Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses

Clayton Blehm,1 Brad Hall2 1Gainesville Eye Associates, Gainesville, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Clayton Blehm, Gainesville Eye Associates, 2061 Beverly Road, Gainesville, GA, 30501, USA, Tel +1 770-532-4444, Email claytonblehm@gmail.comPurpose: To determine the refractive pr...

Full description

Bibliographic Details
Published in:Clinical Ophthalmology
Main Authors: Blehm C, Hall B
Format: Article
Language:English
Published: Dove Medical Press 2023-11-01
Subjects:
Online Access:https://www.dovepress.com/refractive-predictability-of-a-swept-source-optical-coherence-tomograp-peer-reviewed-fulltext-article-OPTH
_version_ 1850329669334728704
author Blehm C
Hall B
author_facet Blehm C
Hall B
author_sort Blehm C
collection DOAJ
container_title Clinical Ophthalmology
description Clayton Blehm,1 Brad Hall2 1Gainesville Eye Associates, Gainesville, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Clayton Blehm, Gainesville Eye Associates, 2061 Beverly Road, Gainesville, GA, 30501, USA, Tel +1 770-532-4444, Email claytonblehm@gmail.comPurpose: To determine the refractive predictability of Argos (Movu, a Santec company) measurements and the Barrett Universal II formula in long and short eyes implanted with an extended depth of focus (EDOF) intraocular lens (IOL).Methods: This retrospective, non-interventional study included 86 eyes (55 long and 31 short) of 55 patients. Preoperative biometry was performed using the Argos. Preoperative IOL power formulas were the preprogrammed Barrett Universal II (BUII). Data were collected for refractive outcomes, postoperative prediction error (directional and absolute), and monocular corrected distance visual acuity (CDVA, Snellen).Results: The mean absolute prediction error for BUII was 0.27 ± 0.26 D overall, 0.24 ± 0.20 D in long eyes, and 0.33 ± 0.33 D in short eyes. Overall, the percentage of eyes with ≤ 0.5 D prediction error was 84% for BUII. In long eyes, the percentage of eyes with ≤ 0.5 D prediction error was 90% for BUII. In short eyes, the percentage of eyes with ≤ 0.5 D prediction error was 74% for BUII. The percentage of eyes with ≤ 0.5 D of MRSE was 89% for long eyes and 94% for short eyes. Visual acuities were excellent in both long and short eyes, with > 90% of eyes 20/25 or better in each group.Conclusion: The prediction error of Argos using BUII was low in long and short eyes at one month after EDOF IOL implantation.Plain Language Summary: An intraocular lens (IOL) is an artificial lens that can be implanted in the eye to replace a natural lens that has become opaque. The power of the IOL must be carefully chosen for clear vision after implantation. Cataract surgeons use devices called biometers to measure the eye and calculate the most appropriate IOL power to implant. A novel biometer is available that may offer good accuracy, for predicting the IOL power, in eyes that are longer or shorter than average. The purpose of this study was to determine the refractive predictability of this biometer in long and short eyes implanted with an extended depth of focus (EDOF) IOL. The results of this study suggest that the refractive predictability was excellent in long and short eyes at one month after EDOF IOL implantation, resulting in great vision postoperatively.Keywords: Argos, biometry, SS-OCT
format Article
id doaj-art-2b9e2bcf3ebf4fcd904b62b049940dfb
institution Directory of Open Access Journals
issn 1177-5483
language English
publishDate 2023-11-01
publisher Dove Medical Press
record_format Article
spelling doaj-art-2b9e2bcf3ebf4fcd904b62b049940dfb2025-08-19T23:18:46ZengDove Medical PressClinical Ophthalmology1177-54832023-11-01Volume 173525353088360Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular LensesBlehm CHall BClayton Blehm,1 Brad Hall2 1Gainesville Eye Associates, Gainesville, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Clayton Blehm, Gainesville Eye Associates, 2061 Beverly Road, Gainesville, GA, 30501, USA, Tel +1 770-532-4444, Email claytonblehm@gmail.comPurpose: To determine the refractive predictability of Argos (Movu, a Santec company) measurements and the Barrett Universal II formula in long and short eyes implanted with an extended depth of focus (EDOF) intraocular lens (IOL).Methods: This retrospective, non-interventional study included 86 eyes (55 long and 31 short) of 55 patients. Preoperative biometry was performed using the Argos. Preoperative IOL power formulas were the preprogrammed Barrett Universal II (BUII). Data were collected for refractive outcomes, postoperative prediction error (directional and absolute), and monocular corrected distance visual acuity (CDVA, Snellen).Results: The mean absolute prediction error for BUII was 0.27 ± 0.26 D overall, 0.24 ± 0.20 D in long eyes, and 0.33 ± 0.33 D in short eyes. Overall, the percentage of eyes with ≤ 0.5 D prediction error was 84% for BUII. In long eyes, the percentage of eyes with ≤ 0.5 D prediction error was 90% for BUII. In short eyes, the percentage of eyes with ≤ 0.5 D prediction error was 74% for BUII. The percentage of eyes with ≤ 0.5 D of MRSE was 89% for long eyes and 94% for short eyes. Visual acuities were excellent in both long and short eyes, with > 90% of eyes 20/25 or better in each group.Conclusion: The prediction error of Argos using BUII was low in long and short eyes at one month after EDOF IOL implantation.Plain Language Summary: An intraocular lens (IOL) is an artificial lens that can be implanted in the eye to replace a natural lens that has become opaque. The power of the IOL must be carefully chosen for clear vision after implantation. Cataract surgeons use devices called biometers to measure the eye and calculate the most appropriate IOL power to implant. A novel biometer is available that may offer good accuracy, for predicting the IOL power, in eyes that are longer or shorter than average. The purpose of this study was to determine the refractive predictability of this biometer in long and short eyes implanted with an extended depth of focus (EDOF) IOL. The results of this study suggest that the refractive predictability was excellent in long and short eyes at one month after EDOF IOL implantation, resulting in great vision postoperatively.Keywords: Argos, biometry, SS-OCThttps://www.dovepress.com/refractive-predictability-of-a-swept-source-optical-coherence-tomograp-peer-reviewed-fulltext-article-OPTHargosbiometryss-oct
spellingShingle Blehm C
Hall B
Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
argos
biometry
ss-oct
title Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
title_full Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
title_fullStr Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
title_full_unstemmed Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
title_short Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
title_sort refractive predictability of a swept source optical coherence tomography biometer in long and short eyes implanted with extended depth of focus intraocular lenses
topic argos
biometry
ss-oct
url https://www.dovepress.com/refractive-predictability-of-a-swept-source-optical-coherence-tomograp-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT blehmc refractivepredictabilityofasweptsourceopticalcoherencetomographybiometerinlongandshorteyesimplantedwithextendeddepthoffocusintraocularlenses
AT hallb refractivepredictabilityofasweptsourceopticalcoherencetomographybiometerinlongandshorteyesimplantedwithextendeddepthoffocusintraocularlenses