.http://www.chinaaet.com/article/3000086752coupled magnetic resonanceadaptive impedance matching2-to-1 CMR system
collection DOAJ
language zho
format Article
sources DOAJ
author Xiong Wei
Liu Xiaojing
spellingShingle Xiong Wei
Liu Xiaojing
Adaptive impedance matching method based on magnetic resonance wireless energy transmission
Dianzi Jishu Yingyong
coupled magnetic resonance
adaptive impedance matching
2-to-1 CMR system
author_facet Xiong Wei
Liu Xiaojing
author_sort Xiong Wei
title Adaptive impedance matching method based on magnetic resonance wireless energy transmission
title_short Adaptive impedance matching method based on magnetic resonance wireless energy transmission
title_full Adaptive impedance matching method based on magnetic resonance wireless energy transmission
title_fullStr Adaptive impedance matching method based on magnetic resonance wireless energy transmission
title_full_unstemmed Adaptive impedance matching method based on magnetic resonance wireless energy transmission
title_sort adaptive impedance matching method based on magnetic resonance wireless energy transmission
publisher National Computer System Engineering Research Institute of China
series Dianzi Jishu Yingyong
issn 0258-7998
publishDate 2018-07-01
description In order to solve the problem of low efficiency and transmission distance of multi-to-1(multi transmit(TX) coils to one receive(RX) coil)coupled magnetic resonance(CMR) wireless power transmission system, this paper presents 2-to-1(two TX Coils to one RX coil) of the CMR wireless energy transmission system of the adaptive impedance matching method. The principle of this method is that when the load impedance is matched to the equivalent internal impedance of the power source, power can be transmitted to the load without reflection, but it is usually not matched. Therefore, the LC impedance matching network(IMN) is used to make the source resistance and the load side impedance equal. As the RX coil changes in the spatial position of the transmitter will cause the input impedance changes, this paper sets different LC impedance matching network for different RX coil position, so that it can achieve the purpose of adaptive impedance matching. Finally, after the test, with the RX coil in the spatial position of the change, the impedance matching network can quickly achieve automatic matching, energy transfer efficiency is up to 87%, and the mobile phone charging distance increases to 10 cm or more.
topic coupled magnetic resonance
adaptive impedance matching
2-to-1 CMR system
url http://www.chinaaet.com/article/3000086752
work_keys_str_mv AT xiongwei adaptiveimpedancematchingmethodbasedonmagneticresonancewirelessenergytransmission
AT liuxiaojing adaptiveimpedancematchingmethodbasedonmagneticresonancewirelessenergytransmission
_version_ 1725948455599210496