Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT
Based on the need for real-time sag monitoring of Overhead Power Lines (OPL) for electricity transmission, this article presents the implementation of a hardware and software system for online monitoring of OPL cables. The mathematical model based on differential equations and the methods of algorit...
| الحاوية / القاعدة: | Sensors |
|---|---|
| المؤلفون الرئيسيون: | , , , |
| التنسيق: | مقال |
| اللغة: | الإنجليزية |
| منشور في: |
MDPI AG
2024-07-01
|
| الموضوعات: | |
| الوصول للمادة أونلاين: | https://www.mdpi.com/1424-8220/24/13/4283 |
| _version_ | 1850390387202457600 |
|---|---|
| author | Claudiu-Ionel Nicola Marcel Nicola Dumitru Sacerdoțianu Ion Pătru |
| author_facet | Claudiu-Ionel Nicola Marcel Nicola Dumitru Sacerdoțianu Ion Pătru |
| author_sort | Claudiu-Ionel Nicola |
| collection | DOAJ |
| container_title | Sensors |
| description | Based on the need for real-time sag monitoring of Overhead Power Lines (OPL) for electricity transmission, this article presents the implementation of a hardware and software system for online monitoring of OPL cables. The mathematical model based on differential equations and the methods of algorithmic calculation of OPL cable sag are presented. Considering that, based on the mathematical model presented, the calculation of cable sag can be done in different ways depending on the sensors used, and the presented application uses a variety of sensors. Therefore, a direct calculation is made using one of the different methods. Subsequently, the verification relations are highlighted directly, and in return, the calculation by the alternative method, which uses another group of sensors, generates both a verification of the calculation and the functionality of the sensors, thus obtaining a defect observer of the sensors. The hardware architecture of the OPL cable online monitoring application is presented, together with the main characteristics of the sensors and communication equipment used. The configurations required to transmit data using the ModBUS and ZigBee protocols are also presented. The main software modules of the OPL cable condition monitoring application are described, which ensure the monitoring of the main parameters of the power line and the visualisation of the results both on the electricity provider’s intranet using a web server and MySQL database, and on the Internet using an Internet of Things (IoT) server. This categorisation of the data visualisation mode is done in such a way as to ensure a high level of cyber security. Also, the global accuracy of the entire OPL cable sag calculus system is estimated at 0.1%. Starting from the mathematical model of the OPL cable sag calculation, it goes through the stages of creating such a monitoring system, from the numerical simulations carried out using Matlab to the real-time implementation of this monitoring application using Laboratory Virtual Instrument Engineering Workbench (LabVIEW). |
| format | Article |
| id | doaj-art-2ef6462cb55b4bbbbb247dea28ed8dc4 |
| institution | Directory of Open Access Journals |
| issn | 1424-8220 |
| language | English |
| publishDate | 2024-07-01 |
| publisher | MDPI AG |
| record_format | Article |
| spelling | doaj-art-2ef6462cb55b4bbbbb247dea28ed8dc42025-08-19T22:54:05ZengMDPI AGSensors1424-82202024-07-012413428310.3390/s24134283Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoTClaudiu-Ionel Nicola0Marcel Nicola1Dumitru Sacerdoțianu2Ion Pătru3Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, RomaniaResearch and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, RomaniaResearch and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, RomaniaResearch and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, RomaniaBased on the need for real-time sag monitoring of Overhead Power Lines (OPL) for electricity transmission, this article presents the implementation of a hardware and software system for online monitoring of OPL cables. The mathematical model based on differential equations and the methods of algorithmic calculation of OPL cable sag are presented. Considering that, based on the mathematical model presented, the calculation of cable sag can be done in different ways depending on the sensors used, and the presented application uses a variety of sensors. Therefore, a direct calculation is made using one of the different methods. Subsequently, the verification relations are highlighted directly, and in return, the calculation by the alternative method, which uses another group of sensors, generates both a verification of the calculation and the functionality of the sensors, thus obtaining a defect observer of the sensors. The hardware architecture of the OPL cable online monitoring application is presented, together with the main characteristics of the sensors and communication equipment used. The configurations required to transmit data using the ModBUS and ZigBee protocols are also presented. The main software modules of the OPL cable condition monitoring application are described, which ensure the monitoring of the main parameters of the power line and the visualisation of the results both on the electricity provider’s intranet using a web server and MySQL database, and on the Internet using an Internet of Things (IoT) server. This categorisation of the data visualisation mode is done in such a way as to ensure a high level of cyber security. Also, the global accuracy of the entire OPL cable sag calculus system is estimated at 0.1%. Starting from the mathematical model of the OPL cable sag calculation, it goes through the stages of creating such a monitoring system, from the numerical simulations carried out using Matlab to the real-time implementation of this monitoring application using Laboratory Virtual Instrument Engineering Workbench (LabVIEW).https://www.mdpi.com/1424-8220/24/13/4283cable sagZigBeeModBUSweb serverIoT |
| spellingShingle | Claudiu-Ionel Nicola Marcel Nicola Dumitru Sacerdoțianu Ion Pătru Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT cable sag ZigBee ModBUS web server IoT |
| title | Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT |
| title_full | Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT |
| title_fullStr | Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT |
| title_full_unstemmed | Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT |
| title_short | Real-Time Monitoring of Cable Sag and Overhead Power Line Parameters Based on a Distributed Sensor Network and Implementation in a Web Server and IoT |
| title_sort | real time monitoring of cable sag and overhead power line parameters based on a distributed sensor network and implementation in a web server and iot |
| topic | cable sag ZigBee ModBUS web server IoT |
| url | https://www.mdpi.com/1424-8220/24/13/4283 |
| work_keys_str_mv | AT claudiuionelnicola realtimemonitoringofcablesagandoverheadpowerlineparametersbasedonadistributedsensornetworkandimplementationinawebserverandiot AT marcelnicola realtimemonitoringofcablesagandoverheadpowerlineparametersbasedonadistributedsensornetworkandimplementationinawebserverandiot AT dumitrusacerdotianu realtimemonitoringofcablesagandoverheadpowerlineparametersbasedonadistributedsensornetworkandimplementationinawebserverandiot AT ionpatru realtimemonitoringofcablesagandoverheadpowerlineparametersbasedonadistributedsensornetworkandimplementationinawebserverandiot |