Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019

To evaluate the APF of an air conditioner according to GB 21455—2019, the performance parameters of low-temperature intermediate cooling conditions can be measured or converted, resulting in two different APF values using these two different methods in the same air conditioner. Considering the diffe...

全面介绍

书目详细资料
发表在:Zhileng xuebao
Main Authors: Chen Xuancheng, Zhuang Dawei, Ding Guoliang, Yu Yuefeng, Cheng Jianhong, Wu Guoming
格式: 文件
语言:中文
出版: Journal of Refrigeration Magazines Agency Co., Ltd. 2023-01-01
主题:
在线阅读:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.04.127
_version_ 1849700154448281600
author Chen Xuancheng
Zhuang Dawei
Ding Guoliang
Yu Yuefeng
Cheng Jianhong
Wu Guoming
author_facet Chen Xuancheng
Zhuang Dawei
Ding Guoliang
Yu Yuefeng
Cheng Jianhong
Wu Guoming
author_sort Chen Xuancheng
collection DOAJ
container_title Zhileng xuebao
description To evaluate the APF of an air conditioner according to GB 21455—2019, the performance parameters of low-temperature intermediate cooling conditions can be measured or converted, resulting in two different APF values using these two different methods in the same air conditioner. Considering the difference in results obtained by the different methods in the national standard, it is necessary to analyze the rationality of the difference and propose an improvement plan. Based on the definition formula of APF, this study presents the reason for the difference in the APF value determined by the test method and the conversion method at the low-temperature intermediate refrigeration condition. The test method given in the national standard causes a variation in energy efficiency under rated intermediate cooling conditions, contrary to the variation in the calculated APF value, which is not reasonable. One possible way to solve the problem of non-uniqueness of APF values is to change the method of obtaining the performance parameters of the low-temperature intermediate refrigeration operating condition stipulated in the national standard from "obtained by testing or conversion according to the rated intermediate refrigeration operating condition" to "obtained only by conversion according to the rated intermediate refrigeration operating condition."
format Article
id doaj-art-393c8dcb52d84f8984e45baaac736bd5
institution Directory of Open Access Journals
issn 0253-4339
language zho
publishDate 2023-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
spelling doaj-art-393c8dcb52d84f8984e45baaac736bd52025-08-20T02:03:00ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392023-01-014466502187Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019Chen XuanchengZhuang DaweiDing GuoliangYu YuefengCheng JianhongWu GuomingTo evaluate the APF of an air conditioner according to GB 21455—2019, the performance parameters of low-temperature intermediate cooling conditions can be measured or converted, resulting in two different APF values using these two different methods in the same air conditioner. Considering the difference in results obtained by the different methods in the national standard, it is necessary to analyze the rationality of the difference and propose an improvement plan. Based on the definition formula of APF, this study presents the reason for the difference in the APF value determined by the test method and the conversion method at the low-temperature intermediate refrigeration condition. The test method given in the national standard causes a variation in energy efficiency under rated intermediate cooling conditions, contrary to the variation in the calculated APF value, which is not reasonable. One possible way to solve the problem of non-uniqueness of APF values is to change the method of obtaining the performance parameters of the low-temperature intermediate refrigeration operating condition stipulated in the national standard from "obtained by testing or conversion according to the rated intermediate refrigeration operating condition" to "obtained only by conversion according to the rated intermediate refrigeration operating condition."http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.04.127APFair conditionerlow-temperature intermediate refrigeration conditionenergy efficiency standard for air conditioners
spellingShingle Chen Xuancheng
Zhuang Dawei
Ding Guoliang
Yu Yuefeng
Cheng Jianhong
Wu Guoming
Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
APF
air conditioner
low-temperature intermediate refrigeration condition
energy efficiency standard for air conditioners
title Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
title_full Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
title_fullStr Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
title_full_unstemmed Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
title_short Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
title_sort analysis on apf calculation problem caused by the optional method to obtaining performance parameters of low temperature intermediate refrigeration condition in gb 21455 2019
topic APF
air conditioner
low-temperature intermediate refrigeration condition
energy efficiency standard for air conditioners
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.04.127
work_keys_str_mv AT chenxuancheng analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019
AT zhuangdawei analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019
AT dingguoliang analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019
AT yuyuefeng analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019
AT chengjianhong analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019
AT wuguoming analysisonapfcalculationproblemcausedbytheoptionalmethodtoobtainingperformanceparametersoflowtemperatureintermediaterefrigerationconditioningb214552019