Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi

Interleukin-6 (IL-6) is a biomarker of inflammation, the advanced stage of COVID-19, and several cancers, including ovarian cancer. Two biosensors for the determination of IL-6 in blood plasma by array SPRi have been developed. One of these biosensors consists of the mouse monoclonal anti-IL-6 antib...

Full description

Bibliographic Details
Published in:Biosensors
Main Authors: Beata Szymanska, Zenon Lukaszewski, Lukasz Oldak, Beata Zelazowska-Rutkowska, Kinga Hermanowicz-Szamatowicz, Ewa Gorodkiewicz
Format: Article
Language:English
Published: MDPI AG 2022-06-01
Subjects:
Online Access:https://www.mdpi.com/2079-6374/12/6/412
_version_ 1850034066879938560
author Beata Szymanska
Zenon Lukaszewski
Lukasz Oldak
Beata Zelazowska-Rutkowska
Kinga Hermanowicz-Szamatowicz
Ewa Gorodkiewicz
author_facet Beata Szymanska
Zenon Lukaszewski
Lukasz Oldak
Beata Zelazowska-Rutkowska
Kinga Hermanowicz-Szamatowicz
Ewa Gorodkiewicz
author_sort Beata Szymanska
collection DOAJ
container_title Biosensors
description Interleukin-6 (IL-6) is a biomarker of inflammation, the advanced stage of COVID-19, and several cancers, including ovarian cancer. Two biosensors for the determination of IL-6 in blood plasma by array SPRi have been developed. One of these biosensors consists of the mouse monoclonal anti-IL-6 antibody as the receptor immobilized via the cysteamine linker. The second contains galiellalactone as the receptor, being an inhibitor specific for IL-6, immobilized via octadecanethiol (ODM) as the linker. Both biosensors are specific for IL-6. The biosensor with the antibody as the receptor gives a linear analytical response between 3 (LOQ) and 20 pg mL<sup>−1</sup> and has a precision between 8% and 9.8% and recovery between 97% and 107%, depending on the IL-6 concentration. The biosensor with galiellalactone as the receptor gives a linear analytical response between 1.1 (LOQ) and 20 pg mL<sup>−1</sup>, and has a precision between 3.5% and 9.3% and recovery between 101% and 105%, depending on IL-6 concentration. Both biosensors were validated. Changes in IL-6 concentration in blood plasma before and after resection of ovarian tumor and endometrial cyst, as determined by the two developed biosensors, are given as an example of a real clinical application.
format Article
id doaj-art-5417536d4dcf40748d42790d8ba9b429
institution Directory of Open Access Journals
issn 2079-6374
language English
publishDate 2022-06-01
publisher MDPI AG
record_format Article
spelling doaj-art-5417536d4dcf40748d42790d8ba9b4292025-08-20T00:34:54ZengMDPI AGBiosensors2079-63742022-06-0112641210.3390/bios12060412Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRiBeata Szymanska0Zenon Lukaszewski1Lukasz Oldak2Beata Zelazowska-Rutkowska3Kinga Hermanowicz-Szamatowicz4Ewa Gorodkiewicz5Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, PolandFaculty of Chemical Technology, Poznan University of Technology, pl. Sklodowskiej-Curie 5, 60-965 Poznan, PolandBioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, PolandDepartment of Pediatric Laboratory Diagnostics, Medical University of Bialystok, Waszyngtona 17, 15-274 Bialystok, PolandDepartment of Clinical Oncology, Comprehensive Cancer Center, Ogrodowa 12, 15-027 Bialystok, PolandBioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, PolandInterleukin-6 (IL-6) is a biomarker of inflammation, the advanced stage of COVID-19, and several cancers, including ovarian cancer. Two biosensors for the determination of IL-6 in blood plasma by array SPRi have been developed. One of these biosensors consists of the mouse monoclonal anti-IL-6 antibody as the receptor immobilized via the cysteamine linker. The second contains galiellalactone as the receptor, being an inhibitor specific for IL-6, immobilized via octadecanethiol (ODM) as the linker. Both biosensors are specific for IL-6. The biosensor with the antibody as the receptor gives a linear analytical response between 3 (LOQ) and 20 pg mL<sup>−1</sup> and has a precision between 8% and 9.8% and recovery between 97% and 107%, depending on the IL-6 concentration. The biosensor with galiellalactone as the receptor gives a linear analytical response between 1.1 (LOQ) and 20 pg mL<sup>−1</sup>, and has a precision between 3.5% and 9.3% and recovery between 101% and 105%, depending on IL-6 concentration. Both biosensors were validated. Changes in IL-6 concentration in blood plasma before and after resection of ovarian tumor and endometrial cyst, as determined by the two developed biosensors, are given as an example of a real clinical application.https://www.mdpi.com/2079-6374/12/6/412interleukin-6array SPRicancer biomarkersovarian cancerblood plasma
spellingShingle Beata Szymanska
Zenon Lukaszewski
Lukasz Oldak
Beata Zelazowska-Rutkowska
Kinga Hermanowicz-Szamatowicz
Ewa Gorodkiewicz
Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
interleukin-6
array SPRi
cancer biomarkers
ovarian cancer
blood plasma
title Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
title_full Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
title_fullStr Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
title_full_unstemmed Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
title_short Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi
title_sort two biosensors for the determination of interleukin 6 in blood plasma by array spri
topic interleukin-6
array SPRi
cancer biomarkers
ovarian cancer
blood plasma
url https://www.mdpi.com/2079-6374/12/6/412
work_keys_str_mv AT beataszymanska twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri
AT zenonlukaszewski twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri
AT lukaszoldak twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri
AT beatazelazowskarutkowska twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri
AT kingahermanowiczszamatowicz twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri
AT ewagorodkiewicz twobiosensorsforthedeterminationofinterleukin6inbloodplasmabyarrayspri