Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy
Purpose: To evaluate the differences in intraocular lens (IOL) decentration, tilt, and lenticular astigmatism between Yamane’s IOL fixations combined with pars plana vitrectomy (PPV) or anterior vitrectomy (AV), as well as compare those results with standard phacoemulsification surgery at the sixth...
| 發表在: | Indian Journal of Ophthalmology |
|---|---|
| Main Authors: | , , , , , |
| 格式: | Article |
| 語言: | 英语 |
| 出版: |
Wolters Kluwer Medknow Publications
2025-06-01
|
| 主題: | |
| 在線閱讀: | https://journals.lww.com/10.4103/IJO.IJO_2927_24 |
| _version_ | 1849447952372727808 |
|---|---|
| author | Cemile Ucgul Atilgan Kemal Tekin Merve Temmuz Aydugan Pinar Kosekahya Ali Kosekahya Mehmet Citirik |
| author_facet | Cemile Ucgul Atilgan Kemal Tekin Merve Temmuz Aydugan Pinar Kosekahya Ali Kosekahya Mehmet Citirik |
| author_sort | Cemile Ucgul Atilgan |
| collection | DOAJ |
| container_title | Indian Journal of Ophthalmology |
| description | Purpose:
To evaluate the differences in intraocular lens (IOL) decentration, tilt, and lenticular astigmatism between Yamane’s IOL fixations combined with pars plana vitrectomy (PPV) or anterior vitrectomy (AV), as well as compare those results with standard phacoemulsification surgery at the sixth month.
Methods:
This prospective longitudinal comparative study included 20 eyes treated with Yamane’s IOL fixation combined with AV (AV group), 20 eyes treated with Yamane’s IOL fixation combined with PPV (PPV group), and 20 eyes that underwent standard phacoemulsification with the implantation of a foldable IOL in the capsular bag as controls (Phaco group). IOL decentration, tilt, and lenticular astigmatism values were compared between the groups.
Results:
The horizontal tilt angle was statistically significantly lower in the Phaco group compared to the PPV and AV groups, while no significant differences existed between the PPV and AV groups. The mean values of horizontal decentration, vertical decentration, and vertical tilt 6 months postoperatively showed no statistically significant differences between the three groups (P > 0.05 for all), while all parameters were lower in the Phaco group. Moreover, no statistically significant differences existed in accordance with the mean lenticular astigmatism 6 months postoperatively between the three groups (P = 0.969).
Conclusion:
AV or PPV combined with Yamane’s technique exhibited similar IOL decentration, tilt, and lenticular astigmatism at 6 months. |
| format | Article |
| id | doaj-art-d7765259e8a24aa6b5a7b37dcfd7582e |
| institution | Directory of Open Access Journals |
| issn | 0301-4738 1998-3689 |
| language | English |
| publishDate | 2025-06-01 |
| publisher | Wolters Kluwer Medknow Publications |
| record_format | Article |
| spelling | doaj-art-d7765259e8a24aa6b5a7b37dcfd7582e2025-08-20T03:29:21ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892025-06-0173Suppl 3S466S47110.4103/IJO.IJO_2927_24Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomyCemile Ucgul AtilganKemal TekinMerve Temmuz AyduganPinar KosekahyaAli KosekahyaMehmet CitirikPurpose: To evaluate the differences in intraocular lens (IOL) decentration, tilt, and lenticular astigmatism between Yamane’s IOL fixations combined with pars plana vitrectomy (PPV) or anterior vitrectomy (AV), as well as compare those results with standard phacoemulsification surgery at the sixth month. Methods: This prospective longitudinal comparative study included 20 eyes treated with Yamane’s IOL fixation combined with AV (AV group), 20 eyes treated with Yamane’s IOL fixation combined with PPV (PPV group), and 20 eyes that underwent standard phacoemulsification with the implantation of a foldable IOL in the capsular bag as controls (Phaco group). IOL decentration, tilt, and lenticular astigmatism values were compared between the groups. Results: The horizontal tilt angle was statistically significantly lower in the Phaco group compared to the PPV and AV groups, while no significant differences existed between the PPV and AV groups. The mean values of horizontal decentration, vertical decentration, and vertical tilt 6 months postoperatively showed no statistically significant differences between the three groups (P > 0.05 for all), while all parameters were lower in the Phaco group. Moreover, no statistically significant differences existed in accordance with the mean lenticular astigmatism 6 months postoperatively between the three groups (P = 0.969). Conclusion: AV or PPV combined with Yamane’s technique exhibited similar IOL decentration, tilt, and lenticular astigmatism at 6 months.https://journals.lww.com/10.4103/IJO.IJO_2927_24intraocular lens decentrationintraocular lens tiltpars plana vitrectomysutureless scleral fixationyamane’s technique |
| spellingShingle | Cemile Ucgul Atilgan Kemal Tekin Merve Temmuz Aydugan Pinar Kosekahya Ali Kosekahya Mehmet Citirik Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy intraocular lens decentration intraocular lens tilt pars plana vitrectomy sutureless scleral fixation yamane’s technique |
| title | Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy |
| title_full | Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy |
| title_fullStr | Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy |
| title_full_unstemmed | Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy |
| title_short | Intraocular lens position outcomes in modified Yamane’s technique: The comparison of anterior vitrectomy versus pars plana vitrectomy |
| title_sort | intraocular lens position outcomes in modified yamane s technique the comparison of anterior vitrectomy versus pars plana vitrectomy |
| topic | intraocular lens decentration intraocular lens tilt pars plana vitrectomy sutureless scleral fixation yamane’s technique |
| url | https://journals.lww.com/10.4103/IJO.IJO_2927_24 |
| work_keys_str_mv | AT cemileucgulatilgan intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy AT kemaltekin intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy AT mervetemmuzaydugan intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy AT pinarkosekahya intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy AT alikosekahya intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy AT mehmetcitirik intraocularlenspositionoutcomesinmodifiedyamanestechniquethecomparisonofanteriorvitrectomyversusparsplanavitrectomy |
