Variability of Microcystin-LR Standards Available from Seven Commercial Vendors

Microcystins (MCs) are a large group of heptapeptide cyanobacterial toxins commonly produced in harmful algal blooms (HABs) and associated with adverse health effects in wildlife, livestock, pets, and humans. MC chemical standards are extracted from cyanobacteria biomass rather than produced synthet...

Full description

Bibliographic Details
Published in:Toxins
Main Authors: Donna Hill, Johnsie Lang, James McCord, Mark Strynar, Charlita Rosal, Judith Schmid, Thanh-Thao Le, Neil Chernoff
Format: Article
Language:English
Published: MDPI AG 2022-10-01
Subjects:
Online Access:https://www.mdpi.com/2072-6651/14/10/705
_version_ 1850381685819965440
author Donna Hill
Johnsie Lang
James McCord
Mark Strynar
Charlita Rosal
Judith Schmid
Thanh-Thao Le
Neil Chernoff
author_facet Donna Hill
Johnsie Lang
James McCord
Mark Strynar
Charlita Rosal
Judith Schmid
Thanh-Thao Le
Neil Chernoff
author_sort Donna Hill
collection DOAJ
container_title Toxins
description Microcystins (MCs) are a large group of heptapeptide cyanobacterial toxins commonly produced in harmful algal blooms (HABs) and associated with adverse health effects in wildlife, livestock, pets, and humans. MC chemical standards are extracted from cyanobacteria biomass rather than produced synthetically and are used in water assessment methods and toxicological studies. MC standards are generally supplied in less than 1 mg quantities, and verification of the mass can only be accomplished by analytical chemistry methods using a certified reference of the specific MC for comparison. Analytical quantification of MCs in environmental samples and toxicology studies using accurate doses of test chemicals administered to experimental animals rely on the availability and accuracy of chemical standards. To check the accuracy and purity of available standards, seven individual microcystin-LR (MCLR) standards were purchased from separate commercial vendors and analyzed to determine the actual mass supplied and identify the presence of potential contaminants. To determine the effect of varying toxin mass in toxicological studies, each MCLR standard was administered to CD-1 mice in doses based on mass purchased, by a single 40 µg/kg intraperitoneal injection. The measured mass purchased varied from the vendor label mass by more than 35% for two of the seven MCLR standards. Contaminants, including trifluoroacetic acid (TFA), were identified in four of the seven samples. Comparative in vivo hepatotoxicity between vendor samples closely reflected the actual amount of MCLR present in each standard and demonstrated the toxicological impact of varying cyanotoxin mass.
format Article
id doaj-art-af83ea73b42c4e90a986d819c19bdb13
institution Directory of Open Access Journals
issn 2072-6651
language English
publishDate 2022-10-01
publisher MDPI AG
record_format Article
spelling doaj-art-af83ea73b42c4e90a986d819c19bdb132025-08-19T22:57:20ZengMDPI AGToxins2072-66512022-10-01141070510.3390/toxins14100705Variability of Microcystin-LR Standards Available from Seven Commercial VendorsDonna Hill0Johnsie Lang1James McCord2Mark Strynar3Charlita Rosal4Judith Schmid5Thanh-Thao Le6Neil Chernoff7Center for Public Health and Environmental Assessment, United States Environmental Protection Agency, Research Triangle Park, NC 27711, USAArcadis (United States), 4204 Technology Dr, Durham, NC 27704, USACenter for Environmental Measurement and Modeling, United States Environmental Protection Agency, Research Triangle Park, NC 27711, USACenter for Public Health and Environmental Assessment, United States Environmental Protection Agency, Research Triangle Park, NC 27711, USAIndependent Researcher, Las Vegas, NV 89146, USACenter for Public Health and Environmental Assessment, United States Environmental Protection Agency, Research Triangle Park, NC 27711, USAAlmac Group, Durham, NC 27704, USAIndependent Researcher, Raleigh, NC 27612, USAMicrocystins (MCs) are a large group of heptapeptide cyanobacterial toxins commonly produced in harmful algal blooms (HABs) and associated with adverse health effects in wildlife, livestock, pets, and humans. MC chemical standards are extracted from cyanobacteria biomass rather than produced synthetically and are used in water assessment methods and toxicological studies. MC standards are generally supplied in less than 1 mg quantities, and verification of the mass can only be accomplished by analytical chemistry methods using a certified reference of the specific MC for comparison. Analytical quantification of MCs in environmental samples and toxicology studies using accurate doses of test chemicals administered to experimental animals rely on the availability and accuracy of chemical standards. To check the accuracy and purity of available standards, seven individual microcystin-LR (MCLR) standards were purchased from separate commercial vendors and analyzed to determine the actual mass supplied and identify the presence of potential contaminants. To determine the effect of varying toxin mass in toxicological studies, each MCLR standard was administered to CD-1 mice in doses based on mass purchased, by a single 40 µg/kg intraperitoneal injection. The measured mass purchased varied from the vendor label mass by more than 35% for two of the seven MCLR standards. Contaminants, including trifluoroacetic acid (TFA), were identified in four of the seven samples. Comparative in vivo hepatotoxicity between vendor samples closely reflected the actual amount of MCLR present in each standard and demonstrated the toxicological impact of varying cyanotoxin mass.https://www.mdpi.com/2072-6651/14/10/705microcystin-LRcommercial cyanotoxin standardmass accuracypurity
spellingShingle Donna Hill
Johnsie Lang
James McCord
Mark Strynar
Charlita Rosal
Judith Schmid
Thanh-Thao Le
Neil Chernoff
Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
microcystin-LR
commercial cyanotoxin standard
mass accuracy
purity
title Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
title_full Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
title_fullStr Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
title_full_unstemmed Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
title_short Variability of Microcystin-LR Standards Available from Seven Commercial Vendors
title_sort variability of microcystin lr standards available from seven commercial vendors
topic microcystin-LR
commercial cyanotoxin standard
mass accuracy
purity
url https://www.mdpi.com/2072-6651/14/10/705
work_keys_str_mv AT donnahill variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT johnsielang variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT jamesmccord variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT markstrynar variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT charlitarosal variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT judithschmid variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT thanhthaole variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors
AT neilchernoff variabilityofmicrocystinlrstandardsavailablefromsevencommercialvendors