Seismic Response of GFRP-RC Interior Beam-to-Column Joints under Cyclic Static Loads

A total of nine specimens were constructed and tested under cyclic loads to investigate the differences in seismic behavior between glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) joints and RC beam-to-column joints. The experimental parameters included stirrup ratios, axial pressure...

Full description

Bibliographic Details
Published in:Buildings
Main Authors: Rui Guo, Dan Yang, Bin Jia, Deyun Tang
Format: Article
Language:English
Published: MDPI AG 2022-11-01
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/11/1987
Description
Summary:A total of nine specimens were constructed and tested under cyclic loads to investigate the differences in seismic behavior between glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) joints and RC beam-to-column joints. The experimental parameters included stirrup ratios, axial pressure ratios and concrete strength of the beam-to-column joints. The cyclic loading test results showed that the GFRP-RC beam-to-column joints can withstand significantly high lateral deformations without exhibiting brittle failure. Moreover, the RC beam-to-column joint exhibited significantly higher energy dissipation and residual displacement than the GFRP-RC beam-to-column joint by 50% and 60%, respectively. Finally, a shear capacity calculation method for the core zone of this kind of joint was proposed, which agreed well with the experimental results.
ISSN:2075-5309