Impact of Omicron Variant Infection on Assessment of Spike-Specific Immune Responses Using the EUROIMMUN Quan-T-Cell SARS-CoV-2 Assay and Roche Elecsys Anti-SARS-CoV-2-S

The currently prevailing variants of SARS-CoV-2 are subvariants of the Omicron variant. The aim of this study was to analyze the effect of mutations in the Spike protein of Omicron on the results Quan-T-Cell SARS-CoV-2 assays and Roche Elecsys anti-SARS-CoV-2 anti-S1. Omicron infected subjects ((<...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Diagnostics
المؤلفون الرئيسيون: Mohamed I. M. Ahmed, Michael Plank, Noemi Castelletti, Paulina Diepers, Tabea M. Eser, Raquel Rubio-Acero, Ivan Noreña, Christina Reinkemeyer, Dorinja Zapf, Michael Hoelscher, Christian Janke, Andreas Wieser, Christof Geldmacher, on behalf of the KoCo19/ORCHESTRA Study Group
التنسيق: مقال
اللغة:الإنجليزية
منشور في: MDPI AG 2023-03-01
الموضوعات:
الوصول للمادة أونلاين:https://www.mdpi.com/2075-4418/13/6/1024
الوصف
الملخص:The currently prevailing variants of SARS-CoV-2 are subvariants of the Omicron variant. The aim of this study was to analyze the effect of mutations in the Spike protein of Omicron on the results Quan-T-Cell SARS-CoV-2 assays and Roche Elecsys anti-SARS-CoV-2 anti-S1. Omicron infected subjects ((<i>n</i> = 37), vaccinated (<i>n</i> = 20) and unvaccinated (<i>n</i> = 17)) were recruited approximately 3 weeks after a positive PCR test. The Quan-T-Cell SARS-CoV-2 assays (EUROIMMUN) using Wuhan and the Omicron adapted antigen assay and a serological test (Roche Elecsys anti-SARS-CoV-2 anti-S1) were performed. Using the original Wuhan SARS-CoV-2 IGRA TUBE, in 19 of 21 tested Omicron infected subjects, a positive IFNy response was detected, while 2 non-vaccinated but infected subjects did not respond. The Omicron adapted antigen tube resulted in comparable results. In contrast, the serological assay detected a factor 100-fold lower median Spike-specific RBD antibody concentration in non-vaccinated Omicron infected patients (<i>n</i> = 12) compared to patients from the pre Omicron era (<i>n</i> = 12) at matched time points, and eight individuals remained below the detection threshold for positivity. For vaccinated subjects, the Roche assay detected antibodies in all subjects and showed a 400 times higher median specific antibody concentration compared to non-vaccinated infected subjects in the pre-Omicron era. Our results suggest that Omicron antigen adapted IGRA stimulator tubes did not improve detection of SARS-CoV-2-specific T-cell responses in the Quant-T-Cell-SARS-CoV-2 assay. In non-vaccinated Omicron infected individuals, the Wuhan based Elecsys anti-SARS-CoV-2 anti-S1 serological assay results in many negative results at 3 weeks after diagnosis.
تدمد:2075-4418