The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
Purpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All paramet...
| Published in: | Journal of Current Ophthalmology |
|---|---|
| Main Authors: | , , , , |
| Format: | Article |
| Language: | English |
| Published: |
Wolters Kluwer Medknow Publications
2024-04-01
|
| Subjects: | |
| Online Access: | https://journals.lww.com/10.4103/joco.joco_78_24 |
| _version_ | 1850010315859689472 |
|---|---|
| author | Seyed Mohsen Rafizadeh Ghazal Ghochani Masoud Khorrami-Nejad Rawshan Jumah Hesam Hashemian |
| author_facet | Seyed Mohsen Rafizadeh Ghazal Ghochani Masoud Khorrami-Nejad Rawshan Jumah Hesam Hashemian |
| author_sort | Seyed Mohsen Rafizadeh |
| collection | DOAJ |
| container_title | Journal of Current Ophthalmology |
| description | Purpose:
To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure.
Methods:
In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All parameters were measured by the Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device.
Results:
The study included 35 eyelids of the right eyes of 35 patients with dermatochalasis who underwent UEB, with a mean age of 56.9 ± 8.9 (range, 40–75) years. With a Bonferroni corrected significance level of P < 0.001 to account for multiple comparisons, significant increases were observed in the first applanation (A1) and second applanation (A2) times and the highest concavity (HC) time following the UEB surgery. Intraocular pressure (IOP) and biomechanical-compensated IOP (bIOP) also showed a significant increase. Other corneal biomechanical parameters did not show significant differences following the UEB procedure (P > 0.001).
Conclusions:
UEB surgery resulted in significant changes in A1 and A2 applanation times, HC time, IOP, and bIOP. These findings suggest that altered eyelid pressure after UEB surgery can impact specific corneal biomechanical properties. It is advisable for practitioners to evaluate postoperative IOP measurement carefully in patients undergoing UEB surgery due to its potential impact on corneal biomechanical properties. |
| format | Article |
| id | doaj-art-e77fffa99c6f49f18b7b89b1f2bb04e2 |
| institution | Directory of Open Access Journals |
| issn | 2452-2325 |
| language | English |
| publishDate | 2024-04-01 |
| publisher | Wolters Kluwer Medknow Publications |
| record_format | Article |
| spelling | doaj-art-e77fffa99c6f49f18b7b89b1f2bb04e22025-08-20T00:44:33ZengWolters Kluwer Medknow PublicationsJournal of Current Ophthalmology2452-23252024-04-0136219019710.4103/joco.joco_78_24The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis STSeyed Mohsen RafizadehGhazal GhochaniMasoud Khorrami-NejadRawshan JumahHesam HashemianPurpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All parameters were measured by the Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device. Results: The study included 35 eyelids of the right eyes of 35 patients with dermatochalasis who underwent UEB, with a mean age of 56.9 ± 8.9 (range, 40–75) years. With a Bonferroni corrected significance level of P < 0.001 to account for multiple comparisons, significant increases were observed in the first applanation (A1) and second applanation (A2) times and the highest concavity (HC) time following the UEB surgery. Intraocular pressure (IOP) and biomechanical-compensated IOP (bIOP) also showed a significant increase. Other corneal biomechanical parameters did not show significant differences following the UEB procedure (P > 0.001). Conclusions: UEB surgery resulted in significant changes in A1 and A2 applanation times, HC time, IOP, and bIOP. These findings suggest that altered eyelid pressure after UEB surgery can impact specific corneal biomechanical properties. It is advisable for practitioners to evaluate postoperative IOP measurement carefully in patients undergoing UEB surgery due to its potential impact on corneal biomechanical properties.https://journals.lww.com/10.4103/joco.joco_78_24corneacorneal biomechanicscorvis stdermatochalasisupper eyelid blepharoplasty |
| spellingShingle | Seyed Mohsen Rafizadeh Ghazal Ghochani Masoud Khorrami-Nejad Rawshan Jumah Hesam Hashemian The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST cornea corneal biomechanics corvis st dermatochalasis upper eyelid blepharoplasty |
| title | The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST |
| title_full | The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST |
| title_fullStr | The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST |
| title_full_unstemmed | The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST |
| title_short | The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST |
| title_sort | effect of upper eyelid blepharoplasty on corneal biomechanical parameters measured by corvis st |
| topic | cornea corneal biomechanics corvis st dermatochalasis upper eyelid blepharoplasty |
| url | https://journals.lww.com/10.4103/joco.joco_78_24 |
| work_keys_str_mv | AT seyedmohsenrafizadeh theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT ghazalghochani theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT masoudkhorraminejad theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT rawshanjumah theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT hesamhashemian theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT seyedmohsenrafizadeh effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT ghazalghochani effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT masoudkhorraminejad effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT rawshanjumah effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst AT hesamhashemian effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst |