Equivalent Magnetic Circuit Reluctance Optimization for Rotor Loss Reduction in Permanent Magnet Synchronous Motor for UPS-FESS
Due to poor heat dissipation of rotor, especially in flywheel energy storage system (FESS) for uninterruptible power supply (UPS), there is a higher risk of irreversible demagnetization by rotor temperature rising. Irreversible demagnetization of permanent magnets by rotor loss always is a critical...