A Simplified Correlation Index for Fast Real-Time Pulse Shape Recognition

A simplified correlation index is proposed to be used in real-time pulse shape recognition systems. This index is similar to the classic Pearson’s correlation coefficient, but it can be efficiently implemented in FPGA devices with far fewer logic resources and excellent performance. Numerical simula...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Sensors
المؤلفون الرئيسيون: Andres Cicuttin, Iván René Morales, Maria Liz Crespo, Sergio Carrato, Luis Guillermo García, Romina Soledad Molina, Bruno Valinoti, Jerome Folla Kamdem
التنسيق: مقال
اللغة:الإنجليزية
منشور في: MDPI AG 2022-10-01
الموضوعات:
الوصول للمادة أونلاين:https://www.mdpi.com/1424-8220/22/20/7697
الوصف
الملخص:A simplified correlation index is proposed to be used in real-time pulse shape recognition systems. This index is similar to the classic Pearson’s correlation coefficient, but it can be efficiently implemented in FPGA devices with far fewer logic resources and excellent performance. Numerical simulations with synthetic data and comparisons with the Pearson’s correlation show the suitability of the proposed index in applications such as the discrimination and counting of pulses with a predefined shape. Superior performance is evident in signal-to-noise ratio scenarios close to unity. FPGA implementation of Person’s method and the proposed correlation index have been successfully tested and the main results are summarized.
تدمد:1424-8220