Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular...

Full description

Bibliographic Details
Published in:Texas Heart Institute Journal
Main Authors: Salim N. Najjar, MD, Michael A. Bruno, MD, Wilson W. Lam, MD
Format: Article
Language:English
Published: The Texas Heart Institute 2024-04-01
Subjects:
Online Access:https://meridian.allenpress.com/thij/article-pdf/doi/10.14503/THIJ-23-8268/3347762/i1526-6702-51-1-e238268.pdf
_version_ 1850411377473093632
author Salim N. Najjar, MD
Michael A. Bruno, MD
Wilson W. Lam, MD
author_facet Salim N. Najjar, MD
Michael A. Bruno, MD
Wilson W. Lam, MD
author_sort Salim N. Najjar, MD
collection DOAJ
container_title Texas Heart Institute Journal
description This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.
format Article
id doaj-art-a270ecaeb2fb4601acf705d2326ef077
institution Directory of Open Access Journals
issn 1526-6702
language English
publishDate 2024-04-01
publisher The Texas Heart Institute
record_format Article
spelling doaj-art-a270ecaeb2fb4601acf705d2326ef0772025-08-19T22:46:36ZengThe Texas Heart InstituteTexas Heart Institute Journal1526-67022024-04-015111610.14503/THIJ-23-8268i1526-6702-51-1-e238268Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker ImplantationSalim N. Najjar, MD0Michael A. Bruno, MD1Wilson W. Lam, MD21 Department of Medicine, Baylor College of Medicine, Houston, Texas2 Department of Pediatrics, Division of Pediatric Cardiology, Baylor College of Medicine, Houston, Texas1 Department of Medicine, Baylor College of Medicine, Houston, TexasThis report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.https://meridian.allenpress.com/thij/article-pdf/doi/10.14503/THIJ-23-8268/3347762/i1526-6702-51-1-e238268.pdfelectrophysiologypacemaker, artificialheart conduction systematrioventricular block
spellingShingle Salim N. Najjar, MD
Michael A. Bruno, MD
Wilson W. Lam, MD
Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
electrophysiology
pacemaker, artificial
heart conduction system
atrioventricular block
title Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
title_full Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
title_fullStr Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
title_full_unstemmed Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
title_short Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
title_sort transient 2 1 atrioventricular block with peri conduction system pacing after leadless pacemaker implantation
topic electrophysiology
pacemaker, artificial
heart conduction system
atrioventricular block
url https://meridian.allenpress.com/thij/article-pdf/doi/10.14503/THIJ-23-8268/3347762/i1526-6702-51-1-e238268.pdf
work_keys_str_mv AT salimnnajjarmd transient21atrioventricularblockwithpericonductionsystempacingafterleadlesspacemakerimplantation
AT michaelabrunomd transient21atrioventricularblockwithpericonductionsystempacingafterleadlesspacemakerimplantation
AT wilsonwlammd transient21atrioventricularblockwithpericonductionsystempacingafterleadlesspacemakerimplantation