碩士 === 國立中央大學 === 能源工程研究所 === 103 === Abstract In present study, the test section has used a transparent plate heat exchanger to visualize flow distribution. Using water-air flow to simulate refrigerant’s condition at the entrance of evaporator. The range of experiments are from Reynolds number 50 t...