Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner

The purpose of our study was to assess the role of a 64-slice multidetector CT (MDCT) scanner in the characterization of different solid renal masses, using a simplified approach to correct the postenhancement attenuation values. The study included 96 consecutive adults (58 men, 38 women) with renal...

Full description

Bibliographic Details
Published in:The Scientific World Journal
Main Authors: Saleh S. El-Esawy, Mohamed E. Abou El-Ghar, Ghada M. Gaballa, Saly A. Zahra
Format: Article
Language:English
Published: Wiley 2009-01-01
Online Access:http://dx.doi.org/10.1100/tsw.2009.65
_version_ 1849439395824795648
author Saleh S. El-Esawy
Mohamed E. Abou El-Ghar
Ghada M. Gaballa
Saly A. Zahra
author_facet Saleh S. El-Esawy
Mohamed E. Abou El-Ghar
Ghada M. Gaballa
Saly A. Zahra
author_sort Saleh S. El-Esawy
collection DOAJ
container_title The Scientific World Journal
description The purpose of our study was to assess the role of a 64-slice multidetector CT (MDCT) scanner in the characterization of different solid renal masses, using a simplified approach to correct the postenhancement attenuation values. The study included 96 consecutive adults (58 men, 38 women) with renal masses; 93 with unilateral and three with bilateral masses. All of our patients underwent multiphasic CT study including pre- and postcontrast corticomedullary (CM) and nephrographic phases. We analyzed the images and corrected the postcontrast attenuation values at the CM phase. The postbiopsy or -surgical data were used as reference standard. There were 53 masses at the right kidney, 40 at the left kidney, and three bilateral. The final diagnosis of the 96 solid parenchymal masses were 28 clear-type renal cell carcinoma (RCC), 22 papillary-type RCC, 21 chromophobe-type RCC, six XP 11.2 chromosomal translocation–type RCC, 15 angiomyolipoma (AML), and seven oncocytoma. All the AML had fat, with attenuation values less than -40 HU at the nonenhanced scan. There is no difference in the precontrast attenuation values for the different types other than AML. At the postcontrast CM phase after the correction of the attenuation values, the clear cell type could be separated easily, with attenuation values >20 with specificity, sensitivity, and overall accuracy of 92, 84, and 93%, respectively. The 64-slice MDCT scanner with application of enhancement values correction allows diagnosis of clear cell carcinoma. Also, AML could be identified easily with fat inside at the precontrast scan.
format Article
id doaj-art-69b50fdfab3c40fcbb6d6e080e2fad25
institution Directory of Open Access Journals
issn 1537-744X
language English
publishDate 2009-01-01
publisher Wiley
record_format Article
spelling doaj-art-69b50fdfab3c40fcbb6d6e080e2fad252025-08-20T03:34:08ZengWileyThe Scientific World Journal1537-744X2009-01-01944144810.1100/tsw.2009.65Characterization of Solid Renal Masses using 64-Slice Multidetector CT ScannerSaleh S. El-Esawy0Mohamed E. Abou El-Ghar1Ghada M. Gaballa2Saly A. Zahra3Mansoura University, EgyptMansoura University, EgyptMansoura University, EgyptMansoura University, EgyptThe purpose of our study was to assess the role of a 64-slice multidetector CT (MDCT) scanner in the characterization of different solid renal masses, using a simplified approach to correct the postenhancement attenuation values. The study included 96 consecutive adults (58 men, 38 women) with renal masses; 93 with unilateral and three with bilateral masses. All of our patients underwent multiphasic CT study including pre- and postcontrast corticomedullary (CM) and nephrographic phases. We analyzed the images and corrected the postcontrast attenuation values at the CM phase. The postbiopsy or -surgical data were used as reference standard. There were 53 masses at the right kidney, 40 at the left kidney, and three bilateral. The final diagnosis of the 96 solid parenchymal masses were 28 clear-type renal cell carcinoma (RCC), 22 papillary-type RCC, 21 chromophobe-type RCC, six XP 11.2 chromosomal translocation–type RCC, 15 angiomyolipoma (AML), and seven oncocytoma. All the AML had fat, with attenuation values less than -40 HU at the nonenhanced scan. There is no difference in the precontrast attenuation values for the different types other than AML. At the postcontrast CM phase after the correction of the attenuation values, the clear cell type could be separated easily, with attenuation values >20 with specificity, sensitivity, and overall accuracy of 92, 84, and 93%, respectively. The 64-slice MDCT scanner with application of enhancement values correction allows diagnosis of clear cell carcinoma. Also, AML could be identified easily with fat inside at the precontrast scan.http://dx.doi.org/10.1100/tsw.2009.65
spellingShingle Saleh S. El-Esawy
Mohamed E. Abou El-Ghar
Ghada M. Gaballa
Saly A. Zahra
Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title_full Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title_fullStr Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title_full_unstemmed Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title_short Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
title_sort characterization of solid renal masses using 64 slice multidetector ct scanner
url http://dx.doi.org/10.1100/tsw.2009.65
work_keys_str_mv AT salehselesawy characterizationofsolidrenalmassesusing64slicemultidetectorctscanner
AT mohamedeabouelghar characterizationofsolidrenalmassesusing64slicemultidetectorctscanner
AT ghadamgaballa characterizationofsolidrenalmassesusing64slicemultidetectorctscanner
AT salyazahra characterizationofsolidrenalmassesusing64slicemultidetectorctscanner