Protocol for large scale whole blood immune monitoring by mass cytometry and Cyto Quality Pipeline

Summary: Mass cytometry (MC) is a powerful large-scale immune monitoring technology. To maximize MC data quality, we present a protocol for whole blood analysis together with an R package, Cyto Quality Pipeline (CytoQP), which minimizes the experimental artifacts and batch effects to ensure data rep...

Full description

Bibliographic Details
Published in:STAR Protocols
Main Authors: Paulina Rybakowska, Sofie Van Gassen, Jordi Martorell Marugán, Katrien Quintelier, Yvan Saeys, Marta E. Alarcón-Riquelme, Concepción Marañón
Format: Article
Language:English
Published: Elsevier 2022-12-01
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666166722005779
Description
Summary:Summary: Mass cytometry (MC) is a powerful large-scale immune monitoring technology. To maximize MC data quality, we present a protocol for whole blood analysis together with an R package, Cyto Quality Pipeline (CytoQP), which minimizes the experimental artifacts and batch effects to ensure data reproducibility. We describe the steps to stimulate, fix, and freeze blood samples before acquisition to make them suitable for retrospective studies. We then detail the use of barcoding and reference samples to facilitate multicenter and multi-batch experiments.For complete details on the use and execution of this protocol, please refer to Rybakowska et al. (2021a) and (2021b). : Publisher’s note: Undertaking any experimental protocol requires adherence to local institutional guidelines for laboratory safety and ethics.
ISSN:2666-1667