Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance

BACKGROUND: Several studies show that gestational age estimation during the third trimester of pregnancy using fetal transcerebellar diameter is superior to that measured using fetal biometry (biparietal diameter, head circumference, abdominal circumference, and femur diaphysis length). However, the...

Full description

Bibliographic Details
Published in:AJOG Global Reports
Main Authors: Delayehu Bekele, MD, MPH, Wondimu Gudu, MD, MPH, Mekitie Wondafrash, MD, PhD, Abdulfetah Abdulkadir Abdosh, MD, Abraham Fessehaye Sium, MD
Format: Article
Language:English
Published: Elsevier 2024-02-01
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666577824000017
_version_ 1850363890915868672
author Delayehu Bekele, MD, MPH
Wondimu Gudu, MD, MPH
Mekitie Wondafrash, MD, PhD
Abdulfetah Abdulkadir Abdosh, MD
Abraham Fessehaye Sium, MD
author_facet Delayehu Bekele, MD, MPH
Wondimu Gudu, MD, MPH
Mekitie Wondafrash, MD, PhD
Abdulfetah Abdulkadir Abdosh, MD
Abraham Fessehaye Sium, MD
author_sort Delayehu Bekele, MD, MPH
collection DOAJ
container_title AJOG Global Reports
description BACKGROUND: Several studies show that gestational age estimation during the third trimester of pregnancy using fetal transcerebellar diameter is superior to that measured using fetal biometry (biparietal diameter, head circumference, abdominal circumference, and femur diaphysis length). However, the conclusion of the studies stemmed from findings of correlation and regression statistical tests, which are not the recommended statistical analysis methods for comparing the values of 1 variable as measured by 2 different methods. OBJECTIVE: This study aimed to compare the accuracy of gestational age estimation using transcerebellar diameter to that using fetal biometry during the third trimester of pregnancy using Bland-Altman statistical analysis. STUDY DESIGN: This was a cross-sectional study on pregnant women who presented for routine antenatal care follow-up in the third trimester of pregnancy (28–41 weeks of gestation) at St. Paul's Hospital Millennium Medical College (Ethiopia) between November 1, 2020, and February 28, 2021. Data were collected prospectively using a structured questionnaire on the Open Data Kit. The primary outcome of our study was the mean bias of gestational age estimation (error in estimating gestational age) using transcerebellar diameter and composite fetal biometry (composite gestational age). Data were analyzed using Stata (version 15; StataCorp, College Station, TX). Simple descriptive analysis, Bland-Altman analysis, and the Kendall τa discordance measurement were performed as appropriate. The mean bias (error) and limits of agreement were used to present the significance of the finding. RESULTS: A total of 104 pregnant women in the third trimester were included in the study. The mean error (bias) when transcerebellar diameter was used to estimate the gestational age was 0.65 weeks vs a bias of 1.1 weeks using composite biometry, compared with the gold standard method from crown-lump length (in both cases). The calculated estimated limit of agreement was narrower in the case of transcerebellar diameter than in the case of composite fetal biometry (−3.56 to 2.25 vs −4.73 to 2.53). The Kendall τa discordance measurement revealed that gestational age estimations using composite biometry and crown-lump length were 51% to 70%, respectively, more likely to agree than disagree and that gestational age estimations using transcerebellar diameter and crown-lump length were 62% to 77%, respectively, more likely to agree than to disagree (P≤.001). CONCLUSION: Gestational age estimation using transcerebellar diameter is more accurate than gestational age estimation using composite gestational age (biparietal diameter, head circumference, femur diaphysis length, and abdominal circumference). Transcerebellar diameter should be used to date third-trimester pregnancies with unknown gestational age (unknown last normal menstrual period with no early ultrasound milestone).
format Article
id doaj-art-e183f3cbcd004591ac7cb46c64b6ff24
institution Directory of Open Access Journals
issn 2666-5778
language English
publishDate 2024-02-01
publisher Elsevier
record_format Article
spelling doaj-art-e183f3cbcd004591ac7cb46c64b6ff242025-08-19T23:04:03ZengElsevierAJOG Global Reports2666-57782024-02-014110030710.1016/j.xagr.2024.100307Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a GlanceDelayehu Bekele, MD, MPH0Wondimu Gudu, MD, MPH1Mekitie Wondafrash, MD, PhD2Abdulfetah Abdulkadir Abdosh, MD3Abraham Fessehaye Sium, MD4Department of Obstetrics and Gynecology, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia (Drs Bekele, Gudu, Abdosh, and Sium)Department of Obstetrics and Gynecology, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia (Drs Bekele, Gudu, Abdosh, and Sium)St. Paul's Institute for Reproductive Health and Rights, Addis Ababa, Ethiopia (Dr Wondafrash)Department of Obstetrics and Gynecology, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia (Drs Bekele, Gudu, Abdosh, and Sium)Department of Obstetrics and Gynecology, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia (Drs Bekele, Gudu, Abdosh, and Sium); Corresponding author: Abraham Fessehaye Sium, MD.BACKGROUND: Several studies show that gestational age estimation during the third trimester of pregnancy using fetal transcerebellar diameter is superior to that measured using fetal biometry (biparietal diameter, head circumference, abdominal circumference, and femur diaphysis length). However, the conclusion of the studies stemmed from findings of correlation and regression statistical tests, which are not the recommended statistical analysis methods for comparing the values of 1 variable as measured by 2 different methods. OBJECTIVE: This study aimed to compare the accuracy of gestational age estimation using transcerebellar diameter to that using fetal biometry during the third trimester of pregnancy using Bland-Altman statistical analysis. STUDY DESIGN: This was a cross-sectional study on pregnant women who presented for routine antenatal care follow-up in the third trimester of pregnancy (28–41 weeks of gestation) at St. Paul's Hospital Millennium Medical College (Ethiopia) between November 1, 2020, and February 28, 2021. Data were collected prospectively using a structured questionnaire on the Open Data Kit. The primary outcome of our study was the mean bias of gestational age estimation (error in estimating gestational age) using transcerebellar diameter and composite fetal biometry (composite gestational age). Data were analyzed using Stata (version 15; StataCorp, College Station, TX). Simple descriptive analysis, Bland-Altman analysis, and the Kendall τa discordance measurement were performed as appropriate. The mean bias (error) and limits of agreement were used to present the significance of the finding. RESULTS: A total of 104 pregnant women in the third trimester were included in the study. The mean error (bias) when transcerebellar diameter was used to estimate the gestational age was 0.65 weeks vs a bias of 1.1 weeks using composite biometry, compared with the gold standard method from crown-lump length (in both cases). The calculated estimated limit of agreement was narrower in the case of transcerebellar diameter than in the case of composite fetal biometry (−3.56 to 2.25 vs −4.73 to 2.53). The Kendall τa discordance measurement revealed that gestational age estimations using composite biometry and crown-lump length were 51% to 70%, respectively, more likely to agree than disagree and that gestational age estimations using transcerebellar diameter and crown-lump length were 62% to 77%, respectively, more likely to agree than to disagree (P≤.001). CONCLUSION: Gestational age estimation using transcerebellar diameter is more accurate than gestational age estimation using composite gestational age (biparietal diameter, head circumference, femur diaphysis length, and abdominal circumference). Transcerebellar diameter should be used to date third-trimester pregnancies with unknown gestational age (unknown last normal menstrual period with no early ultrasound milestone).http://www.sciencedirect.com/science/article/pii/S2666577824000017biometrylow-income settingobstetrical ultrasoundpregnancy datingtranscerebellar diameterunknown date
spellingShingle Delayehu Bekele, MD, MPH
Wondimu Gudu, MD, MPH
Mekitie Wondafrash, MD, PhD
Abdulfetah Abdulkadir Abdosh, MD
Abraham Fessehaye Sium, MD
Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
biometry
low-income setting
obstetrical ultrasound
pregnancy dating
transcerebellar diameter
unknown date
title Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
title_full Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
title_fullStr Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
title_full_unstemmed Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
title_short Utilization of third-trimester fetal transcerebellar diameter measurement for gestational age estimation: a comparative study using Bland-Altman analysisAJOG Global Reports at a Glance
title_sort utilization of third trimester fetal transcerebellar diameter measurement for gestational age estimation a comparative study using bland altman analysisajog global reports at a glance
topic biometry
low-income setting
obstetrical ultrasound
pregnancy dating
transcerebellar diameter
unknown date
url http://www.sciencedirect.com/science/article/pii/S2666577824000017
work_keys_str_mv AT delayehubekelemdmph utilizationofthirdtrimesterfetaltranscerebellardiametermeasurementforgestationalageestimationacomparativestudyusingblandaltmananalysisajogglobalreportsataglance
AT wondimugudumdmph utilizationofthirdtrimesterfetaltranscerebellardiametermeasurementforgestationalageestimationacomparativestudyusingblandaltmananalysisajogglobalreportsataglance
AT mekitiewondafrashmdphd utilizationofthirdtrimesterfetaltranscerebellardiametermeasurementforgestationalageestimationacomparativestudyusingblandaltmananalysisajogglobalreportsataglance
AT abdulfetahabdulkadirabdoshmd utilizationofthirdtrimesterfetaltranscerebellardiametermeasurementforgestationalageestimationacomparativestudyusingblandaltmananalysisajogglobalreportsataglance
AT abrahamfessehayesiummd utilizationofthirdtrimesterfetaltranscerebellardiametermeasurementforgestationalageestimationacomparativestudyusingblandaltmananalysisajogglobalreportsataglance