Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction
Rotator cuff tears (RCTs) are common injuries, and treatments for irreparable massive RCTs are still controversial. Among the various treatment options for irreparable massive RCTs, rotator cuff reconstruction is considered a reasonable approach, yet there is no consensus on the optimal reconstructi...
| Published in: | Arthroscopy Techniques |
|---|---|
| Main Authors: | , , , , , , |
| Format: | Article |
| Language: | English |
| Published: |
Elsevier
2025-08-01
|
| Online Access: | http://www.sciencedirect.com/science/article/pii/S2212628725002695 |
| _version_ | 1849326640818028544 |
|---|---|
| author | Yi Li, M.Med. Wenbo Yang, M.D., Ph.D. Fashuai Wu, M.D., Ph.D. Yizhong Peng, M.D., Ph.D. Chunqing Meng, M.D., Ph.D. Hong Wang, M.D., Ph.D. Wei Huang, M.D., Ph.D. |
| author_facet | Yi Li, M.Med. Wenbo Yang, M.D., Ph.D. Fashuai Wu, M.D., Ph.D. Yizhong Peng, M.D., Ph.D. Chunqing Meng, M.D., Ph.D. Hong Wang, M.D., Ph.D. Wei Huang, M.D., Ph.D. |
| author_sort | Yi Li, M.Med. |
| collection | DOAJ |
| container_title | Arthroscopy Techniques |
| description | Rotator cuff tears (RCTs) are common injuries, and treatments for irreparable massive RCTs are still controversial. Among the various treatment options for irreparable massive RCTs, rotator cuff reconstruction is considered a reasonable approach, yet there is no consensus on the optimal reconstruction technique. In this article, we introduce a suture anchor onlay technique for rotator cuff reconstruction. In our technique, the peroneus longus tendon is harvested and prepared as an autograft, and on the lateral side, a suture anchor is implanted to fix the autograft on the greater tuberosity surface. The key steps of our technique are performing anchor implantation to ensure that the autografts are fixed tightly on the greater tuberosity surface, knotting the sutures from the medial-row anchors that we pre-implanted at the midsubstance of the autograft to provide additional fixation, and finally, achieving “onlay” fixation of the autografts. Our technique can effectively reduce surgical time, simplify the reconstruction procedure, and has good clinical application value. |
| format | Article |
| id | doaj-art-dcd592b4cccd428ab749983c1b6786df |
| institution | Directory of Open Access Journals |
| issn | 2212-6287 |
| language | English |
| publishDate | 2025-08-01 |
| publisher | Elsevier |
| record_format | Article |
| spelling | doaj-art-dcd592b4cccd428ab749983c1b6786df2025-09-01T07:32:50ZengElsevierArthroscopy Techniques2212-62872025-08-0114810370010.1016/j.eats.2025.103700Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear ReconstructionYi Li, M.Med.0Wenbo Yang, M.D., Ph.D.1Fashuai Wu, M.D., Ph.D.2Yizhong Peng, M.D., Ph.D.3Chunqing Meng, M.D., Ph.D.4Hong Wang, M.D., Ph.D.5Wei Huang, M.D., Ph.D.6Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaAddress correspondence to Wei Huang, M.D., Ph.D., Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, Hubei 430022, China.; Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, ChinaRotator cuff tears (RCTs) are common injuries, and treatments for irreparable massive RCTs are still controversial. Among the various treatment options for irreparable massive RCTs, rotator cuff reconstruction is considered a reasonable approach, yet there is no consensus on the optimal reconstruction technique. In this article, we introduce a suture anchor onlay technique for rotator cuff reconstruction. In our technique, the peroneus longus tendon is harvested and prepared as an autograft, and on the lateral side, a suture anchor is implanted to fix the autograft on the greater tuberosity surface. The key steps of our technique are performing anchor implantation to ensure that the autografts are fixed tightly on the greater tuberosity surface, knotting the sutures from the medial-row anchors that we pre-implanted at the midsubstance of the autograft to provide additional fixation, and finally, achieving “onlay” fixation of the autografts. Our technique can effectively reduce surgical time, simplify the reconstruction procedure, and has good clinical application value.http://www.sciencedirect.com/science/article/pii/S2212628725002695 |
| spellingShingle | Yi Li, M.Med. Wenbo Yang, M.D., Ph.D. Fashuai Wu, M.D., Ph.D. Yizhong Peng, M.D., Ph.D. Chunqing Meng, M.D., Ph.D. Hong Wang, M.D., Ph.D. Wei Huang, M.D., Ph.D. Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title | Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title_full | Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title_fullStr | Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title_full_unstemmed | Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title_short | Suture Anchor Onlay Technique: Peroneus Longus Autograft Augmentation for Arthroscopic Irreparable Massive Rotator Cuff Tear Reconstruction |
| title_sort | suture anchor onlay technique peroneus longus autograft augmentation for arthroscopic irreparable massive rotator cuff tear reconstruction |
| url | http://www.sciencedirect.com/science/article/pii/S2212628725002695 |
| work_keys_str_mv | AT yilimmed sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT wenboyangmdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT fashuaiwumdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT yizhongpengmdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT chunqingmengmdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT hongwangmdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction AT weihuangmdphd sutureanchoronlaytechniqueperoneuslongusautograftaugmentationforarthroscopicirreparablemassiverotatorcufftearreconstruction |
