Peak Current Control in Discontinuous Conduction Mode of Boost PFC

Peak current control is widely used in Boost power factor correction( PFC) converter, but mainly used in continuous conduction mode (CCM). Since the sinusoidal peak fitting curve is used in the discontinuous conduction mode (DCM), the average curve of a current cannot be sinusoidal and the power fac...

Full description

Bibliographic Details
Published in:Kongzhi Yu Xinxi Jishu
Main Authors: YAN Kaige, LIU Kun, PAN Yingying, GAN Yiyang
Format: Article
Language:Chinese
Published: Editorial Office of Control and Information Technology 2019-01-01
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2096-5427.2019.01.011
Description
Summary:Peak current control is widely used in Boost power factor correction( PFC) converter, but mainly used in continuous conduction mode (CCM). Since the sinusoidal peak fitting curve is used in the discontinuous conduction mode (DCM), the average curve of a current cannot be sinusoidal and the power factor (PF) is low. In this paper, based on the calculated current characteristics in the DCM mode, a peak fitting curve was derived, and it can be used to improve the power factor. Moreover, to a certain extent, it constitutes a closed-loop control of the inductor current, which improves the reliability of the circuit. By PSIM software simulation and prototype experiment, the control method was proved to be effective.