Microfluidic devices for studying early response of cytokine signaling

Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2008. === Includes bibliographical references (p. 111-125). === This thesis presents the design, fabrication, and characterization of a microfluidic device integrated with cell culture, cell stimulation, and prote...

Full description

Bibliographic Details
Main Author: Ye, Linlin, Ph. D. Massachusetts Institute of Technology
Other Authors: Klavs F. Jensen.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2008
Subjects:
Online Access:http://hdl.handle.net/1721.1/43218
id ndltd-MIT-oai-dspace.mit.edu-1721.1-43218
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-432182019-05-02T16:31:01Z Microfluidic devices for studying early response of cytokine signaling Ye, Linlin, Ph. D. Massachusetts Institute of Technology Klavs F. Jensen. Massachusetts Institute of Technology. Dept. of Chemical Engineering. Massachusetts Institute of Technology. Dept. of Chemical Engineering. Chemical Engineering. Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2008. Includes bibliographical references (p. 111-125). This thesis presents the design, fabrication, and characterization of a microfluidic device integrated with cell culture, cell stimulation, and protein analysis as a single device towards an efficient and productive cell-based assay development. In particular, this thesis demonstrates the feasibility of culturing human cancer cells in microliter-volume reactors in batch and fed-batch operations, stimulating the cell under well-controlled and reproducible conditions at early stages, and detecting the protein signals with an immunocytochemical (In-Cell Western) assay. These microfluidic devices take advantage of microfabrication techniques to create an environment suitable for cell culture, biomechanical and biochemical stimulation of cells, and protein detection and analysis. The microfluidic approach greatly reduces the amounts of samples and reagents necessary for these procedures and the required process time compared with their macroscopic counterparts. Moreover, the technique integrates unit operations, such as cell culture, stimulation, and protein analysis, in a single microchip. The microfluidic technique presented in this thesis correlates the space in the microchannels with the biological process time (cell stimulation time). Thus, a single experiment in one microfluidic device is capable of generating a complete temporal cell response curve, which otherwise would have required multiple experiments and manual assays by standard microwells and pipetting techniques. The developed method also provides high time-resolution and reproducible data for studies of cell signaling events, especially at early stages. These cell signaling events are difficult to be investigated by conventional techniques. The thesis reports the development not only of a cell population analysis method, but also of a single-cell detection and analysis technique to explore cell-to-cell variations. (cont.) In this study, a new microscope stage holder was designed and machined, and an auto cell counting algorithm was developed for the single-cell analysis. This single-cell method provided data on cell-to-cell variations and showed that the average cell signaling profiles were consistent with those by population-based analysis. The integration of the single-cell imaging and microfluidic method enabled measurements shows promise as a technique for exploring the cell signaling with single-cell resolutions. by Linlin Ye. Ph.D. 2008-11-07T19:17:09Z 2008-11-07T19:17:09Z 2008 2008 Thesis http://hdl.handle.net/1721.1/43218 259202328 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 125 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Chemical Engineering.
spellingShingle Chemical Engineering.
Ye, Linlin, Ph. D. Massachusetts Institute of Technology
Microfluidic devices for studying early response of cytokine signaling
description Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2008. === Includes bibliographical references (p. 111-125). === This thesis presents the design, fabrication, and characterization of a microfluidic device integrated with cell culture, cell stimulation, and protein analysis as a single device towards an efficient and productive cell-based assay development. In particular, this thesis demonstrates the feasibility of culturing human cancer cells in microliter-volume reactors in batch and fed-batch operations, stimulating the cell under well-controlled and reproducible conditions at early stages, and detecting the protein signals with an immunocytochemical (In-Cell Western) assay. These microfluidic devices take advantage of microfabrication techniques to create an environment suitable for cell culture, biomechanical and biochemical stimulation of cells, and protein detection and analysis. The microfluidic approach greatly reduces the amounts of samples and reagents necessary for these procedures and the required process time compared with their macroscopic counterparts. Moreover, the technique integrates unit operations, such as cell culture, stimulation, and protein analysis, in a single microchip. The microfluidic technique presented in this thesis correlates the space in the microchannels with the biological process time (cell stimulation time). Thus, a single experiment in one microfluidic device is capable of generating a complete temporal cell response curve, which otherwise would have required multiple experiments and manual assays by standard microwells and pipetting techniques. The developed method also provides high time-resolution and reproducible data for studies of cell signaling events, especially at early stages. These cell signaling events are difficult to be investigated by conventional techniques. The thesis reports the development not only of a cell population analysis method, but also of a single-cell detection and analysis technique to explore cell-to-cell variations. === (cont.) In this study, a new microscope stage holder was designed and machined, and an auto cell counting algorithm was developed for the single-cell analysis. This single-cell method provided data on cell-to-cell variations and showed that the average cell signaling profiles were consistent with those by population-based analysis. The integration of the single-cell imaging and microfluidic method enabled measurements shows promise as a technique for exploring the cell signaling with single-cell resolutions. === by Linlin Ye. === Ph.D.
author2 Klavs F. Jensen.
author_facet Klavs F. Jensen.
Ye, Linlin, Ph. D. Massachusetts Institute of Technology
author Ye, Linlin, Ph. D. Massachusetts Institute of Technology
author_sort Ye, Linlin, Ph. D. Massachusetts Institute of Technology
title Microfluidic devices for studying early response of cytokine signaling
title_short Microfluidic devices for studying early response of cytokine signaling
title_full Microfluidic devices for studying early response of cytokine signaling
title_fullStr Microfluidic devices for studying early response of cytokine signaling
title_full_unstemmed Microfluidic devices for studying early response of cytokine signaling
title_sort microfluidic devices for studying early response of cytokine signaling
publisher Massachusetts Institute of Technology
publishDate 2008
url http://hdl.handle.net/1721.1/43218
work_keys_str_mv AT yelinlinphdmassachusettsinstituteoftechnology microfluidicdevicesforstudyingearlyresponseofcytokinesignaling
_version_ 1719041903991717888