Coupling Calculation of 3D Flow Field & Temperature Field for Permanent Magnet Synchronous Motor

With the decreasing in volume and increasing of power density, the accurate estimation of permanent magnet synchronous motor in terms of temperature rise has become a problem in the design process. In order to solve this problem, a permanent magnet synchronous motor was taken as a research object, t...

Full description

Bibliographic Details
Published in:Kongzhi Yu Xinxi Jishu
Main Authors: DING Jie, ZHANG Ping, LI Yifeng, YANG Jinxia
Format: Article
Language:Chinese
Published: Editorial Office of Control and Information Technology 2014-01-01
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2014.06.010
Description
Summary:With the decreasing in volume and increasing of power density, the accurate estimation of permanent magnet synchronous motor in terms of temperature rise has become a problem in the design process. In order to solve this problem, a permanent magnet synchronous motor was taken as a research object, three-dimensional flow and heat transfer coupling simulation model of the motor was solved by using multiple reference frame model and finite volume method based on the basic assumptions and solution conditions. The internal fluid flow characteristics, the whole temperature field, the stator and rotor temperature field and the convection heat transfer coefficient distribution were analyzed. The research methods and results can provide guidance for the thermal design of permanent magnet synchronous motor.