A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking

Recording scalp electroencephalography (EEG) during human motion can introduce motion artifacts. Repetitive head movements can generate artifact patterns across scalp EEG sensors. There are many methods for identifying and rejecting bad channels and independent components from EEG datasets, but ther...

Full description

Bibliographic Details
Published in:Frontiers in Neuroscience
Main Authors: Anderson S. Oliveira, Bryan R. Schlink, W. David Hairston, Peter König, Daniel P. Ferris
Format: Article
Language:English
Published: Frontiers Media S.A. 2017-04-01
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fnins.2017.00225/full
_version_ 1856970961077665792
author Anderson S. Oliveira
Anderson S. Oliveira
Bryan R. Schlink
W. David Hairston
Peter König
Peter König
Daniel P. Ferris
author_facet Anderson S. Oliveira
Anderson S. Oliveira
Bryan R. Schlink
W. David Hairston
Peter König
Peter König
Daniel P. Ferris
author_sort Anderson S. Oliveira
collection DOAJ
container_title Frontiers in Neuroscience
description Recording scalp electroencephalography (EEG) during human motion can introduce motion artifacts. Repetitive head movements can generate artifact patterns across scalp EEG sensors. There are many methods for identifying and rejecting bad channels and independent components from EEG datasets, but there is a lack of methods dedicated to evaluate specific intra-channel amplitude patterns for identifying motion-related artifacts. In this study, we proposed a template correlation rejection (TCR) as a novel method for identifying and rejecting EEG channels and independent components carrying motion-related artifacts. We recorded EEG data from 10 subjects during treadmill walking. The template correlation rejection method consists of creating templates of amplitude patterns and determining the fraction of total epochs presenting relevant correlation to the template. For EEG channels, the template correlation rejection removed channels presenting the majority of epochs (>75%) correlated to the template, and presenting pronounced amplitude in comparison to all recorded channels. For independent components, the template correlation rejection removed components presenting the majority of epochs correlated to the template. Evaluation of scalp maps and power spectra confirmed low neural content for the rejected components. We found that channels identified for rejection contained ~60% higher delta power, and had spectral properties locked to the gait phases. After rejecting the identified channels and running independent component analysis on the EEG datasets, the proposed method identified 4.3 ± 1.8 independent components (out of 198 ± 12) with substantive motion-related artifacts. These results indicate that template correlation rejection is an effective method for rejecting EEG channels contaminated with motion-related artifact during human locomotion.
format Article
id doaj-art-92ef42e3ff0a43d2b348aa205ea1d010
institution Directory of Open Access Journals
issn 1662-453X
language English
publishDate 2017-04-01
publisher Frontiers Media S.A.
record_format Article
spelling doaj-art-92ef42e3ff0a43d2b348aa205ea1d0102025-08-19T20:00:15ZengFrontiers Media S.A.Frontiers in Neuroscience1662-453X2017-04-011110.3389/fnins.2017.00225234297A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during WalkingAnderson S. Oliveira0Anderson S. Oliveira1Bryan R. Schlink2W. David Hairston3Peter König4Peter König5Daniel P. Ferris6Human Neuromechanics Laboratory, School of Kinesiology, University of MichiganAnn Arbor, MI, USADepartment of Materials and Production, Aalborg UniversityAalborg, DenmarkDepartment of Materials and Production, Aalborg UniversityAalborg, DenmarkU.S. Army Research Laboratory, Aberdeen Proving GroundAberdeen, MD, USAInstitute of Cognitive Science, University of OsnabrückOsnabrück, GermanyDepartment of Neurophysiology and Pathophysiology, University Medical Center Hamburg-EppendorfHamburg, GermanyHuman Neuromechanics Laboratory, School of Kinesiology, University of MichiganAnn Arbor, MI, USARecording scalp electroencephalography (EEG) during human motion can introduce motion artifacts. Repetitive head movements can generate artifact patterns across scalp EEG sensors. There are many methods for identifying and rejecting bad channels and independent components from EEG datasets, but there is a lack of methods dedicated to evaluate specific intra-channel amplitude patterns for identifying motion-related artifacts. In this study, we proposed a template correlation rejection (TCR) as a novel method for identifying and rejecting EEG channels and independent components carrying motion-related artifacts. We recorded EEG data from 10 subjects during treadmill walking. The template correlation rejection method consists of creating templates of amplitude patterns and determining the fraction of total epochs presenting relevant correlation to the template. For EEG channels, the template correlation rejection removed channels presenting the majority of epochs (>75%) correlated to the template, and presenting pronounced amplitude in comparison to all recorded channels. For independent components, the template correlation rejection removed components presenting the majority of epochs correlated to the template. Evaluation of scalp maps and power spectra confirmed low neural content for the rejected components. We found that channels identified for rejection contained ~60% higher delta power, and had spectral properties locked to the gait phases. After rejecting the identified channels and running independent component analysis on the EEG datasets, the proposed method identified 4.3 ± 1.8 independent components (out of 198 ± 12) with substantive motion-related artifacts. These results indicate that template correlation rejection is an effective method for rejecting EEG channels contaminated with motion-related artifact during human locomotion.http://journal.frontiersin.org/article/10.3389/fnins.2017.00225/fullEEGartifactswalkinglocomotionsignal processingmobile-brain imaging
spellingShingle Anderson S. Oliveira
Anderson S. Oliveira
Bryan R. Schlink
W. David Hairston
Peter König
Peter König
Daniel P. Ferris
A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
EEG
artifacts
walking
locomotion
signal processing
mobile-brain imaging
title A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
title_full A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
title_fullStr A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
title_full_unstemmed A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
title_short A Channel Rejection Method for Attenuating Motion-Related Artifacts in EEG Recordings during Walking
title_sort channel rejection method for attenuating motion related artifacts in eeg recordings during walking
topic EEG
artifacts
walking
locomotion
signal processing
mobile-brain imaging
url http://journal.frontiersin.org/article/10.3389/fnins.2017.00225/full
work_keys_str_mv AT andersonsoliveira achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT andersonsoliveira achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT bryanrschlink achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT wdavidhairston achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT peterkonig achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT peterkonig achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT danielpferris achannelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT andersonsoliveira channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT andersonsoliveira channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT bryanrschlink channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT wdavidhairston channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT peterkonig channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT peterkonig channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking
AT danielpferris channelrejectionmethodforattenuatingmotionrelatedartifactsineegrecordingsduringwalking