Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties

Aggregated Norton’s equivalent models, with parallel impedance and current injection at different harmonic frequencies are used to model the distribution grid in harmonic studies. These models are derived based on measurements and/or prior knowledge about the grid. The measurement-based distribution...

Full description

Bibliographic Details
Published in:Energies
Main Authors: Ravi Shankar Singh, Vladimir Ćuk, Sjef Cobben
Format: Article
Language:English
Published: MDPI AG 2020-08-01
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/16/4259
_version_ 1849878549520973824
author Ravi Shankar Singh
Vladimir Ćuk
Sjef Cobben
author_facet Ravi Shankar Singh
Vladimir Ćuk
Sjef Cobben
author_sort Ravi Shankar Singh
collection DOAJ
container_title Energies
description Aggregated Norton’s equivalent models, with parallel impedance and current injection at different harmonic frequencies are used to model the distribution grid in harmonic studies. These models are derived based on measurements and/or prior knowledge about the grid. The measurement-based distribution (sub-)grid impedance estimation method uses harmonic phasors of 3-phase current and voltage measurements to capture the response of the distribution (sub-)grid before and after an event in the utility side of the grid. However, due to increasing non-linear components in the grid, knowledge about uncertainty in parameters of such equivalent models which intrinsically describe a linear grid becomes important. The aim of this paper is to present two novel methods to calculate the uncertainty of the measurement-based Norton’s equivalent harmonic model of the distribution (sub-)grids as seen from the utility side at the Point of Common Coupling (PCC). The impedance and the uncertainty calculations are demonstrated on a simulated network.
format Article
id doaj-art-9dbd3cfe81cf46c8babb76d5eda0b933
institution Directory of Open Access Journals
issn 1996-1073
language English
publishDate 2020-08-01
publisher MDPI AG
record_format Article
spelling doaj-art-9dbd3cfe81cf46c8babb76d5eda0b9332025-08-20T01:10:43ZengMDPI AGEnergies1996-10732020-08-011316425910.3390/en13164259Measurement-Based Distribution Grid Harmonic Impedance Models and Their UncertaintiesRavi Shankar Singh0Vladimir Ćuk1Sjef Cobben2Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The NetherlandsDepartment of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The NetherlandsDepartment of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The NetherlandsAggregated Norton’s equivalent models, with parallel impedance and current injection at different harmonic frequencies are used to model the distribution grid in harmonic studies. These models are derived based on measurements and/or prior knowledge about the grid. The measurement-based distribution (sub-)grid impedance estimation method uses harmonic phasors of 3-phase current and voltage measurements to capture the response of the distribution (sub-)grid before and after an event in the utility side of the grid. However, due to increasing non-linear components in the grid, knowledge about uncertainty in parameters of such equivalent models which intrinsically describe a linear grid becomes important. The aim of this paper is to present two novel methods to calculate the uncertainty of the measurement-based Norton’s equivalent harmonic model of the distribution (sub-)grids as seen from the utility side at the Point of Common Coupling (PCC). The impedance and the uncertainty calculations are demonstrated on a simulated network.https://www.mdpi.com/1996-1073/13/16/4259customer side impedanceharmonic distortionharmonic contributionpower qualitysub-grid impedance
spellingShingle Ravi Shankar Singh
Vladimir Ćuk
Sjef Cobben
Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
customer side impedance
harmonic distortion
harmonic contribution
power quality
sub-grid impedance
title Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
title_full Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
title_fullStr Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
title_full_unstemmed Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
title_short Measurement-Based Distribution Grid Harmonic Impedance Models and Their Uncertainties
title_sort measurement based distribution grid harmonic impedance models and their uncertainties
topic customer side impedance
harmonic distortion
harmonic contribution
power quality
sub-grid impedance
url https://www.mdpi.com/1996-1073/13/16/4259
work_keys_str_mv AT ravishankarsingh measurementbaseddistributiongridharmonicimpedancemodelsandtheiruncertainties
AT vladimircuk measurementbaseddistributiongridharmonicimpedancemodelsandtheiruncertainties
AT sjefcobben measurementbaseddistributiongridharmonicimpedancemodelsandtheiruncertainties