Multi-Variable Control of Variable-Frequency Air Conditioner

碩士 === 國立臺灣大學 === 機械工程學研究所 === 104 === The main purpose of the present research is to develop a variable-frequency air conditioner system. By modifying the frequency of the compressor and the opening of the electronic expansion valve, we can precisely control room temperature and superheat temperatu...

Full description

Bibliographic Details
Main Authors: Wei-Jen Chen, 陳威仁
Other Authors: 黃秉鈞
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/50615414725387915463
id ndltd-TW-104NTU05489001
record_format oai_dc
spelling ndltd-TW-104NTU054890012017-05-20T04:30:06Z http://ndltd.ncl.edu.tw/handle/50615414725387915463 Multi-Variable Control of Variable-Frequency Air Conditioner 變頻空調多變量控制技術研究 Wei-Jen Chen 陳威仁 碩士 國立臺灣大學 機械工程學研究所 104 The main purpose of the present research is to develop a variable-frequency air conditioner system. By modifying the frequency of the compressor and the opening of the electronic expansion valve, we can precisely control room temperature and superheat temperature. The multi-variable control system is simplified to two individual single variable control systems, while the interaction is treated as the disturbance process of the control system. A prototype of variable-frequency air conditioner system was built and tested. The experiment results show that the room temperature error is less than 0.1℃ and the superheat temperature error is less than 1℃. The performance of the designed variable-frequency air conditioner system is shown satisfactory. 黃秉鈞 2016 學位論文 ; thesis 84 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 機械工程學研究所 === 104 === The main purpose of the present research is to develop a variable-frequency air conditioner system. By modifying the frequency of the compressor and the opening of the electronic expansion valve, we can precisely control room temperature and superheat temperature. The multi-variable control system is simplified to two individual single variable control systems, while the interaction is treated as the disturbance process of the control system. A prototype of variable-frequency air conditioner system was built and tested. The experiment results show that the room temperature error is less than 0.1℃ and the superheat temperature error is less than 1℃. The performance of the designed variable-frequency air conditioner system is shown satisfactory.
author2 黃秉鈞
author_facet 黃秉鈞
Wei-Jen Chen
陳威仁
author Wei-Jen Chen
陳威仁
spellingShingle Wei-Jen Chen
陳威仁
Multi-Variable Control of Variable-Frequency Air Conditioner
author_sort Wei-Jen Chen
title Multi-Variable Control of Variable-Frequency Air Conditioner
title_short Multi-Variable Control of Variable-Frequency Air Conditioner
title_full Multi-Variable Control of Variable-Frequency Air Conditioner
title_fullStr Multi-Variable Control of Variable-Frequency Air Conditioner
title_full_unstemmed Multi-Variable Control of Variable-Frequency Air Conditioner
title_sort multi-variable control of variable-frequency air conditioner
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/50615414725387915463
work_keys_str_mv AT weijenchen multivariablecontrolofvariablefrequencyairconditioner
AT chénwēirén multivariablecontrolofvariablefrequencyairconditioner
AT weijenchen biànpínkōngdiàoduōbiànliàngkòngzhìjìshùyánjiū
AT chénwēirén biànpínkōngdiàoduōbiànliàngkòngzhìjìshùyánjiū
_version_ 1718449947713470464