The Empirical Assessment of Vibration in HVAC Systems
Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods: In the first step of the study, the vibration accelerometer was p...
| 出版年: | علوم بهداشتی ایران |
|---|---|
| 主要な著者: | , , , |
| フォーマット: | 論文 |
| 言語: | 英語 |
| 出版事項: |
Mazandaran University of Medical Sciences
2021-12-01
|
| 主題: | |
| オンライン・アクセス: | http://jhs.mazums.ac.ir/article-1-781-en.html |
| _version_ | 1850318056163639296 |
|---|---|
| author | Farhad Forouharmajd Shiva Soury Mehran Mokhtari Zahra Mohammadii |
| author_facet | Farhad Forouharmajd Shiva Soury Mehran Mokhtari Zahra Mohammadii |
| author_sort | Farhad Forouharmajd |
| collection | DOAJ |
| container_title | علوم بهداشتی ایران |
| description | Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important.
Materials and Methods: In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration assessment of the building was conducted in the other steps to compare with guidelines. In the next step, the isolation method was used to control vibration. By placing the isolator on the duct wall, the accelerometer was located on the body of the duct wall and the value of vibration was measured in a millimeter per second. All stages of the experiment were performed in the Faculty of Health of Isfahan University of Medical Sciences in 2018.
Results: The maximum vibration velocity reduction in the building was related to the frequency of 68 Hz, which reached 33 mm/s after isolation. In addition, the fan vibration at 485 Hz was equal to 2.1 m /s, which decreased to 2 mm /s after isolation.
Conclusions: Comparison of vibration after fan isolation with standard showed that this method has been effective in reducing the fan vibration resulting in the vibration to reach below the standard. |
| format | Article |
| id | doaj-art-20f29dda4a73444fa9be2af8fcbbfb86 |
| institution | Directory of Open Access Journals |
| issn | 2322-553X 2322-4797 |
| language | English |
| publishDate | 2021-12-01 |
| publisher | Mazandaran University of Medical Sciences |
| record_format | Article |
| spelling | doaj-art-20f29dda4a73444fa9be2af8fcbbfb862025-08-19T23:23:44ZengMazandaran University of Medical Sciencesعلوم بهداشتی ایران2322-553X2322-47972021-12-01941219The Empirical Assessment of Vibration in HVAC SystemsFarhad Forouharmajd0Shiva Soury1Mehran Mokhtari2Zahra Mohammadii3 Department of Occupational Health Engineering, School of Public Health, Isfahan University of Medical Sciences, Isfahan, Iran Department of Occupational Health Engineering. School of Health, Ilam University of Medical Sciences, Ilam, Iran Department of aerospace engineering, Amirkabir University of Technology, Tehran, Iran Department of Occupational Health and Safety, School of Public Health and safety, Shahid Beheshti University of Medical Science, Tehran, Iran Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods: In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration assessment of the building was conducted in the other steps to compare with guidelines. In the next step, the isolation method was used to control vibration. By placing the isolator on the duct wall, the accelerometer was located on the body of the duct wall and the value of vibration was measured in a millimeter per second. All stages of the experiment were performed in the Faculty of Health of Isfahan University of Medical Sciences in 2018. Results: The maximum vibration velocity reduction in the building was related to the frequency of 68 Hz, which reached 33 mm/s after isolation. In addition, the fan vibration at 485 Hz was equal to 2.1 m /s, which decreased to 2 mm /s after isolation. Conclusions: Comparison of vibration after fan isolation with standard showed that this method has been effective in reducing the fan vibration resulting in the vibration to reach below the standard.http://jhs.mazums.ac.ir/article-1-781-en.htmlhuman vibrationbuildinghvac equipment |
| spellingShingle | Farhad Forouharmajd Shiva Soury Mehran Mokhtari Zahra Mohammadii The Empirical Assessment of Vibration in HVAC Systems human vibration building hvac equipment |
| title | The Empirical Assessment of Vibration in HVAC Systems |
| title_full | The Empirical Assessment of Vibration in HVAC Systems |
| title_fullStr | The Empirical Assessment of Vibration in HVAC Systems |
| title_full_unstemmed | The Empirical Assessment of Vibration in HVAC Systems |
| title_short | The Empirical Assessment of Vibration in HVAC Systems |
| title_sort | empirical assessment of vibration in hvac systems |
| topic | human vibration building hvac equipment |
| url | http://jhs.mazums.ac.ir/article-1-781-en.html |
| work_keys_str_mv | AT farhadforouharmajd theempiricalassessmentofvibrationinhvacsystems AT shivasoury theempiricalassessmentofvibrationinhvacsystems AT mehranmokhtari theempiricalassessmentofvibrationinhvacsystems AT zahramohammadii theempiricalassessmentofvibrationinhvacsystems AT farhadforouharmajd empiricalassessmentofvibrationinhvacsystems AT shivasoury empiricalassessmentofvibrationinhvacsystems AT mehranmokhtari empiricalassessmentofvibrationinhvacsystems AT zahramohammadii empiricalassessmentofvibrationinhvacsystems |