Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes
For chronic applications of flexible neural implants, e.g., intracortical probes, the flexible substrate material has to encapsulate the electrical conductors with a long-term stability against the saline environment of the neural tissue. The biocompatible polymer polyimide is often used for this pu...
| Published in: | Micromachines |
|---|---|
| Main Authors: | , , , |
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2021-10-01
|
| Subjects: | |
| Online Access: | https://www.mdpi.com/2072-666X/12/11/1279 |
| _version_ | 1851831938265907200 |
|---|---|
| author | Andreas Schander Julia Morais Gancz Marcel Tintelott Walter Lang |
| author_facet | Andreas Schander Julia Morais Gancz Marcel Tintelott Walter Lang |
| author_sort | Andreas Schander |
| collection | DOAJ |
| container_title | Micromachines |
| description | For chronic applications of flexible neural implants, e.g., intracortical probes, the flexible substrate material has to encapsulate the electrical conductors with a long-term stability against the saline environment of the neural tissue. The biocompatible polymer polyimide is often used for this purpose. Due to its chemical inertness, the adhesion between two polyimide layers is, however, a challenge, which can lead to delamination and, finally, to short circuits. The state-of-the-art method to improve the adhesion strength is activating the polyimide surface using oxygen reactive ion etching (O<sub>2</sub> RIE). However, the influence of the process variations (etching time, bias power) on the long-term stability is still unclear. Therefore, we establish a test method, where the aging of a gold interdigital structure embedded in two polyimide layers and immersed in saline solution is accelerated using an elevated temperature, mechanical stress and an electrical field. A continuous measurement of a leakage current is used to define the failure state. The results show that the variation of the O<sub>2</sub> RIE plasma process has a significant effect on the long-term stability of the test samples. Comparing the two different plasma treatments 0.5 min at 25 W and 1 min at 50 W, the long-term stability could be increased from 20.9 ± 19.1 days to 44.9 ± 18.9 days. This corresponds to more than a doubled lifetime. An ideal solution for the delamination problem is still not available; however, the study shows that the fine-tuning of the fabrication processes can improve the long-term stability of chronically implanted neural electrodes. |
| format | Article |
| id | doaj-art-e36ceaf2b2ad4b6a863dcd528ed0f8a2 |
| institution | Directory of Open Access Journals |
| issn | 2072-666X |
| language | English |
| publishDate | 2021-10-01 |
| publisher | MDPI AG |
| record_format | Article |
| spelling | doaj-art-e36ceaf2b2ad4b6a863dcd528ed0f8a22025-08-19T22:31:46ZengMDPI AGMicromachines2072-666X2021-10-011211127910.3390/mi12111279Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural ElectrodesAndreas Schander0Julia Morais Gancz1Marcel Tintelott2Walter Lang3Institute for Microsensors, -Actuators and -Systems (IMSAS), University of Bremen, 28359 Bremen, GermanyInstitute for Microsensors, -Actuators and -Systems (IMSAS), University of Bremen, 28359 Bremen, GermanyInstitute for Microsensors, -Actuators and -Systems (IMSAS), University of Bremen, 28359 Bremen, GermanyInstitute for Microsensors, -Actuators and -Systems (IMSAS), University of Bremen, 28359 Bremen, GermanyFor chronic applications of flexible neural implants, e.g., intracortical probes, the flexible substrate material has to encapsulate the electrical conductors with a long-term stability against the saline environment of the neural tissue. The biocompatible polymer polyimide is often used for this purpose. Due to its chemical inertness, the adhesion between two polyimide layers is, however, a challenge, which can lead to delamination and, finally, to short circuits. The state-of-the-art method to improve the adhesion strength is activating the polyimide surface using oxygen reactive ion etching (O<sub>2</sub> RIE). However, the influence of the process variations (etching time, bias power) on the long-term stability is still unclear. Therefore, we establish a test method, where the aging of a gold interdigital structure embedded in two polyimide layers and immersed in saline solution is accelerated using an elevated temperature, mechanical stress and an electrical field. A continuous measurement of a leakage current is used to define the failure state. The results show that the variation of the O<sub>2</sub> RIE plasma process has a significant effect on the long-term stability of the test samples. Comparing the two different plasma treatments 0.5 min at 25 W and 1 min at 50 W, the long-term stability could be increased from 20.9 ± 19.1 days to 44.9 ± 18.9 days. This corresponds to more than a doubled lifetime. An ideal solution for the delamination problem is still not available; however, the study shows that the fine-tuning of the fabrication processes can improve the long-term stability of chronically implanted neural electrodes.https://www.mdpi.com/2072-666X/12/11/1279polyimideneural interfacesflexible implantslong-term stabilityinterdigital electrode arrayelectrical insulation stability |
| spellingShingle | Andreas Schander Julia Morais Gancz Marcel Tintelott Walter Lang Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes polyimide neural interfaces flexible implants long-term stability interdigital electrode array electrical insulation stability |
| title | Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes |
| title_full | Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes |
| title_fullStr | Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes |
| title_full_unstemmed | Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes |
| title_short | Towards Long-Term Stable Polyimide-Based Flexible Electrical Insulation for Chronically Implanted Neural Electrodes |
| title_sort | towards long term stable polyimide based flexible electrical insulation for chronically implanted neural electrodes |
| topic | polyimide neural interfaces flexible implants long-term stability interdigital electrode array electrical insulation stability |
| url | https://www.mdpi.com/2072-666X/12/11/1279 |
| work_keys_str_mv | AT andreasschander towardslongtermstablepolyimidebasedflexibleelectricalinsulationforchronicallyimplantedneuralelectrodes AT juliamoraisgancz towardslongtermstablepolyimidebasedflexibleelectricalinsulationforchronicallyimplantedneuralelectrodes AT marceltintelott towardslongtermstablepolyimidebasedflexibleelectricalinsulationforchronicallyimplantedneuralelectrodes AT walterlang towardslongtermstablepolyimidebasedflexibleelectricalinsulationforchronicallyimplantedneuralelectrodes |