Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population

Background Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experien...

詳細記述

書誌詳細
出版年:Archives of Plastic Surgery
主要な著者: Yoon Jae Lee, SeongAe Kim, Jisung Lee, Joong Geel Chung, Young Joon Jun
フォーマット: 論文
言語:英語
出版事項: Thieme Medical Publishers, Inc. 2020-03-01
主題:
オンライン・アクセス:http://www.thieme-connect.de/DOI/DOI?10.5999/aps.2019.01102
_version_ 1851939404223873024
author Yoon Jae Lee
SeongAe Kim
Jisung Lee
Joong Geel Chung
Young Joon Jun
author_facet Yoon Jae Lee
SeongAe Kim
Jisung Lee
Joong Geel Chung
Young Joon Jun
author_sort Yoon Jae Lee
collection DOAJ
container_title Archives of Plastic Surgery
description Background Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. Methods A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. Results From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. Conclusions The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding.
format Article
id doaj-art-06e126afaafa4bc2bbd4947e85324d2d
institution Directory of Open Access Journals
issn 2234-6163
2234-6171
language English
publishDate 2020-03-01
publisher Thieme Medical Publishers, Inc.
record_format Article
spelling doaj-art-06e126afaafa4bc2bbd4947e85324d2d2025-08-19T21:51:00ZengThieme Medical Publishers, Inc.Archives of Plastic Surgery2234-61632234-61712020-03-01470217117710.5999/aps.2019.011023721Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian populationYoon Jae Lee0SeongAe Kim1Jisung Lee2Joong Geel Chung3Young Joon Jun4Department of Plastic and Reconstructive Surgery, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, KoreaDepartment of Plastic and Reconstructive Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, KoreaiWELL Plastic Surgery Clinic, Seoul, KoreaJoong Geel Chung Clinic of Plastic Surgery, Seoul, KoreaDepartment of Plastic and Reconstructive Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, KoreaBackground Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. Methods A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. Results From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. Conclusions The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding.http://www.thieme-connect.de/DOI/DOI?10.5999/aps.2019.01102eyelidsblepharoplastyeyebrow
spellingShingle Yoon Jae Lee
SeongAe Kim
Jisung Lee
Joong Geel Chung
Young Joon Jun
Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
eyelids
blepharoplasty
eyebrow
title Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_full Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_fullStr Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_full_unstemmed Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_short Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_sort parallel excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an asian population
topic eyelids
blepharoplasty
eyebrow
url http://www.thieme-connect.de/DOI/DOI?10.5999/aps.2019.01102
work_keys_str_mv AT yoonjaelee parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT seongaekim parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT jisunglee parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT joonggeelchung parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT youngjoonjun parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation