The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST

Purpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All paramet...

Full description

Bibliographic Details
Published in:Journal of Current Ophthalmology
Main Authors: Seyed Mohsen Rafizadeh, Ghazal Ghochani, Masoud Khorrami-Nejad, Rawshan Jumah, Hesam Hashemian
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2024-04-01
Subjects:
Online Access:https://journals.lww.com/10.4103/joco.joco_78_24
_version_ 1850010315859689472
author Seyed Mohsen Rafizadeh
Ghazal Ghochani
Masoud Khorrami-Nejad
Rawshan Jumah
Hesam Hashemian
author_facet Seyed Mohsen Rafizadeh
Ghazal Ghochani
Masoud Khorrami-Nejad
Rawshan Jumah
Hesam Hashemian
author_sort Seyed Mohsen Rafizadeh
collection DOAJ
container_title Journal of Current Ophthalmology
description Purpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All parameters were measured by the Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device. Results: The study included 35 eyelids of the right eyes of 35 patients with dermatochalasis who underwent UEB, with a mean age of 56.9 ± 8.9 (range, 40–75) years. With a Bonferroni corrected significance level of P < 0.001 to account for multiple comparisons, significant increases were observed in the first applanation (A1) and second applanation (A2) times and the highest concavity (HC) time following the UEB surgery. Intraocular pressure (IOP) and biomechanical-compensated IOP (bIOP) also showed a significant increase. Other corneal biomechanical parameters did not show significant differences following the UEB procedure (P > 0.001). Conclusions: UEB surgery resulted in significant changes in A1 and A2 applanation times, HC time, IOP, and bIOP. These findings suggest that altered eyelid pressure after UEB surgery can impact specific corneal biomechanical properties. It is advisable for practitioners to evaluate postoperative IOP measurement carefully in patients undergoing UEB surgery due to its potential impact on corneal biomechanical properties.
format Article
id doaj-art-e77fffa99c6f49f18b7b89b1f2bb04e2
institution Directory of Open Access Journals
issn 2452-2325
language English
publishDate 2024-04-01
publisher Wolters Kluwer Medknow Publications
record_format Article
spelling doaj-art-e77fffa99c6f49f18b7b89b1f2bb04e22025-08-20T00:44:33ZengWolters Kluwer Medknow PublicationsJournal of Current Ophthalmology2452-23252024-04-0136219019710.4103/joco.joco_78_24The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis STSeyed Mohsen RafizadehGhazal GhochaniMasoud Khorrami-NejadRawshan JumahHesam HashemianPurpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 months after UEB surgery. All parameters were measured by the Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device. Results: The study included 35 eyelids of the right eyes of 35 patients with dermatochalasis who underwent UEB, with a mean age of 56.9 ± 8.9 (range, 40–75) years. With a Bonferroni corrected significance level of P < 0.001 to account for multiple comparisons, significant increases were observed in the first applanation (A1) and second applanation (A2) times and the highest concavity (HC) time following the UEB surgery. Intraocular pressure (IOP) and biomechanical-compensated IOP (bIOP) also showed a significant increase. Other corneal biomechanical parameters did not show significant differences following the UEB procedure (P > 0.001). Conclusions: UEB surgery resulted in significant changes in A1 and A2 applanation times, HC time, IOP, and bIOP. These findings suggest that altered eyelid pressure after UEB surgery can impact specific corneal biomechanical properties. It is advisable for practitioners to evaluate postoperative IOP measurement carefully in patients undergoing UEB surgery due to its potential impact on corneal biomechanical properties.https://journals.lww.com/10.4103/joco.joco_78_24corneacorneal biomechanicscorvis stdermatochalasisupper eyelid blepharoplasty
spellingShingle Seyed Mohsen Rafizadeh
Ghazal Ghochani
Masoud Khorrami-Nejad
Rawshan Jumah
Hesam Hashemian
The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
cornea
corneal biomechanics
corvis st
dermatochalasis
upper eyelid blepharoplasty
title The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
title_full The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
title_fullStr The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
title_full_unstemmed The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
title_short The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST
title_sort effect of upper eyelid blepharoplasty on corneal biomechanical parameters measured by corvis st
topic cornea
corneal biomechanics
corvis st
dermatochalasis
upper eyelid blepharoplasty
url https://journals.lww.com/10.4103/joco.joco_78_24
work_keys_str_mv AT seyedmohsenrafizadeh theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT ghazalghochani theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT masoudkhorraminejad theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT rawshanjumah theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT hesamhashemian theeffectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT seyedmohsenrafizadeh effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT ghazalghochani effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT masoudkhorraminejad effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT rawshanjumah effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst
AT hesamhashemian effectofuppereyelidblepharoplastyoncornealbiomechanicalparametersmeasuredbycorvisst