Performance Enhancement of Double Tube Heat Exchanger Using Coiled Fins

The effect of inserting coil wire in the shell side of a doublepipe heat exchanger on the heat transfer and pressure drop areexperimentally investigated. The experiments are performedusing water as the hot and cold working fluid under the turbulentflow condition. Nine coils with different wire diame...

Full description

Bibliographic Details
Published in:Journal of Engineering Research - Egypt
Main Authors: A. Khalil, S. El-Agouz, A. Zohir, A. Farid
Format: Article
Language:Arabic
Published: Faculty of Engineering, Tanta University 2019-03-01
Subjects:
Online Access:https://erjeng.journals.ekb.eg/article_125492_cab97ce75c72d01be781e73f94f2a47c.pdf
Description
Summary:The effect of inserting coil wire in the shell side of a doublepipe heat exchanger on the heat transfer and pressure drop areexperimentally investigated. The experiments are performedusing water as the hot and cold working fluid under the turbulentflow condition. Nine coils with different wire diameter (dw = 2, 4and 6 mm) and different coil pitch ratio (P/ dw = 2.5, 5 and 7.5)are used in the study. Results presented an increasing up to 1.59in the heat transfer coefficient while the pressure drop increased10 times compared with the smooth pipe. Results also showedthat the increase in the heat gain is very big than the loss in thepumping power.