Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry

Abstract: During the analyses of ore and rock samples by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS), many residues were formed in the tubes in which the hydride was generated, transport channelled and atomized. If a certain amount of the residues accumulat, they can distinctively a...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Yankuang ceshi
المؤلفون الرئيسيون: HE Gui, CHANG Ji-xiu, ZHOU Xiao-run, WANG Lu-jun
التنسيق: مقال
اللغة:الإنجليزية
منشور في: Science Press, PR China 2013-03-01
الموضوعات:
الوصول للمادة أونلاين:http://www.ykcs.ac.cn/en/article/id/d860f410-b1eb-4b84-a4c1-85ff2238d867
_version_ 1852655734484893696
author HE Gui
CHANG Ji-xiu
ZHOU Xiao-run
WANG Lu-jun
author_facet HE Gui
CHANG Ji-xiu
ZHOU Xiao-run
WANG Lu-jun
author_sort HE Gui
collection DOAJ
container_title Yankuang ceshi
description Abstract: During the analyses of ore and rock samples by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS), many residues were formed in the tubes in which the hydride was generated, transport channelled and atomized. If a certain amount of the residues accumulat, they can distinctively affect the detection sensitivity of Se and Te. Many coexisting ingredients in the samples have a large influence on the detection of Se and Te by HG-AFS. In this article, to avoid interference from these ingredients, the series of standard solutions prepared with highly pure material were used. The standard solutions were tested with used tubes and cleaned ones. Through comparison of the data of the standard solutions, it was demonstrated that the residues in the instrument affected the detection of Se and Te by making the detection sensibility lower and the linear correlation coefficient smaller. The residues were analyzed with Atomic Fluorescence Spectrometry, Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission Spectrometry. On the basis of the analytical results of the residues, Ti, Cu, As, Sb and Bi have great effect on the detection sensitivity and the linear correlation coefficient of Se and Te. These elements are a part of the coexisting interferences mentioned in literatures. When the tubes were cleaned, the measured quality was remarkably improved with higher sensitivity, and the linear correlation coefficient was more than 0.9995. According to the data obtained in this study, indications are that the analysis of residue components in the tubes is one of the effective methods to control the interference of HG-AFS.
format Article
id doaj-art-d36dbd4a0f334a8cbe5eaae49d7ec6ae
institution Directory of Open Access Journals
issn 0254-5357
language English
publishDate 2013-03-01
publisher Science Press, PR China
record_format Article
spelling doaj-art-d36dbd4a0f334a8cbe5eaae49d7ec6ae2025-08-19T21:39:04ZengScience Press, PR ChinaYankuang ceshi0254-53572013-03-01322229243ykcs-32-2-229Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence SpectrometryHE Gui0CHANG Ji-xiu1ZHOU Xiao-run2WANG Lu-jun3Regional Geological Surveying Team, Sichuan Geology and Mineral Resources Bureau, Shuangliu 610213, ChinaRegional Geological Surveying Team, Sichuan Geology and Mineral Resources Bureau, Shuangliu 610213, ChinaRegional Geological Surveying Team, Sichuan Geology and Mineral Resources Bureau, Shuangliu 610213, ChinaRegional Geological Surveying Team, Sichuan Geology and Mineral Resources Bureau, Shuangliu 610213, ChinaAbstract: During the analyses of ore and rock samples by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS), many residues were formed in the tubes in which the hydride was generated, transport channelled and atomized. If a certain amount of the residues accumulat, they can distinctively affect the detection sensitivity of Se and Te. Many coexisting ingredients in the samples have a large influence on the detection of Se and Te by HG-AFS. In this article, to avoid interference from these ingredients, the series of standard solutions prepared with highly pure material were used. The standard solutions were tested with used tubes and cleaned ones. Through comparison of the data of the standard solutions, it was demonstrated that the residues in the instrument affected the detection of Se and Te by making the detection sensibility lower and the linear correlation coefficient smaller. The residues were analyzed with Atomic Fluorescence Spectrometry, Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission Spectrometry. On the basis of the analytical results of the residues, Ti, Cu, As, Sb and Bi have great effect on the detection sensitivity and the linear correlation coefficient of Se and Te. These elements are a part of the coexisting interferences mentioned in literatures. When the tubes were cleaned, the measured quality was remarkably improved with higher sensitivity, and the linear correlation coefficient was more than 0.9995. According to the data obtained in this study, indications are that the analysis of residue components in the tubes is one of the effective methods to control the interference of HG-AFS.http://www.ykcs.ac.cn/en/article/id/d860f410-b1eb-4b84-a4c1-85ff2238d867seleniumtelluriumhydride generation-atomic fluorescence spectrometryresidues in instrument
spellingShingle HE Gui
CHANG Ji-xiu
ZHOU Xiao-run
WANG Lu-jun
Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
selenium
tellurium
hydride generation-atomic fluorescence spectrometry
residues in instrument
title Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
title_full Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
title_fullStr Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
title_full_unstemmed Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
title_short Discussion on Influence of Residues in Instruments on Detection of Selenium and Tellurium by Hydride Generation-Atomic Fluorescence Spectrometry
title_sort discussion on influence of residues in instruments on detection of selenium and tellurium by hydride generation atomic fluorescence spectrometry
topic selenium
tellurium
hydride generation-atomic fluorescence spectrometry
residues in instrument
url http://www.ykcs.ac.cn/en/article/id/d860f410-b1eb-4b84-a4c1-85ff2238d867
work_keys_str_mv AT hegui discussiononinfluenceofresiduesininstrumentsondetectionofseleniumandtelluriumbyhydridegenerationatomicfluorescencespectrometry
AT changjixiu discussiononinfluenceofresiduesininstrumentsondetectionofseleniumandtelluriumbyhydridegenerationatomicfluorescencespectrometry
AT zhouxiaorun discussiononinfluenceofresiduesininstrumentsondetectionofseleniumandtelluriumbyhydridegenerationatomicfluorescencespectrometry
AT wanglujun discussiononinfluenceofresiduesininstrumentsondetectionofseleniumandtelluriumbyhydridegenerationatomicfluorescencespectrometry