An Inkjet Printed Flexible Electrocorticography (ECoG) Microelectrode Array on a Thin Parylene-C Film
Electrocorticography (ECoG) is a conventional, invasive technique for recording brain signals from the cortical surface using an array of electrodes. In this study, we developed a highly flexible 22-channel ECoG microelectrode array on a thin Parylene film using novel fabrication techniques. Narrow...
| Published in: | Sensors |
|---|---|
| Main Authors: | Yoontae Kim, Stella Alimperti, Paul Choi, Moses Noh |
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2022-02-01
|
| Subjects: | |
| Online Access: | https://www.mdpi.com/1424-8220/22/3/1277 |
Similar Items
Parylene-Based Flexible Microelectrode Arrays for the Electrical Recording of Muscles and the Effect of Electrode Size
by: Bong-Jun Choi, et al.
Published: (2020-10-01)
by: Bong-Jun Choi, et al.
Published: (2020-10-01)
Immunohistological responses in mice implanted with Parylene HT – ITO ECoG devices
by: Miklós Madarász, et al.
Published: (2023-08-01)
by: Miklós Madarász, et al.
Published: (2023-08-01)
Microfabrication of Embedding a Flexible Parylene-Based Microelectrode Array within Body-on-a-Chip
by: Tatsuya Omaki, et al.
Published: (2017-08-01)
by: Tatsuya Omaki, et al.
Published: (2017-08-01)
ECoG Dual Context Network for Brain Machine Interfaces
by: Shunya Nagashima, et al.
Published: (2025-01-01)
by: Shunya Nagashima, et al.
Published: (2025-01-01)
Handcrafted Electrocorticography Electrodes for a Rodent Behavioral Model
by: Nishat Tasnim, et al.
Published: (2016-08-01)
by: Nishat Tasnim, et al.
Published: (2016-08-01)
Prospects of Electrocorticography in Neuropharmacological Studies in Small Laboratory Animals
by: Yuriy I. Sysoev, et al.
Published: (2024-07-01)
by: Yuriy I. Sysoev, et al.
Published: (2024-07-01)
Dynamical criticality during induction of anesthesia in human ECoG recordings
by: Leandro M. Alonso, et al.
Published: (2014-03-01)
by: Leandro M. Alonso, et al.
Published: (2014-03-01)
A Simple Method to Allow Parylene-C Coatings on Gold Substrates
by: Sander van den Driesche, et al.
Published: (2017-08-01)
by: Sander van den Driesche, et al.
Published: (2017-08-01)
Slippery Epidural ECoG Electrode for High-Performance Neural Recording and Interface
by: Md Eshrat E. Alahi, et al.
Published: (2022-11-01)
by: Md Eshrat E. Alahi, et al.
Published: (2022-11-01)
Microwave Plasma-Enhanced Parylene–Metal Multilayer Design from Metal Salts
by: Mirco Weber, et al.
Published: (2022-07-01)
by: Mirco Weber, et al.
Published: (2022-07-01)
Development of a bending test procedure for the characterization of flexible ECoG electrode arrays
by: Kohler Fabian, et al.
Published: (2015-09-01)
by: Kohler Fabian, et al.
Published: (2015-09-01)
Typical somatomotor physiology of the hand is preserved in a patient with an amputated arm: An ECoG case study
by: Max van den Boom, et al.
Published: (2021-01-01)
by: Max van den Boom, et al.
Published: (2021-01-01)
Parylene C as a versatile dielectric material for organic field-effect transistors
by: Tomasz Marszalek, et al.
Published: (2017-07-01)
by: Tomasz Marszalek, et al.
Published: (2017-07-01)
Consistent spectro-spatial features of human ECoG successfully decode naturalistic behavioral states
by: Abdulwahab Alasfour, et al.
Published: (2024-05-01)
by: Abdulwahab Alasfour, et al.
Published: (2024-05-01)
Power Modulations of ECoG Alpha/Beta and Gamma Bands Correlate With Time-Derivative of Force During Hand Grasp
by: Tianxiao Jiang, et al.
Published: (2020-02-01)
by: Tianxiao Jiang, et al.
Published: (2020-02-01)
Artifact Removal in Electrocorticography Devices With Cardiac Contamination
by: K. A. Liyanage, et al.
Published: (2025-01-01)
by: K. A. Liyanage, et al.
Published: (2025-01-01)
Neural Decoding of Single Vowels during Covert Articulation using Electrocorticography
by: Shigeyuki eIkeda, et al.
Published: (2014-03-01)
by: Shigeyuki eIkeda, et al.
Published: (2014-03-01)
Characterization and Analysis of Metal Adhesion to Parylene Polymer Substrate Using Scotch Tape Test for Peripheral Neural Probe
by: Seonho Seok, et al.
Published: (2020-06-01)
by: Seonho Seok, et al.
Published: (2020-06-01)
Transorbital intraoperative electrocorticography-guided surgical resection for medically refractory developmental epileptic encephalopathy with spike-wave activation in sleep
by: Michael E. Baumgartner, et al.
Published: (2024-01-01)
by: Michael E. Baumgartner, et al.
Published: (2024-01-01)
Rapid communication with a P300 matrix speller using electrocorticographic signals (ECoG)
by: Peter eBrunner, et al.
Published: (2011-02-01)
by: Peter eBrunner, et al.
Published: (2011-02-01)
A Fully-Integrated Wireless System for Intracranial Direct Cortical Stimulation, Real-Time Electrocorticography Data Trasmission and Smart Cage for Wireless Battery Recharge
by: Marco ePiangerelli, et al.
Published: (2014-08-01)
by: Marco ePiangerelli, et al.
Published: (2014-08-01)
Inferring Cortical Connectivity From ECoG Signals Using Graph Signal Processing
by: Siddhi Tavildar, et al.
Published: (2019-01-01)
by: Siddhi Tavildar, et al.
Published: (2019-01-01)
DTCNet: finger flexion decoding with three-dimensional ECoG data
by: Fufeng Wang, et al.
Published: (2025-07-01)
by: Fufeng Wang, et al.
Published: (2025-07-01)
ECoG high gamma activity reveals distinct cortical representations of lyrics passages, harmonic and timbre-related changes in a rock song
by: Irene eSturm, et al.
Published: (2014-10-01)
by: Irene eSturm, et al.
Published: (2014-10-01)
Fabrication of Parylene-Coated Microneedle Array Electrode for Wearable ECG Device
by: Afraiz Tariq Satti, et al.
Published: (2020-09-01)
by: Afraiz Tariq Satti, et al.
Published: (2020-09-01)
Progress in the Field of Micro-Electrocorticography
by: Mehdi Shokoueinejad, et al.
Published: (2019-01-01)
by: Mehdi Shokoueinejad, et al.
Published: (2019-01-01)
Histopathological Effects of Parylene C (poly-chloro-p-xylylene) in the Inner Ear
by: Raşit Cevizci, et al.
Published: (2016-06-01)
by: Raşit Cevizci, et al.
Published: (2016-06-01)
Flexible Electrocorticography Electrode Array for Epileptiform Electrical Activity Recording under Glutamate and GABA Modulation on the Primary Somatosensory Cortex of Rats
by: Xinrong Li, et al.
Published: (2020-07-01)
by: Xinrong Li, et al.
Published: (2020-07-01)
Enhancing DNN Models for EEG/ECoG BCI With a Novel Data-Driven Offline Optimization Method
by: Antonios Tragoudaras, et al.
Published: (2023-01-01)
by: Antonios Tragoudaras, et al.
Published: (2023-01-01)
Improved route to a diphenoxide-based precursor for chemical vapour deposition of parylene AF-4
by: Daniel Kast, et al.
Published: (2021-04-01)
by: Daniel Kast, et al.
Published: (2021-04-01)
Annealing Effects of Parylene-Caulked Polydimethylsiloxane as a Substrate of Electrodes
by: Jinmo Jeong, et al.
Published: (2016-12-01)
by: Jinmo Jeong, et al.
Published: (2016-12-01)
Highly controllable and reliable ultra-thin Parylene deposition
by: Yaoping Liu, et al.
Published: (2018-10-01)
by: Yaoping Liu, et al.
Published: (2018-10-01)
Electrocorticography reveals beta desynchronization in the basal ganglia-cortical loop during rest tremor in Parkinson's disease
by: Salman E. Qasim, et al.
Published: (2016-02-01)
by: Salman E. Qasim, et al.
Published: (2016-02-01)
Mechanical properties of thin film Parylene-metal-Parylene devices
by: Curtis Dixon Lee, et al.
Published: (2015-09-01)
by: Curtis Dixon Lee, et al.
Published: (2015-09-01)
Enhanced performance of solution‐processed carbon nanotube transparent electrodes in foldable perovskite solar cells through vertical separation of binders by using eco‐friendly parylene substrate
by: Unsoo Kim, et al.
Published: (2024-07-01)
by: Unsoo Kim, et al.
Published: (2024-07-01)
The effect of duloxetine on ECoG activity of absence-epilepsy model in WAG/Rij rats
by: Hatice Aygün
Published: (2019-09-01)
by: Hatice Aygün
Published: (2019-09-01)
Fabrication of MEMS-based 3D-μECoG-MEAs
by: Deckert Martin, et al.
Published: (2016-09-01)
by: Deckert Martin, et al.
Published: (2016-09-01)
Eco-friendly aqueous spinning of robust and porous carbon nanotube/graphene hybrid microelectrodes: The graphene oxide size effect
by: Kang Cheng, et al.
Published: (2024-06-01)
by: Kang Cheng, et al.
Published: (2024-06-01)
Flexible Parylene C-Based RRAM Array for Neuromorphic Applications
by: Jo-Eun Kim, et al.
Published: (2022-01-01)
by: Jo-Eun Kim, et al.
Published: (2022-01-01)
Impermeable and Elastic Polydimethylsiloxane Film by Parylene‐Caulking for Inflatable Soft Devices
by: Satoshi Konishi, et al.
Published: (2025-04-01)
by: Satoshi Konishi, et al.
Published: (2025-04-01)
Similar Items
-
Parylene-Based Flexible Microelectrode Arrays for the Electrical Recording of Muscles and the Effect of Electrode Size
by: Bong-Jun Choi, et al.
Published: (2020-10-01) -
Immunohistological responses in mice implanted with Parylene HT – ITO ECoG devices
by: Miklós Madarász, et al.
Published: (2023-08-01) -
Microfabrication of Embedding a Flexible Parylene-Based Microelectrode Array within Body-on-a-Chip
by: Tatsuya Omaki, et al.
Published: (2017-08-01) -
ECoG Dual Context Network for Brain Machine Interfaces
by: Shunya Nagashima, et al.
Published: (2025-01-01) -
Handcrafted Electrocorticography Electrodes for a Rodent Behavioral Model
by: Nishat Tasnim, et al.
Published: (2016-08-01)