Comparative performance analysis of bridgeless boost and bridgeless buck converter for UPS application

In this paper, a comparative performance analysis of bridgeless boost and bridgeless buck converter for Uninterruptable Power Supply (UPS) is presented. The performance of UPS application in terms of their efficiency is compared between the conventional diode bridge converter and both bridgeless con...

Full description

Bibliographic Details
Main Authors: Baharom, R. (Author), Muhammad, K.S (Author), Munim, W.N.W.A (Author), Siti Zaliha, M.N (Author)
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science, 2020
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 01994nam a2200217Ia 4500
001 10.11591-ijpeds.v11.i2.pp801-809
008 220121s2020 CNT 000 0 und d
020 |a 20888694 (ISSN) 
245 1 0 |a Comparative performance analysis of bridgeless boost and bridgeless buck converter for UPS application 
260 0 |b Institute of Advanced Engineering and Science,  |c 2020 
650 0 4 |a Bridgeless Boost Converter 
650 0 4 |a Bridgeless Buck Converter 
650 0 4 |a UPS Application 
856 |z View Fulltext in Publisher  |u https://doi.org/10.11591/ijpeds.v11.i2.pp801-809 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85081614687&doi=10.11591%2fijpeds.v11.i2.pp801-809&partnerID=40&md5=7d1d219e4c2ff7eb4e69d41dddd59200 
520 3 |a In this paper, a comparative performance analysis of bridgeless boost and bridgeless buck converter for Uninterruptable Power Supply (UPS) is presented. The performance of UPS application in terms of their efficiency is compared between the conventional diode bridge converter and both bridgeless converters. The input supply power quality is also been analysed by applying open and closed loop control techniques to the converter. The results show that the efficiency and the input supply quality of the bridgeless converters are significantly improved. UPS using bridgeless boost converter has better performance in all aspect compared to bridgeless buck converter. Aligned with that, the closed loop controller for the converter has also improved the efficiency and PF more than the open loop controller in performing the UPS system. All the analytical work was performed using PSIM software. © 2020, Institute of Advanced Engineering and Science. All rights reserved. 
700 1 0 |a Baharom, R.  |e author 
700 1 0 |a Muhammad, K.S.  |e author 
700 1 0 |a Munim, W.N.W.A.  |e author 
700 1 0 |a Siti Zaliha, M.N.  |e author 
773 |t International Journal of Power Electronics and Drive Systems  |x 20888694 (ISSN)  |g 11 2, 801-809