The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer

碩士 === 國立臺灣大學 === 機械工程學研究所 === 99 === The study intends to develop a cloth dryer with a portion of re-circulate the exhaust air directly back into the drum. The main purpose of the study is recovering of heat and reusing of the exhaust air to decrease the waste of the energy. The re-circulate of t...

Full description

Bibliographic Details
Main Authors: Wei-Loon Hew, 邱偉倫
Other Authors: Sih-Li Chen
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/50275599982739581802
id ndltd-TW-099NTU05489034
record_format oai_dc
spelling ndltd-TW-099NTU054890342015-10-16T04:02:49Z http://ndltd.ncl.edu.tw/handle/50275599982739581802 The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer 烘衣機排氣熱回收再利用之性能研究 Wei-Loon Hew 邱偉倫 碩士 國立臺灣大學 機械工程學研究所 99 The study intends to develop a cloth dryer with a portion of re-circulate the exhaust air directly back into the drum. The main purpose of the study is recovering of heat and reusing of the exhaust air to decrease the waste of the energy. The re-circulate of the exhaust air will be inducted to a mixing and dehumidifier chamber and mix with the air inside before the mixing air induct into the drum. Meanwhile the exhaust air will cause the temperature of the mixing air to be risen. As a result of the risen temperature of the intake air, the power consumption of the heater will be lowered and the total power consumption is also lowered as well. The study discusses different designs of drying process of household clothes tumbler dryer. A parametric study was conducted to assess the effects of different re-circulation factor of the exhaust air on energy efficiency, drying efficiency and specific moisture extraction rate (SMER). The studies compare the energy efficiency, drying efficiency and specific moisture extraction rate (SMER) of the baseline with the different re-circulation factor. According to the experimental measurement results, an optimal efficiency is found at a re-circulation factor of about 80%. As an addition, the energy savings are in the range of 25~30% and has smallest SMER as well as the highest drying efficiency. Besides that, including a dehumidify device inside the mixing chamber will increase the performance of the dryer more than only re-circulating the exhaust air. Sih-Li Chen 陳希立 2011 學位論文 ; thesis 83 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 機械工程學研究所 === 99 === The study intends to develop a cloth dryer with a portion of re-circulate the exhaust air directly back into the drum. The main purpose of the study is recovering of heat and reusing of the exhaust air to decrease the waste of the energy. The re-circulate of the exhaust air will be inducted to a mixing and dehumidifier chamber and mix with the air inside before the mixing air induct into the drum. Meanwhile the exhaust air will cause the temperature of the mixing air to be risen. As a result of the risen temperature of the intake air, the power consumption of the heater will be lowered and the total power consumption is also lowered as well. The study discusses different designs of drying process of household clothes tumbler dryer. A parametric study was conducted to assess the effects of different re-circulation factor of the exhaust air on energy efficiency, drying efficiency and specific moisture extraction rate (SMER). The studies compare the energy efficiency, drying efficiency and specific moisture extraction rate (SMER) of the baseline with the different re-circulation factor. According to the experimental measurement results, an optimal efficiency is found at a re-circulation factor of about 80%. As an addition, the energy savings are in the range of 25~30% and has smallest SMER as well as the highest drying efficiency. Besides that, including a dehumidify device inside the mixing chamber will increase the performance of the dryer more than only re-circulating the exhaust air.
author2 Sih-Li Chen
author_facet Sih-Li Chen
Wei-Loon Hew
邱偉倫
author Wei-Loon Hew
邱偉倫
spellingShingle Wei-Loon Hew
邱偉倫
The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
author_sort Wei-Loon Hew
title The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
title_short The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
title_full The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
title_fullStr The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
title_full_unstemmed The Performance Investigation of Air Recirculation for Heat Recovery in a Clothes Dryer
title_sort performance investigation of air recirculation for heat recovery in a clothes dryer
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/50275599982739581802
work_keys_str_mv AT weiloonhew theperformanceinvestigationofairrecirculationforheatrecoveryinaclothesdryer
AT qiūwěilún theperformanceinvestigationofairrecirculationforheatrecoveryinaclothesdryer
AT weiloonhew hōngyījīpáiqìrèhuíshōuzàilìyòngzhīxìngnéngyánjiū
AT qiūwěilún hōngyījīpáiqìrèhuíshōuzàilìyòngzhīxìngnéngyánjiū
AT weiloonhew performanceinvestigationofairrecirculationforheatrecoveryinaclothesdryer
AT qiūwěilún performanceinvestigationofairrecirculationforheatrecoveryinaclothesdryer
_version_ 1718091503831613440