Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression

The paper presents the notion of high dimensionality—in the results—that could change the exergy and energy characteristics of the two-pass solar collector. To examine the energetic aspect of the collector, two different types of absorber plate surfaces were chosen: one that is smooth and one with t...

Full description

Bibliographic Details
Published in:Energies
Main Author: Alok Dhaundiyal
Format: Article
Language:English
Published: MDPI AG 2023-03-01
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/5/2461
_version_ 1850093016971214848
author Alok Dhaundiyal
author_facet Alok Dhaundiyal
author_sort Alok Dhaundiyal
collection DOAJ
container_title Energies
description The paper presents the notion of high dimensionality—in the results—that could change the exergy and energy characteristics of the two-pass solar collector. To examine the energetic aspect of the collector, two different types of absorber plate surfaces were chosen: one that is smooth and one with triangular fins. Both designs have two-pass and wooden baffles underneath their absorber plates. The induced air blower was used for the forced convection of air. To examine the attribute of the data, the least angle regression (LARS) algorithm was used to find a new exergy model without overfitting the data. The second law efficiency dropped by 18.92% for the given models of the solar collector when the air flow rate surged further from 10.10 g·s<sup>−1</sup> to 12.10 g·s<sup>−1</sup>, whereas the energy efficiency showed contradictory behaviour for the given range of air flow rate. It increased by 3% in the first half of the rise in the air flow rate, and on the other hand, a jump of 8% was recorded in the energy efficiency with a rise in the air flow rate by 19.80%. The addition of wooden baffles in the second passage of the flat plate two-pass collector increased the entropy generation due to air friction by 200%, albeit it dropped by 50% at 12.10 g·s<sup>−1</sup>. Upon increasing the air stream rate from 8.10 g·s<sup>−1</sup> to 12.10 g·s<sup>−1</sup>, the exergy destruction rate at the front finned surface of the two-pass solar air collector receded by 5.49–8.76%, and at the same time, it elevated for the rear passage provided with the wooden baffles. However, it decreased for both the front and rear surfaces of the solar air collector, as the air flow rate increased by 24.69%.
format Article
id doaj-art-e2a7c0fa16f64cb8a25b5891531bcaac
institution Directory of Open Access Journals
issn 1996-1073
language English
publishDate 2023-03-01
publisher MDPI AG
record_format Article
spelling doaj-art-e2a7c0fa16f64cb8a25b5891531bcaac2025-08-20T00:08:08ZengMDPI AGEnergies1996-10732023-03-01165246110.3390/en16052461Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle RegressionAlok Dhaundiyal0Centre for Energy Research, Konkoly Thege M. út 29-33, 1121 Budapest, HungaryThe paper presents the notion of high dimensionality—in the results—that could change the exergy and energy characteristics of the two-pass solar collector. To examine the energetic aspect of the collector, two different types of absorber plate surfaces were chosen: one that is smooth and one with triangular fins. Both designs have two-pass and wooden baffles underneath their absorber plates. The induced air blower was used for the forced convection of air. To examine the attribute of the data, the least angle regression (LARS) algorithm was used to find a new exergy model without overfitting the data. The second law efficiency dropped by 18.92% for the given models of the solar collector when the air flow rate surged further from 10.10 g·s<sup>−1</sup> to 12.10 g·s<sup>−1</sup>, whereas the energy efficiency showed contradictory behaviour for the given range of air flow rate. It increased by 3% in the first half of the rise in the air flow rate, and on the other hand, a jump of 8% was recorded in the energy efficiency with a rise in the air flow rate by 19.80%. The addition of wooden baffles in the second passage of the flat plate two-pass collector increased the entropy generation due to air friction by 200%, albeit it dropped by 50% at 12.10 g·s<sup>−1</sup>. Upon increasing the air stream rate from 8.10 g·s<sup>−1</sup> to 12.10 g·s<sup>−1</sup>, the exergy destruction rate at the front finned surface of the two-pass solar air collector receded by 5.49–8.76%, and at the same time, it elevated for the rear passage provided with the wooden baffles. However, it decreased for both the front and rear surfaces of the solar air collector, as the air flow rate increased by 24.69%.https://www.mdpi.com/1996-1073/16/5/2461exergysolar air collectorenergyentropyregression analysisair
spellingShingle Alok Dhaundiyal
Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
exergy
solar air collector
energy
entropy
regression analysis
air
title Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
title_full Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
title_fullStr Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
title_full_unstemmed Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
title_short Thermo-Statistical Investigation of the Solar Air Collector Using Least Angle Regression
title_sort thermo statistical investigation of the solar air collector using least angle regression
topic exergy
solar air collector
energy
entropy
regression analysis
air
url https://www.mdpi.com/1996-1073/16/5/2461
work_keys_str_mv AT alokdhaundiyal thermostatisticalinvestigationofthesolaraircollectorusingleastangleregression